4XLFN5H IHUHQF H*XLGH SCPI Co mmand Summa ry The following conventions are used for SCPI command syntax for remote interface programming: • Square brackets ( [ ] ) indicate o ptional keywords o r parameters. • Braces ( { } ) enclose parameter choices with in a command string.
Scan Measurement Commands ( see page 226 in the User’s Gu ide ) MEASure :TEMPerature? { TCoup le |RTD|FRTD|THERmi stor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < s.
Scan Configuration Commands ( see page 226 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger : SOU Rce {B U S | IMMediate |EXTernal|ALA Rm1|ALARm2|ALARm3|ALARm4 .
Scanning With an External Instrument ( see page 239 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXT ernal| TIMer } :SOURce? TRIGger .
Temperature Configuration Commands ( see page 219 in the User’s Gu ide ) CONFigure :TEMPerature { TCoupl e |RTD|FRTD|THERmis tor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,.
Voltage Configuration Commands ( see page 223 in the User’s Gu ide ) CONFigure :VOLTage:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONF.
Resistance Configuration Commands ( see page 224 in the User’s Gu ide ) CONFigure :RESistance [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) C.
Current Configuration Commands ( see page 224 in the User’s Gu ide ) Valid only on channels 21 and 22 on the 34901A mul tiplexer module. CONFigure :CURRent:DC [{< range >| AUTO |MIN|M AX|DEF} .
Frequency a nd Period Configuration Commands ( see page 214 in the User’s Gu ide ) CONFigure :FREQuency [{< range >| AUTO |MIN|MA X|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_li.
Mx+B Scalin g Commands ( see page 244 in the User’s Gu ide ) CALCulate :SCALe:GAIN < gain >[ ,( @ < ch_list >)] :SCALe:GAIN? [( @ < ch_list >)] :SCALe:OFFSet < offset >[,( @ .
Digital Input Commands ( see page 255 in the User’s Gu ide ) Ch 01 DIO (L SB) Ch 0 2 DIO (MSB ) Ch 03 Totalizer Ch 04 DAC Ch 05 DAC CONFigure:DIGital:BYTE ( @ < scan_list >) CONFigure? [( @ &l.
Switch Control Commands ( see page 259 in the User’s Gu ide ) ROUTe :CLOSe ( @ < ch_list >) :CLOSe:EXCLusive ( @ < ch_list >) :CLOSe? ( @ < ch_lis t >) ROUTe :OPEN ( @ < ch_list.
System-Related Commands ( see page 264 in the User’s Gu ide ) SYSTem :DATE < yyyy > , < mm > ,< dd > :DATE? :TIME < hh >,< mm >,< ss.
Status System Commands ( see page 286 in the User’s Gu ide ) *STB? *SRE < enable _value > *SRE? STATus :QUEStionable:CONDition? :QUEStionable[:EVENt]? :QUEStionable:ENABle < ena ble_value &.
Service-Related Commands ( see page 294 in the User’s Gu ide ) INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled? DIAGnostic :DMM:CYCLes? :DMM:CYCLes:CLEar (1|2|3} DIAGnostic :RELay:CYCLes? [( @ < ch_list >)] :RELay:CYCLes:CLEar [( @ < ch_list >)] *RST SYSTem:PRESet SYSTem:CPON {100|200|300|ALL } SYSTem:VERSion? *TST? IEEE 488.
Agilent 34901A 20-Channel Multiplexer ( see page 164 in the User’s Gu ide ) Agilent 34902A 16-Channel Multiplexer ( see page 166 in the User’s Gu ide ) 16.
Agilent 34903A 20-Channel Act uator ( see page 168 in the User’s Gu ide ) Agilent 34904A 4x8 Matrix ( see page 170 in the User’s Gu ide ) 17.
Agilent 34905A/6A Dual 4- Channel RF Multiplexers ( see page 172 in the User’s Gu ide ) Agilent 34908A 40-Channel Single-Ended Mul tiplexer ( see page 174 in the User’s Gu ide ) 18.
Agilent 34907A Mult ifunction Module ( see page 176 in the User’s Gu ide ) 19.
Factory Reset State The table below shows the state of the instrument after a FACTORY RESET from the Sto/Rcl menu or *RST command from the remote interface.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Agilent Technologies 34970A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Agilent Technologies 34970A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Agilent Technologies 34970A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Agilent Technologies 34970A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Agilent Technologies 34970A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Agilent Technologies 34970A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Agilent Technologies 34970A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Agilent Technologies 34970A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.