Owner' s Manua l World-Clas s Aut o Securit y T M Av antGu ar d I I.
.
Table of Contents EXTREMELY IMPORTANT NOTICE . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 WARNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 How to Operate the Premier™ Remote Control . . . . . . . . .
EXTREME LY IMPORTANT NOTICE If the AvantGuard II’s control unit is removed from the vehicle for any reason, the supplied RED jumper wire MUST BE CONNECTED to pins #8 and #11 of the PIGTAIL connecto r . WARNING 1. The AvantGuard II is designed to be used only on a gasoline-powered, fuel-injected vehicle with automatic transmission.
How to Operate the Premier™ 4x8 Remote Control The Premier 4-button/8-channel, 4-billion code remote control provides incredibly high digital code security to give you the ultimate in protection against professional thieves using digital code scanners.
How to Arm the System with the Remote Control 1. Press remote control button I/channel 1. 2. Simultaneousl y , several actions will take place to confirm remote disarming: • The siren will chirp twice providing audible confirmation from a distance. (If you prefe r, you can turn off the chirp acknowledgements (see page 7 for details).
Valet Mode Whenever your vehicle is to be serviced, washed or valet parked, you must use the valet mode to disarm the system and override its Smart AutoArming feature. How to Enable V alet Mode 1. Insert your key and turn the ignition to the “ON” position.
Smart AutoArming™ If you forget to arm your system with the remote control, it will arm itself automat - ically 30 seconds after the vehicle doors are closed. (The Multicolor LED will blink green for visual confirmation of the 30-second Smart AutoArming countdown).
Prior Intrusion Attempt Alert If the alarm sounded while you were awa y , when you remotely disarm the system will issue three chirps and three flashes of the parking lights. You’ll note that the Multicolor LED will blink in red 1-7 times, pause for one second then repeat the cycle four more time.
b. To turn the chirps on : Flick the switch to its latched position, then back to center . c. Y ou will hear 3 chirps to confirm chirp muting or restoration. 7. Turn the ignition off . Y ou will hear 3 chirps to confirm exiting of program mode. One-Cycle Chirp Muting: This is particularly useful when parking in a quiet residential area.
Remote Engine Starting How to Remotely Start the Engine Remote control button II (channel 2) will remotely start (or shut down) the engine: 1. With the remote control microswitch in the up position, press and hold button II (channel 2) until you see your vehicle’s parking lights flash twice.
How to Engage AutoStart 1. Make sure that the gas tank is at least half full. To conserve battery powe r , make sure the air conditione r, radio and all other accessories are turned off. 2. Insert your ignition key and turn the switch to the “ ON ” position.
How to Program Your AvantGuard II NOTE: A Quick Programming Guide is on pages 17-19. However, if you are programming the system for the first time, we strongly recommend that you follow the detailed instructions in the specific sections that follow before attempting to use the guide.
How to Set Your Own Personalized Siren Sound Y ou can program a unique code of siren chirps to recognize your system at a distance.. Y our Personalized Siren Sound will consist of any combination of eight or less dot (short) and/or dash (long) siren pulsating sounds.
How to Adjust Sensitivity of the Optional OmniSensor You can easily increase or decrease the sensitivity of the optional OmniSensor any time, any place, without tools and without even knowing where to sensor is mounted. To change sensitivity of the optional OmniSenso r, use the following procedure: 1.
How to Enable/Disable AutoLock and AutoUnLock The system automatically locks your car doors 5 seconds after you shift the trans - mission into Drive. Conversel y , the doors automatically unlock after you turn the ignition off. To disable or re-enable this feature, use the following procedure: 1.
How to Set the Smart AutoArming Entry Delay Entry delay is programmable from 1 to 59 seconds (factory preset to 15 seconds). For security reasons, the entry delay should be just enough time for you to open the door and turn on the ignition. To set a new entry dela y , use the following procedure: 1.
b. Flip the switch to its latched position, then back to center . You will hear 3 chirps . c. Tap the switch to its momentary position 1 time . d. Flip the switch to its latched position, then back to center . You will hear 1 chirp . e. Flip the switch to its latched position, then press button II on your remote.
Quick Programming Guide Once you are familiar with the AvantGuard II programming procedures, you may use this quick guide to make programming changes. IMPORTANT: DO NOT use this guide unless you have programmed the AvantGuard II before.
Programmable Feature Parameter Action Step Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Personalized Siren Sound Any pattern of up to 8 dots and/or dashes Flick switch to M M L C MMM L C Number of chirps 2.
Programmable Featur e Parameter Action Step Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 AutoLock and AutoUnLock Enable Flick switch to M L C M M L C L C Number of chirps 1 2 3 Disable Flick switch to M L .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Clifford AvantGuard II c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Clifford AvantGuard II - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Clifford AvantGuard II, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Clifford AvantGuard II va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Clifford AvantGuard II, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Clifford AvantGuard II.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Clifford AvantGuard II. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Clifford AvantGuard II ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.