Manuel d'utilisation / d'entretien du produit 15454 du fabricant Cisco Systems
Aller à la page of 726
Americas Headquarters Cisco Systems, In c. 170 West Tasman Drive San Jose, CA 951 34-1706 USA http://www.ci sco.com Tel: 408 526-4000 800 553-NETS (638 7) Fax: 408 527-0883 Cisco ONS 1 5454 Reference Manual Produ ct and Documentat ion R elease 7 .
THE SPECIFICATION S AND INFORMATION REGARDING TH E PRODUCTS IN THIS MANUAL ARE SUBJECT T O CHANGE WITH OUT NOTICE. ALL STATEMENTS , INFORMATION , AND RECOMMEN DATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESEN TED WITHOUT WARRANTY OF ANY KIND, EX PRESS OR IMPLIED.
iii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 CONTENTS About this Manual xxxix Revision History xxxix Document Objectives xli Audience xli Document Organization xlii Related Documentation xl.
Contents iv Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 1.5.5.2 MiniBNC Insertion and Removal To ol 1-26 1.5.6 SMB EIA 1-27 1.5.7 AMP Champ EIA 1-28 1.5.8 UBIC-V EIA 1-32 1.5.9 UBIC-H EIA 1-33 1.5.10 EIA Replacement 1-37 1.6 Coaxial Cable 1-37 1.
Contents v Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 CHAPTER 2 Common Control Cards 2-1 2.1 Common Control Card Overview 2-1 2.1.1 Cards Summary 2-1 2.1.2 Card Compatibility 2-3 2.1.3 Cross-Connect Card Compatibility 2-3 2.2 TCC2 Card 2-6 2.
Contents vi Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 CHAPTER 3 Electrical Cards 3-1 3.1 Electrical Card Overview 3-1 3.1.1 Card Summary 3-1 3.1.2 Card Compatibility 3-3 3.2 EC 1-12 Car d 3-4 3.2.1 EC1-12 Slots and Connecto rs 3-4 3.2.2 EC1-12 Faceplate and Block Diagram 3-4 3.
Contents vii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 3.8.3 DS3-12E and DS3N-12E Card-Level Indicators 3-23 3.8.4 DS3-12E and DS3N-12E Port-Level Indicators 3-24 3.9 DS3XM-6 Card 3-24 3.9.1 DS3XM-6 Slots and Connectors 3-24 3.9.2 DS3XM-6 Facepl ate and Block Diagram 3-24 3.
Contents viii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 4.7 OC12 IR/STM4 SH 1310-4 Card 4-15 4.7.1 OC12 IR/STM4 SH 1310-4 Card-Level Indicators 4-17 4.7.2 OC12 IR/STM4 SH 1 310-4 Port-Level Indicators 4-17 4.8 OC48 IR 1310 Card 4-17 4.8.1 OC48 IR 1310 Card-Level Indicators 4-18 4.
Contents ix Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 4.19 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards 4-46 4.19.1 OC192SR1/STM64IO Sho rt Reach and OC19 2/STM64 Any Reach Card-Lev el Indicators 4-49 4.19.2 OC192SR1/STM64IO Short Reach a nd OC-192/STM-64 Any Reach Port-Level Indicators 4-49 4.
Contents x Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 5.7.1 STS-24c Restriction 5-17 5.7.2 G1K-4 Compatibility 5-18 5.7.3 G1K-4 Card-Level Indicators 5-18 5.7.4 G1K-4 Port-Level Indicators 5-18 5.8 ML100T-12 Card 5-19 5.8.1 ML100T-12 Card-L evel Indicators 5-20 5.
Contents xi Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 6.2.2.2 SW -LCAS 6-5 6.2.2.3 Distance Extension 6-5 6.2.2.4 Differential Delay Features 6-6 6.2.2.5 Interoperability Features 6-6 6.2.3 Link Integrity 6-6 6.2.4 Link Recovery 6-7 6.3 FC_MR-4 Card Application 6-7 6.
Contents xii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 8.5.1.2 Node View Card Shortcuts 8-10 8.5.1.3 Node View Tabs 8-10 8.5.2 Network View 8-11 8.5.2.1 Network View Tabs 8-12 8.5.2.2 CTC Node Colors 8-13 8.5.2.3 DCC Links 8-13 8.5.2.4 Link Consolidation 8-13 8.
Contents xiii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 11.2.3 Circuit States 11-7 11.2.4 Circuit Protection Types 11-9 11.2.5 Circuit Information in the Edit Circuit Window 11-10 11.3 Cross-Connect Card Bandwidth 11-12 11.4 Portless Transmux 11-15 11.
Contents xiv Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 11.21 VLAN Management 11-44 11.22 Server Trails 11-44 CHAPTER 12 SONET Topologies and Upgrad es 12-1 12.1 SONET Rings and TCC2/TCC2P Cards 12-1 12.2 Bidirectional Line Switched Rings 12-2 12.
Contents xv Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Ena bled 13-20 13.3 Provisionable Patchcords 13-22 13.4 Routing Table 13-24 13.5 External Firewalls 13-25 13.6 Open GNE 13-27 13.7 TCP/IP and OSI Networking 13-29 13.
Contents xvi Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 14.2 LCD Alarm Counts 14-1 14.3 Alarm Information 14-2 14.3.1 Viewing Alarms With Each Node’s Time Zone 14-4 14.3.2 Controlling Alarm Display 14-4 14.3.3 Filtering Alarms 14-4 14.3.4 Viewing Alarm-Affected Circuits 14-5 14.
Contents xvii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 15.5.3 DS1-14 and DS1N-14 Card Performance Monitoring Parameters 15-16 15.5.3.1 DS-1 Facility Data Link Performance Monitoring 15-18 15.5.4 DS3-12 and DS3N-12 Card Performance Monitoring Parameters 15-18 15.
Contents xviii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 16.5 SNMP Message Types 16-4 16.6 SNMP Management Information Bases 16-5 16.6.1 IETF-Standard MIBs for the ONS 15454 16-5 16.6.2 Proprietary ONS 1 5454 MIBs 16-6 16.6.3 Generic Threshold and Performance Monitoring MIBs 16-7 16.
Contents xix Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 A.1.2 Configurations A-1 A.1.3 Cisco Transport Controller A-2 A.1.4 External LAN Interface A-2 A.1.5 TL1 Craft Int erface A-2 A.1.6 Modem Interface A-2 A.1.7 Alarm Inter face A-2 A.1.8 EIA Interface A-3 A.
Contents xx Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 A.6.4 OC12 LR/STM4 LH 1310 Card Specifications A-28 A.6.5 OC12 LR/STM4 LH 1550 Card Specifications A-29 A.6.6 OC12 IR/STM4 SH 1310-4 Specifications A-30 A.6.7 OC48 IR 1 310 Card Specifications A-31 A.
Contents xxi Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 C.2 Card Default Settings C-2 C.2.1 Configuration Defaults C-2 C.2.2 Threshold Defaults C-3 C.2.3 Defaults by Card C-4 C.2.3.1 DS-1 Card Default Settings C-4 C.2.3.2 DS1/E1-56 Card Default Settings C-7 C.
Contents xxii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01.
FI GU RE S xxiii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Figure 1-1 Cisco ONS 15454 ANSI Dimensions 1-4 Figure 1-2 Mounting an ONS 15454 in a Rack 1-5 Figure 1-3 The ONS 15454 Front Door 1.
Figure s xxiv Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Figure 1-31 Crossover Cable 1-52 Figure 1-32 Managing Cable s on the Front Panel 1-53 Figure 1-33 Fiber Capacity 1-5 3 Figure 1-34 Tie-.
Figures xxv Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Figure 3-12 DS3XM-12 Faceplate and Block Diagram 3-30 Figure 4-1 OC3 IR 4/STM1 SH 1310 Faceplate and Block Dia gram 4-6 Figure 4-2 OC3IR.
Figure s xxvi Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Figure 5-8 ML100X-8 Faceplate and Block Diagram 5-22 Figure 5-9 ML1000-2 Faceplate 5-24 Figure 5-10 CE-100T-8 Faceplate and Block Diagr.
Figures xxvii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Figure 11-9 Secondary Source s and Destinations 11-27 Figure 11-10 Alternate Paths fo r Virtual Path Protection Segments 11-29 Figure .
Figure s xxviii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Figure 13-1 IP Scenario 1: CTC and ONS 15454s on Same Subnet 13-3 Figure 13-2 IP Scenario 2: CTC and ONS 15454 Nodes Con nected to a .
Figures xxix Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Figure 13-36 OSI/IP Scenario 5: GNE Without an OSI DCC Connection 13-56 Figure 13-37 OSI/IP Scenario 6: IP OSS, OSI DCN, ONS GNE, OSI D.
Figure s xxx Cisco ONS 15454 Reference Manual, R7.0 78-17191-01.
TABLES xxxi Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 T able 1 Cisco ONS 15454 Refe rence Manual Chapters 1-xlii T able 1-1 EIA Types Compatible with the 15454-SA-ANSI Only 1-15 T able 1-2 E.
Tables xxxii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 T able 1-28 BITS External Timing Pin Assignments 1-67 T able 1-29 LAN Pin As signments 1-68 T able 1-30 Craft In terface Pin Assignments.
Tables xxxiii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 T able 3-6 DS1/E1-56 Card-Level Indicators 3-12 T able 3-7 DS3-12 and DS3N-12 Card-Level Indicators 3-14 T able 3-8 DS3/EC1-48 Slot Re.
Tables xxxiv Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 T able 5-3 E100T-12 Card-Level Indicators 5-5 T able 5-4 E100T-12 Port-Level Indicators 5-5 T able 5-5 E100T-G Card-Level Indicators 5-7.
Tables xxxv Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 T able 8-6 Node View Card Port Colors an d Service States 8-9 T able 8-7 Node View Tabs and Subtabs 8-10 T able 8-8 Network View Tabs an.
Tables xxxvi Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 T able 12-4 Comparison of the Protection Sche mes 12-18 T able 12-5 Slot 5, 6, 12, and 13 Upgrade Options 12-23 T able 12-6 Upgrade Opti.
Tables xxxvii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 T able 15-6 DS1-14 and DS1N-14 Card PMs 15-17 T able 15-7 DS3-12 and DS3N-12 Card PMs 15-19 T able 15-8 DS3-12E and DS3N-12E Card PMs .
Tables xxxviii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 T able A-2 Individual Card Power Requirements A-6 T able A-3 Card Temperature Ranges and P roduct Names A-8 T able B-1 ONS 15454 Servi.
xxxix Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 About this Manual Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
xl Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 About this Man ual April 2008 Added a note in the User Passw ord, Login, and Access Policies section in the Security chapter . Updated note on protect ion switching in Link Capacit y Adjustment section in Circuits an d T unnel s chapter .
xli Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 About this Manual Document Objectives This manual pro vides reference inform ation for the Cisco ONS 15454 .
xlii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 About this Man ual Document Organization T able 1 Cisco ONS 15454 Ref er ence Manual Chapters T itle S ummary Chapter 1, “Sh elf and Back plan.
xliii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 About this Manual Related Documentation Use the Cisco ONS 15454 Ref er ence Manual with the follo wing referenced publications: • Cisco ONS 15454 Pr ocedur e Guide Provides pr ocedures to install, turn u p, provision, an d maintain a Cisco ONS 15454 nod e and network.
xliv Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 About this Man ual Document Conventions This publication u ses the follo wing con ventions: Note Means reader take note . Notes contain helpful suggestions or references to material n ot cov ered in the document.
xlv Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 About this Manual War ni n g IMPORT ANT SAFETY INSTRUCTIONS This warning symbol means danger . Y ou are in a situation that could cause bodily injury .
xlvi Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 About this Man ual Avvertenza IMPORT ANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo.
xlvii Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 About this Manual.
xlviii Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 About this Man ual Avis o INSTRUÇÕES IMPORT ANTES DE SEGURANÇA Este símbolo de aviso significa perigo.
xlix Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 About this Manual.
l Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 About this Man ual Obtaining Documentation and Submitting a Service Request Obtaining Optical Networking Information This section contains inf ormation that is specif ic to optical network ing products.
CH A P T E R 1-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 1 Shelf and Backplane Hardware Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
1-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.1 1.1 Overview Caution Unused card slots should be filled with a detect able f iller card (Cisco P/N 15454-FILLER) or a non-detectable f iller card (Ci sco P/N 15454-BLANK).
1-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.2 1.2 Rack Installation • United States: National Fire Protection Associatio n (NFP A) 70; U nited Stat es National Electrical Code • Canada: Cana dian Electrical Code, Part I, CS A C22.
1-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.2 1.2.1 Reversible Mountin g Bracket Figur e 1 -1 Cisco ONS 15454 ANSI Dimensions 1.
1-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.2 1.2.2 Mounting a Single Node 1.2.2 Mounting a Single Node Mounting the ONS 15454 in a rack requir es a minimum of 18.5 inches (469.9 mm) of v ertical rack space and one additional inch (25.
1-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.3 1.2.4 ONS 15454 Bay Assembly 1.2.4 ONS 15454 Bay Assembly The Cisco ONS 15454 Bay Asse mbly si mplifies ordering and installing the ONS 15454 because it allows you to order shelf assemblies preins talled in a sev en -foot (2.
1-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.3 1.3 Front Door Figur e 1 -4 Cisco ONS 15454 Deep Door . The ONS 15454 door lock s with a pinned he x key that ships with the ONS 15454. A b utton o n the right side of the shelf assembly releases the do or .
1-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.3 1.3 Front Door Figur e 1 -5 ONS 15454 Fr ont Door Gr ound Strap Figure 1-6 sho ws how to remo ve th e front door .
1-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.3 1.3 Front Door Figur e 1 -6 Removing the ONS 15454 F ront Door An erasable label is pasted on the inside of the front door ( Figure 1 -7 ).
1-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.4 1.4 B ackplane Covers Figur e 1 -7 Fr ont-Door Er asable Label Note The front door label also includes the Class I and Class 1M laser warning ( F igure 1-8 ).
1-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.4 1.4.1 Lower Backplane Cover Figure 1 -9 Backplane Cov ers 1.
1-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.4 1.4.2 Rear Cover 1.4.2 Rear Cover The ONS 15454 has an optional clear plast ic rear c over . T hi s c le a r p la st ic cove r p r ovi de s a dd it io n al protection for the cables and connectors on the backplane.
1-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.4 1.4.3 Alarm Interface Panel Figur e 1 -12 Installing the Plas tic Rear Cov er with Spacers 1.4.3 Alarm Interface Panel The AIP is locat ed abov e the al arm contacts o n the lo wer secti on of the backpla ne.
1-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5 Electrical Interface Assemblies Y o u can replace the AIP on an in-s ervice system without af fecting tr af fic (e xcept Ethernet traff ic on nodes running a software r elease earl ier than R elease 4.
1-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.1 EIA Installation 1.5.1 EIA Installation Optional EIA backplane co ver s are typically preinstall ed when ordered wi th the ONS 15454. A minimal amount of assembly might be required w hen EIAs are ordered separately from t he ONS 15454.
1-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.2 EIA Configurations T able 1-2 sho ws the EIA types supported b y both the 154 54-SA-ANSI and the 1545 4-SA-HD (high density) shel f assemblies.
1-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.3 BNC EIA 1.5.3 BNC EIA The ONS 15454 BNC EIA suppor ts 24 DS-3 circuits on each side of the ONS 15454 (24 tr ansmit and 24 recei ve connector s).
1-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.3 BNC EIA type. Use RG-59/U cable to connect to the ONS 15 454 BNC EIA. These c ables are recommended to connect to a pat ch panel and are desig ned for long runs.
1-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.4 High-Density BNC EIA 1.5.3.2 BNC Insertion and Removal Tool Due to the lar ge number of BNC connector s on the hi gh-density BNC EIA, you mig ht require a special tool for inserting and remo ving BNC EIAs ( Figu re 1-14 ).
1-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.5 MiniBNC EIA Figure 1 -15 High-Density BNC Backplane fo r Use in 1:N Prot ection Schemes The EIA side marked “ A” hosts 48 pairs of BNC connectors.
1-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.5 MiniBNC EIA • DS3/EC1-48 MiniBNCs support a v ailable high -density cards in unprotected and 1:N protection (where N < 2) protection groups.
1-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.5 MiniBNC EIA Figure 1 -16 MiniBNC Backplane for Use in 1:N Pr otection Sc hemes.
1-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.5 MiniBNC EIA T able 1-4 and Ta b l e 1 - 5 sho w the J-labelling and correspondi ng card ports for a shelf assembly configured with lo w-density electrical cards.
1-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.5 MiniBNC EIA T able 1-6 and Ta b l e 1 - 7 show the J-labelling and correspondi ng card ports for a shelf assembly confi gured with high-density 48-p ort DS-3/EC-1electrical cards.
1-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.5 MiniBNC EIA T able 1 -6 J-Labelli ng P or t Assignments f or a Sh elf Configur ed with Hi gh-D.
1-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.5 MiniBNC EIA 1.5.5.2 MiniBNC Inserti on and Removal Tool Due to the lar ge number of MiniBNC connect ors on the Mini BNC EIA, you mi ght require a special tool for inserting and r emoving Mi niBNC EIAs ( Figure 1-17 ).
1-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1. 5.6 SMB EIA Figur e 1 -17 MiniBNC Insertion an d Remo v al T ool This tool can be obtained with P/N 227-T1000 fro m: Amphenol USA (www .
1-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.7 AMP Champ EIA Figur e 1 -18 SMB EIA Backplane The SMB EIA has 84 transmit and 84 receiv e connect ors on each side of the ONS 15454 for a total of 168 SMB connectors (84 ci rcuits).
1-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.7 AMP Champ EIA Because each DS1-14 card supports 14 DS-1 ports, on ly 56 pins (28 pairs) of the 64-pi n connector are used. Prepare one 56-wire c able fo r each D S-1 facility installed.
1-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.7 AMP Champ EIA T able 1-9 sho ws the pin assignments for the A MP Champ connectors on the ONS 15454 AMP Champ EIA for a shield ed DS-1 cable.
1-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.7 AMP Champ EIA When using DS-1 AMP Champ cabl es, you must equip t he ONS 15454 with an AMP Champ connector EIA on each side of the backplane where DS-1 cabl e s will terminate.
1-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.8 UBIC-V EIA 1.5.8 UBIC-V EIA UBIC-V EIAs are attached to the shelf a ssembly b ackplane to provide up to 112 transmit and recei ve connections through 16 SCSI conn ectors per side (A and B).
1-33 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.9 UBIC-H EIA The UBIC-V she et metal c ov ers use the sam e screw holes as the stand ard sheet m.
1-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.9 UBIC-H EIA Y ou can install UBIC-Hs on one or both sides of the ONS 1545 4. As you face the rear of t he ONS 15454 shelf assembly , the right side is the A side (154 54-EIA-UBICH-A) and the left si de is the B side (15454-EIA-UBICH-B).
1-35 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.5 1.5.9 UBIC-H EIA Ta b l e s 1-13 and 1- 14 show the J-labell ing and corresponding card ports for a shelf assembly conf igured with high-density 48 -port DS-3/EC- 1 or 56-port DS-1 electrical cards.
1-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.5 1.5.9 UBIC-H EIA If you are inst alling UBIC-H EIAs after the sh elf assembly i s installed, plu g the UBIC-H EIA into the backplane. The UBIC-H backplane must replace the standard sheet metal cover to provide access to the cable connectors.
1-37 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.6 1.5.10 EIA Replacement The A and B sides each host 16 high-density , 50-pin SCSI co nnectors. The A-side maps to Slots 1 through 6 an d the B-side maps to Slots 12 th rough 17.
1-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.7 1.7.2 Electrical Inte rface Adapters Caution Alway s use the supplied ESD wristband when wo rking with a po wered ONS 15454. Plug the wristband cable into the ESD jack located on th e lower -right outside edge of the shelf assemb ly .
1-39 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.8 1.8 UBIC-V Cables 1.8 UBIC-V Cables Note Cisco Systems announced the end-of- sale and end-of-life dates for the Cisco ONS 15454 MSPP Univ ersal BackPlane Interface Adapter, V ertical Or ientation (UB IC-V), and its DS1 and DS3 Cables.
1-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.8 1.8 UBIC-V Cables T able 1 -16 UBIC-V DS-1 SCSI Connector Pin Out Port SCS I Pin SCSI Pin Port #1 1 .
1-41 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.8 1.8 UBIC-V Cables Figure 1 -24 UBIC-V DS-1 Cable Schematic Diagr am T able 1-17 sho ws the UBIC-V DS-1 T ip/Ring color coding.
1-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.8 1.8 UBIC-V Cables T able 1-18 identif ies the UBIC-V SCSI connecto r pin assignments for the DS-3/EC-1 cables as referenced from the EIA backpl ane to t he SCSI connecto r .
1-43 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.8 1.8 UBIC-V Cables Figure 1-25 shows the UBIC-V DS-3/ EC- 1 cable schematic diagra m.
1-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.9 1.9 UBIC-H Cables Figur e 1 -25 UBIC-V DS-3/EC- 1 Cable Sc hematic Diagram 1.9 UBIC-H Cables The UBIC-H EIA is designed to support DS-1, DS-3, o r EC-1 signals.
1-45 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.9 1.9 UBIC-H Cables T o support DS-3 or EC-1 signals, select the DS-3/EC-1 UBIC-H cable assembly (part n umber 15454-CADS3-H-<lengt h>). DS-1 cables for the UBIC-H hav e a maximum supported distance of 65 5 feet (199.
1-46 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.9 1.9 UBIC-H Cables Figure 1 -26 Cable Connector Pins T able 1-19 identif ies the UBIC-H SCSI connecto r pin assignments for the DS-1 cables as referenced from the EIA backplane to the SCSI connector .
1-47 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.9 1.9 UBIC-H Cables Figure 1 -27 UBIC-H DS-1 Cable Schematic Diagr am T able 1-20 sho ws the UBIC-H DS-1 T ip/Ring color coding.
1-48 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.9 1.9 UBIC-H Cables T able 1-21 identif ies the UBIC-H SCSI connecto r pin assignments for the DS-3/EC-1 cables as referenced from the EIA backpl ane to t he SCSI connecto r .
1-49 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.9 1.9 UBIC-H Cables Figure 1-28 shows the UBIC-H DS-3/ EC- 1 cable schematic diagra m #5 17 42 #11 FGn.
1-50 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.10 1.10 Ethernet Cables Figur e 1 -28 UBIC-H DS-3/EC- 1 Cable Sc hematic Diagram 1.10 Ethernet Cables Ethernet cables use RJ-45 connectors, and are straight-t hrough or crossov er , depending on what is connected to them.
1-51 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.10 1.10 Ethernet Cables Figure 1-29 show s the pin locations on 100 BaseT connector . Figur e 1 -29 1 0 0Bas eT Connector Pins Figure 1-30 show s the straight-through Ethernet cabl e schematic.
1-52 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.11 1.11 Cable Routing and Ma nagement Figure 1-31 shows the crosso ver Ethernet cable schematic. Use a c rossov er cable when connecting to a switch or hub .
1-53 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.11 1.11.1 Fiber Management Figur e 1 -32 Managing Cables on the F ro nt P anel 1.11.1 Fiber Management The univ ersal cable router is desi gned to route f iber jumpers out of b oth sides of the shelf.
1-54 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.11 1.11.2 Fiber Management Using the Tie-Down Bar Plan your fiber size according to the number of card s/ports installed in each side of the shelf. For exam ple, if your port combinat ion requires 36 f ibers , 3 mm (0.
1-55 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.12 1.11.4 DS-1 Twisted-Pair Cable Mana gement 1.11.4 DS-1 Twisted-Pair Cable Management Connect twisted pair/DS -1 cables to SMB EIAs on the ONS 15454 backplane using cable connectors and DS-1 EIAs (baluns) .
1-56 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.12 1.12.1 Wire-Wrap and Pin Connections Figure 1 -36 AEP Block Diagram Each AEP alarm input port ha s provis ionable label and se verity . The alarm inputs ha ve opto coupler isolation.
1-57 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.12 1.12.1 Wire-Wrap and Pin Con nections Figure 1-38 is a circuit diagram of the al arm inputs (Inputs 1 and 32 are sho wn in the e xample). Figur e 1 -38 Alar m Input Circuit Diagr am T able 1-25 lists the connections to the external alarm sources.
1-58 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.12 1.12.1 Wire-Wrap and Pin Connections Figure 1-39 is a circuit diagram of the al arm outputs (Outpu ts 1 and 16 are sho wn in the e xample).
1-59 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.12 1.12.1 Wire-Wrap and Pin Con nections Figur e 1 -39 Alar m Output Cir cuit Diagram Use the pin numbers in T able 1-26 to connect to the external elements being switched by e xternal alarms.
1-60 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.13 1.13 Filler Card 1.13 Filler Card Filler cards are designed to occu py empty multiserv ice and AIC-I slots in the Ci sco ONS 15454 (Slot s 1 – 6, 9, and 12 – 17).
1-61 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.14 1.14 Fan-Tray Assembly Figur e 1 -40 Det ectable Filler Car d F aceplat e 1.14 Fan-Tray Assembly The fan-tray assembly is located at the bottom of the ONS 154 54 bay assembly .
1-62 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.14 1.14.1 Fan Speed an d Power Requirements The front of the fan-tray assembly has an LCD screen that provides sl ot- and port-le vel information for all ONS 15454 card slots, including the number o f Critical, Majo r , and Minor alarms.
1-63 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.15 1.14.3 Air Filter 1.14.3 Air Filter The ONS 15454 contains a reusable air f i lter; Model 15454-FTF2, t hat is installed either be neath the fan-tray assembly o r in the optional e xternal fi lter brackets.
1-64 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.16 1.16 Alar m, Timing, LAN , and Craft P in Connectio ns Figur e 1 -41 Ground P osts on the ONS 15454 Backplane 1.16 Alarm, Timing, LAN, and Craft Pin Connections Caution Alway s use the supplied ESD wristband when wo rking with a po wered ONS 15454.
1-65 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.16 1.16 Alarm, Timin g, LAN, and Craft Pin Connec tions Figure 1 -42 ONS 15454 Backplane Pi nouts (Release 3.
1-66 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.16 1.16.1 Alarm Contact Connections Figur e 1 -43 ONS 15454 Backplane Pinouts 1.
1-67 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.16 1.16.2 Timing Connections V isual and audible alarms are typicall y wired to trigger an alarm light or bell at a central alarm collection point when the correspon ding contacts are closed.
1-68 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.17 1.16.4 TL1 Craft Interface Inst allation 1.16.4 TL1 Craft Interface Installation Y ou can use the c.
1-69 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.17 1.17.1 Card Slo t Requirements Figur e 1 -44 Instal ling Card s in the ONS 15454 1.17.1 Card Slot Requirements The ONS 15454 shelf assembly has 17 card slots numbered sequentially from le ft to right.
1-70 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.17 1.17.1 Card Slot Requirements Note Protection schemes and EIA types ca n af fect slot compatibility . T able 1-32 lists the number of ports, l ine rates, connector options, and conn ector locations f or ONS 15454 optical and el ectrical cards.
1-71 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.17 1.17.1 Card Slo t Requirements DS3/EC1-48 48 2.147 Gbps SMB or BNC Backplane EC1-12 12 51.
1-72 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.17 1.17.2 Card Replacement 1.17.2 Card Replacement T o replace an ONS 15454 card with another card of the same type, you do not need to make any chang es to the data base; remo ve th e old card an d replace it wi th a ne w card.
1-73 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.18 1.18 Software and Hardware Compatibility 1.18 Software and Hardware Compatibility T able 1-33 sho ws ONS 15454 softw are and hardware comp atibility for nodes co nfigu red with XC or XCVT cards for Releases 4.
1-74 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.18 1.18 Softwar e and Hardware Compatibility ML1000-2 All Fully compatible Fully compatible Fully comp.
1-75 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.18 1.18 Software and Hardware Compatibility T able 1-34 sho ws ONS 15454 softwa re and hardware compatibil ity for systems conf igured with XC10G or XC-VXC-10G cards for Releases 4.
1-76 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.18 1.18 Softwar e and Hardware Compatibility DS3-12 2 All Fully compatib le Fully compatible Partially.
1-77 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf and Bac kplane Hardware 1.18 1.18 Software and Hardware Compatibility If an upgrade is required f or compatibility , contac t the Cisco T e chnical Assistance Center (T A C). For contact information, go to http://www .
1-78 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 1 Shelf an d Backplane Hardware 1.18 1.18 Softwar e and Hardware Compatibility.
CH A P T E R 2-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 2 Common Control Cards Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
2-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.1 2. 1.1 Ca rds Summ ary T able 2-1 Common Control Card F unctions Card Description For Additional Information.
2-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.1 2.1.2 Card Compatibility 2.1.2 Card Compatibility T able 2-2 lists the Cisco T ransport Controller (CTC ) software release compatibi lity for each common-control card.
2-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.1 2.1.3 Cross-Connect Card Compatibility T able 2-4 lists the cross-connect card compatibility for each electrical card. F or electrical card software compatiblilty , see T able 3-2 on page 3-3 .
2-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.1 2.1.3 Cross-Connect Card Compatibility T able 2-6 lists the cross-connect card co mpatibility for each Ethernet card. F or Ethernet card software compatibility , see T able 5-2 on page 5-3 .
2-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.2 2.2 TCC2 Card T able 2-7 lists the cross-connect card co mpatibility for each stor age ar ea networ k (SAN) card. For SAN card software compati bility , see the “6.
2-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.2 2.2.1 TCC2 Card Functionality Figur e 2-1 TCC2 Card F ace plate and Bloc k Diagram 2.2.1 TCC2 Card Functionality The TCC2 card supports multichannel, hig h-le vel data link control (HDLC) processing for the DCC.
2-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.2 2.2.2 TCC2 Card-Level In dicators The TCC2 card also originates and terminates a cell bus carried o ver the mod ule. The cell b us supports links between an y two cards in t he node, which is e ssential for peer -to-peer commun ication.
2-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.2 2.2.3 Network-Level Indicators 2.2.3 Network-Level Indicators T able 2-9 describes the six netw ork-le vel LEDs on t he TCC2 faceplate. T able 2-8 TCC2 Card-L evel Ind icator s Card-Level LEDs Definition Red F AIL LED This LED is on during reset.
2-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.3 2.2.4 Power-Level Indica tors 2.2.4 Power-Level Indicators T able 2-10 describes the two po wer -le vel LEDs on the TCC2 f aceplate. 2.3 TCC2P Card Note For hardware specifications, see the “ A.
2-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.3 2.3.1 TCC2P Functionality Figur e 2-2 TCC2P F acepl at e and Block Diagr am 2.3.1 TCC2P Functionality The TCC2P card support s multichannel, high-le vel data link control (HDLC) processing for the DCC.
2-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.3 2.3. 1 TC C2P Funct ionality The TCC2P card also originates a nd terminates a cell bus carried o ver the modul e. The cell b us supports links between an y two cards in t he node, which is e ssential for p eer-to-peer communication.
2-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.3 2. 3.2 TCC2 P Card -Level Indicators card, taking about 15 to 20 minutes to co mplete.
2-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.4 2.3.4 Power-Level Indica tors 2.3.4 Power-Level Indicators T able 2-13 describes the two po wer -le vel LEDs on the TCC2P f aceplate. 2.4 XCVT Card Note For hardware specifications, see the “ A.
2-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.4 2.4.1 XCVT Functionality Figure 2-3 XCVT F ace pl ate and Block Diagr am 2.4.1 XCVT Functionality The STS-1 switch matrix on the XCVT card consists of 288 bidirecti onal ports and adds a VT mat rix that can manage up to 336 bidirectional VT1 .
2-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.4 2.4.2 VT Mapping The XCVT card works with the TCC2/TCC2P cards to maintain connections and set up cross-connects within the node. The cross-conn ect cards (such as the XCVT a nd XC10G), installed in Slots 8 and 10, are required to operat e the ONS 15454.
2-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.4 2.4.3 XCVT Hosting DS3XM-6 or DS3XM-12 2.4.3 XCVT Hosting DS3XM-6 or DS3XM-12 A DS3XM card can demultiple x (map do wn to a lo wer rate) M13-mapped DS-3 si gnals into 28 DS-1s that are then mapped to VT1.
2-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.5 2.5 XC10G Card 2.5 XC10G Card Note For hardware specifications, see the “ A.4.4 XC10G Card Specif ications” section on page A-12 . The 10 Giga bit Cross Connec t (XC10G) card establis hes connections at the STS-1 and VT lev els.
2-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.5 2.5.1 XC10G Functionality Figure 2-5 X C1 0G F aceplate and Bloc k Diagram 2.5.1 XC10G Functionality The XC10G card manag es up to 672 bidi rectional VT1.5 por ts and 1152 bidir ectional STS-1 ports.
2-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.5 2.5.2 VT Mapping Caution Do not operate the ONS 15 454 with only one X CVT or XC10G card. T wo cross-connect cards of the same type (either tw o XCVT or two XC10G car ds) must alwa ys be installed.
2-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.5 2.5.3 XC10G Hosting DS3XM-6 or DS3XM-12 2.5.3 XC10G Hosting DS3XM-6 or DS3XM-12 A DS3XM card can demultiple x (map do wn to a lo wer rate) M13-mapped DS-3 si gnals into 28 DS-1s that are the n mapped t o VT1.
2-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.6 2.5.5 XCVT/XC10G/XC-VXC-10G Compatibility 2.5.5 XCVT/XC10G/XC-VXC-10G Compatibility The XC10G and XC-VXC-10G card s support the same features as the XCVT card.
2-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.6 2.6.1 XC-VXC-10G Functionality Figur e 2-7 X C-VX C-1 0G F ace plat e and Block Diagr am 2.6.1 XC-VXC-10G Functionality The XC-VXC-10G card manages up to 1152 b idirectional high-ord er STS-1 ports.
2-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.6 2.6.1 XC-VXC-10G Functionality At the STS level (high-order cro ss- connect), the XC-VXC-10G is alw ays non-b.
2-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.6 2.6.2 VT Mapping Figur e 2-8 X C-VX C-1 0G Cross-Connect Matr ix 2.6.2 VT Mapping The VT structure is designed to transport an d switch payloads belo w the DS-3 rate.
2-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.6 2.6.3 XC-VXC-10G Hosting DS3XM-6 or DS3XM-12 2.6.3 XC-VXC-10G Hosting DS3XM-6 or DS3XM-12 A DS3XM card can demultiple x (map do wn to a lo wer rate) M13-mapped DS-3 si gnals into 28 DS-1s that are then mapped to VT1.
2-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.7 2.6.5 XC-VXC-10G Compatibility 2.6.5 XC-VXC-10G Compatibility The XC-VXC-10G card supports the same featur es as the XC10G card. Either the XC 10G or XC-VXC-10G card is required fo r OC-192, OC3-8, and O C12-4 operation and OC-48 AS operatio n.
2-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.7 2.7.1 AIC-I Card-Level In dicators Figur e 2-9 AIC-I F aceplat e and Block Diagr am 2.7.1 AIC-I Card-Level Indicators T able 2-20 describes th e eight card-le vel LEDs on the AIC -I card face plate.
2-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.7 2.7.2 Exte rnal Alarms and Controls 2.7.2 External Alarms and Controls The AIC-I card provi des input/output alarm contact closures. Y ou can define up to twelve ex ternal alarm inputs and 4 e xternal alarm inpu ts/outputs (user conf igurable).
2-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.7 2.7.3 Orderwire The output contacts can be pro visioned to close on a trigger or to close manually .
2-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.7 2.7.4 Power Monitoring The AIC-I supports selecti ve dual tone multifrequen cy (DTMF) diali ng for telephon y connecti vity , which causes one AIC-I card or all ONS 15 454 AIC -I cards on the orderwire subnetw ork to “ring.
2-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 2 Common Control Cards 2.7 2.7.6 Data Communications Channel 2.7.6 Data Communications Channel The DCC features a dedicated data channel of 576 kbps (D4 to D12 b ytes) between two nodes in an ONS 15454 network.
CH A P T E R 3-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 3 Electrical Cards This chapter describes Cisco ONS 15454 electrical card features and functions. For i nstallation and card turn-up procedures, refer to the Cisco ONS 15454 Pr ocedur e Guide .
3-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.1 3.1.1 Card Summary T able 3-1 Cisco ONS 15454 Electrical Car ds Card Name Description For Additional Information EC1-12 The EC1-12 card pro vides 12 T elcordia-compliant, GR-253 STS-1 electrical ports per card.
3-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.1 3.1.2 Card Compatibility 3.1.2 Card Compatibility T able 3-2 lists the CTC software compatibil ity for each electrical card. See T able 2-4 on page 2-4 for a list of cross-connect cards that are compatible with ea ch electrical card.
3-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.2 3.2 EC1-12 Card 3.2 EC1-12 Card Note For hardware specifications, see the “ A.5.1 EC1-12 Card Specifi cations” section on page A-15 . The EC1-12 card pro vides 12 T elcordia-compliant, GR-253 STS-1 electrical ports per card.
3-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.2 3.2.3 EC1-12 Hosted by XCVT, XC10G, or XC-VXC-10G Figur e 3-1 EC1 -12 Faceplat e and Block Diagr am 3.
3-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.3 3.2.5 EC1-12 Port-Level Indicators 3.2.5 EC1-12 Port-Level Indicators Y ou can obtain the status of the EC1-12 card ports b y using the LCD screen o n the ONS 15454 fan tray .
3-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.3 3.3.2 DS1-14 and DS1N-14 Slot Compatibility If you use the DS1N-14 as a st andard DS-1 card in a 1:1 protection group, y ou can install the DS1N -14 card in Slots 1 to 6 or 12 to 17 on the ONS 15 454.
3-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.3 3.3.4 DS1-14 and DS1N-14 Hosted by XCVT, XC10G, or XC-VXC-10G Figur e 3-3 DS1N-14 F aceplate and Bloc k Diagram 3.3.4 DS1-14 and DS1N-14 Hosted by XCVT, XC10G, or XC-VXC-10G All 14 VT1.
3-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.4 3.3.6 DS1-14 a nd DS1N-14 Port-Level Indicato rs 3.3.6 DS1-14 and DS1N-14 Port-Level Indicators Y ou can obtain the status of the D S1-14 and DS1N-14 card por ts by using the LCD screen on the ONS 15454 fan -tray assembly .
3-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.4 3.4.2 DS1/E1-56 Faceplate an d Block Diagra m Note The DS1/E1-56 card supports an err orless softw are-initia ted cross-c onnect card sw itch when used in a shelf equipped with XC-VXC-10G and TCC2/TCC2P cards.
3-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.4 3.4.3 DS1/E1-56 Card-Level Indicators Figur e 3-4 DS1/E1 -56 Faceplat e and Block Diagr am 3.4.3 DS1/E1-56 Card-Level Indicators The DS1/E1-56 card has three card-lev el LED indicators ( Ta b l e 3 - 6 ).
3-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.5 3.4.4 DS1/E1-56 Port-Level Indicators 3.4.4 DS1/E1-56 Port-Level Indicators Y ou can obtain the status of the D S1/E1-56 card ports b y using the LCD scr een on the ONS 15454 fan-tray assembly .
3-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.5 3.5.1 DS3-12 a nd DS3N-12 Slots and Connec tors 3.5.1 DS3-12 and DS3N-12 Slots and Connectors Y ou can install the DS3-12 or DS3N-12 card in Sl ots 1 to 6 or 12 to 17 on t he ONS 15454.
3-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.5 3.5.3 DS3-12 and DS3N-12 Card-Level Indicators Figure 3-6 sho ws the DS3N-12 faceplate and a blo ck diagram of the card. Figur e 3-6 DS3N-12 F aceplate and Bloc k Diagram 3.
3-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.6 3.5.4 DS3-12 a nd DS3N-12 Port-Level Indicato rs 3.5.4 DS3-12 and DS3N-12 Port-Level Indicators Y ou can find the status o f the 12 DS3-12 and 12 DS3 N-12 card ports by using the LCD screen on the ONS 15454 fan -tray assembly .
3-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.6 3.6.2 DS3/EC1-48 Faceplate and Block Diagra m Caution Do not install a D S3/EC1-48 card in Slots 1 or 2 if you hav e installed an MXP_2.5G _10G card in Slot 3. Like wise, do not inst all a DS3/EC1-48 card in S lots 16 or 17 if you ha v e installed an MXP_2.
3-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.6 3.6.3 DS3/EC1-48 Card-Level Indicators Figur e 3-7 DS3/EC1 -48 Faceplat e and Block Diagr am 3.6.3 DS3/EC1-48 Card-Level Indicators The DS3/EC1-48 card has three card-le v el LED indicators ( Ta b l e 3 - 9 ).
3-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.7 3.6.4 DS3/EC1-48 Port-Level Indicators 3.6.4 DS3/EC1-48 Port-Level Indicators Y ou can obtain the status of the D S3/EC1-48 card ports b y using the LCD screen on the ONS 15 454 fan-tray assembly .
3-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.7 3.7.1 DS3i -N-12 Slots and Con nectors Figur e 3-8 DS3i-N-12 F aceplate and Bloc k Diagram The follo wing list su.
3-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.8 3.7.2 DS3i-N-12 Card-Level Indicators 3.7.2 DS3i-N-12 Card-Level Indicators T able 3-10 describes the three LEDs on the DS3i-N-12 car d faceplate.
3-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.8 3.8.1 DS3-12E an d DS3N-12E Slots and Connec tors • FEBE monitoring • FEA C status and loop code detection .
3-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.8 3.8.2 DS3-12E Faceplate an d Block Diagr am Figur e 3-9 DS3-12E F aceplat e and Block Diagr am Figure 3-10 show s the DS3N-12E facep late and a block diagram of the card.
3-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.8 3.8.3 DS3-12E and DS3N-12E Card-Level Indicators Figur e 3-1 0 DS3N-12E F ace plate and Bloc k Diagram 3.8.3 DS3-12E and DS3N-12E Card-Level Indicators T able 3-11 describes the three card-le vel LEDs on the DS3-12E and DS3N-12E card faceplate s.
3-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.9 3.8.4 DS3-12E and DS3N-12E Port-Level Indicators 3.8.4 DS3-12E and DS3N-12E Port-Level Indicators Y ou can find the status of the DS3-1 2E and DS3N-12E card ports by usi ng the LCD screen on the ONS 15454 fan-tray assemb ly .
3-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.9 3.9.3 DS3XM-6 Host ed By XCVT, XC10G or XC-VXC-10G Figur e 3-1 1 DS3XM-6 F ace plat e and Block Diagr am 3.9.3 DS3XM-6 Hosted By XCVT, XC10G or XC-VXC-10G The DS3XM-6 card works in co njunction with the XCVT card.
3-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.9.5 DS3XM-6 Port-Level Indicators 3.9.5 DS3XM-6 Port-Level Indicators Y ou can find the status o f the six DS3XM-6 card ports b y using the LCD screen on the O NS 15454 fan-tray assembly .
3-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.10.2 Ported Mode The DS3XM-12 supports thr ee different backplane throug hput config urations: • STS-48 when an XC10G or XC-VXC-10G card is used . This config uration supports the OC-48 rate in any slot.
3-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.10.5 Protection Modes 3.10.5 Protection Modes The DS3XM-12 card supports 1 :1 and 1:N protection gro ups, where N <= 5. Ho we ver , N <= 7 if one of the follo wing condition s is true: • Only portless connection s are used.
3-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.10.7 DS3XM-12 Slots and Connectors 3.10.7 DS3XM-12 Slots and Connectors The DS3XM-12 card can be used with BNC, SMB, SCSI (UBIC), or MiniBNC EIA connectors. The card can be installed in Slots 1 to 6 or 12 to 17.
3-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.10.9 DS3XM-12 Card-Level I ndicators Figur e 3-12 DS3XM-12 Face p lat e and Bloc k Diagr am 3.10.9 DS3XM-12 Card-Level Indicators T able 3-15 describes the three card-lev el LEDs on the DS3XM-12 card faceplate.
3-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.10.10 DS3XM-12 Port-Level Indicators 3.10.10 DS3XM-12 Port-Level Indicators Y ou can find the status of the twelve DS3XM-12 card po rts by using the LCD screen on th e ONS 15454 fan-tray assembly .
3-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 3 Electrical Cards 3.10 3.10.1 0 DS3XM-12 Port-Level Indicators.
CH A P T E R 4-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 4 Optical Cards Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
4-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.1 4.1 Optical Card Overview • 4.20 Optical Card S FPs and XFPs, page 4-49 4.1 Optical Card Overview Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly .
4-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.1 4.1.1 Card Summary OC12 LR/STM4 LH 1550 The OC12 LR/STM4 LH 1550 card provides o ne long-range OC-12 port and operates at 1550 nm. See the “4.6 OC12 LR/STM4 LH 1550 Card” section on page 4-13 .
4-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.1 4.1.2 Card Compatibility Note The Cisco OC3 IR/STM1 SH, OC12 IR/STM4 SH, and OC48 IR/STM16 SH interf ace optics, all working at 1 310 nm, are optimized for the most widely used SMF-28 f iber, a vailable from man y suppliers.
4-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.2 4.2 OC3 IR 4/STM1 SH 1310 Card 4.2 OC3 IR 4/STM1 SH 1310 Card Note For hardwa re specifications, see the “ A.6.1 OC3 IR 4/STM1 SH 1310 Card Specifications” section on page A-25 .
4-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.2 4.2 OC3 IR 4/STM1 SH 1310 Card The OC3 IR 4/STM1 SH 1310 card provid es four intermediate o r short range SONET/SDH OC-3 ports compliant with ITU-T G.707 , ITU-T G.957, and T e lcordia GR-253-CORE.
4-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.3 4.2.1 OC3 IR 4/STM1 SH 1310 Card-Level Indicators The OC3 IR 4/STM1 SH 1310 card detects loss of signal (LOS), loss of frame (LOF), loss of pointer (LOP), line-layer alarm indication signal (AI S-L), and line-layer remote defect indi cation (RDI-L) conditions.
4-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.3 4.3 OC3 IR/STM1 SH 1310-8 Card War ni ng The laser is on when th e optical card is boote d. The port does not have to be in service for the laser to be on. Statement 293 Figure 4-2 sho ws the card faceplate and block diagram.
4-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.4 4.3.1 OC3 IR/STM1 SH 1310-8 Card-Level Indica tors 4.3.1 OC3 IR/STM1 SH 1310-8 Card-Level Indicators T able 4-4 describes the three card-le vel LEDs on the eight-port OC3 IR/STM1 SH 1310-8 card .
4-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.4 4.4.1 OC12 IR/STM4 SH 1310 Card-Level Indicators Figur e 4-3 OC12 IR/STM4 SH 131 0 F acepla te and Blo ck Dia gra m .
4-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.5 4.4.2 OC12 IR/STM 4 SH 1310 Port-Level Indicators 4.4.2 OC12 IR/STM4 SH 1310 Port-Level Indicators Y ou can find the status of the O C-12 IR/STM4 SH 1310 card port b y using the LCD screen on the ONS 15454 fan -tray assembly .
4-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.5 4.5.1 OC12 LR/STM4 LH 1310 Card-Level Indicators Figur e 4-4 OC12 LR/STM4 LH 131 0 F aceplat e and Block Diagr am Y .
4-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.6 4.5.2 OC12 LR/STM4 LH 1310 Port-Level Indicators 4.5.2 OC12 LR/STM4 LH 1310 Port-Level Indicators Y ou can find the status of the OC12 LR/STM 4 LH 1310 card port b y using the LCD screen o n the ONS 15454 fan-tray assemb ly .
4-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.6 4.6.1 OC12 LR/STM4 LH 1550 Card-Level Indicators Figur e 4-5 OC12 LR/STM4 LH 15 50 F aceplate and Bloc k Diagram Y ou can install the OC12 LR/STM4 LH 1550 card in Sl ots 1 to 4 and 14 to 17 .
4-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.7 4.6.2 OC12 LR/STM4 LH 1550 Port-Level Indicators 4.6.2 OC12 LR/STM4 LH 1550 Port-Level Indicators Y ou can find the status of the OC12 LR/STM 4 LH 1550 card port b y using the LCD screen o n the ONS 15454 fan -tray assembly .
4-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.7 4.7 OC12 IR/STM4 SH 1310-4 Card Figur e 4-6 OC12 IR/STM4 SH 131 0-4 F aceplate and Bloc k Diagr am Y ou can install the OC12 IR/STM4 SH 1310-4 car d in Slots 1 to 4 and 14 to 17.
4-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.8 4.7.1 OC12 IR/STM 4 SH 1310-4 Card -Level Indicators 4.7.1 OC12 IR/STM4 SH 1310-4 Card-Level Indicators T able 4-8 describes the three card-le v el LEDs on the OC12 IR/S TM4 SH 1310-4 card.
4-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.8 4.8.1 OC48 IR 1310 Card-Level Indicators Figur e 4-7 OC48 IR 131 0 Fa ceplat e and Bloc k Diagram Y ou can install t.
4-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.9 4.8.2 OC48 IR 1310 Port-Level Indicators 4.8.2 OC48 IR 1310 Port-Level Indicators Y ou can find the status of the O C48 IR 1310 card port by using the LCD screen on the ONS 1 5454 fan-tray assembly .
4-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.9 4.9.1 OC48 LR 1550 Card-Level Indicators Figure 4-8 OC48 LR 1550 F aceplate and Bloc k Diagram Y ou can install OC48.
4-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.10 4.9.2 OC48 LR 1550 Port-Level Indicators 4.9.2 OC48 LR 1550 Port-Level Indicators Y ou can find the status o f the OC48 LR 1550 card port b y using the LCD screen on the ONS 15454 fan-tray assembly .
4-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.10 4.10.1 OC48 IR/STM1 6 SH AS 1310 Card-Level Indicators Figur e 4-9 OC48 IR/STM16 SH A S 131 0 F acep late an d Bloc.
4-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.11 4.10.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators 4.10.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators Y ou can find the status o f the OC48 IR/STM16 SH AS 1310 card port b y using th e LCD screen on the ONS 15454 fan -tray assembly .
4-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.11 4.11.1 OC48 LR/STM1 6 LH AS 1550 Card-Level Indicators Figure 4-1 0 OC48 LR/STM16 LH AS 1550 Faceplate and Bloc k D.
4-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.12 4.11.2 OC48 LR/STM 16 LH AS 1550 Port-Level Indicators 4.11.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators Y ou can find the status of the OC4 8 LR/STM16 LH A S 1550 card port by using the LCD screen on the ONS 15454 fan -tray assembly .
4-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.12 4.12 OC48 ELR/STM16 EH 100 GHz Cards Figure 4-1 1 OC48 ELR/STM16 EH 1 0 0 GHz Fac eplat e and Bloc k Diagr am Nineteen of the cards operate in t he blue band with spacing of 100 GHz on the ITU grid (1528.
4-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.13 4.12.1 OC48 ELR 100 GHz Card-Level Indicators ONS 15216 100-GHz f ilters, the link b udget is reduced b y the insertion loss of the filt ers plus an additional 2-dB po wer penalty .
4-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.13 4.13 OC48 ELR 20 0 GHz Cards Figur e 4-12 OC48 ELR 20 0 GHz F aceplat e and Block Diagr am Nine of the cards oper ate in the blue band with spacing of 200 GHz on the ITU gri d (1530.
4-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.14 4.13.1 OC48 ELR 200 GHz Card-Level Indicators The OC48 ELR 200 GHz cards support extended long -reach application s in conjunction with opt ical amplif ication.
4-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.14 4.14.1 OC192 SR/ST M64 IO 1310 Card-Level Indicators War ni ng The laser is on when th e optical card is boote d. The port does not have to be in service for the laser to be on.
4-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.15 4.14.2 OC192 SR/STM64 IO 1310 Port-Level Indicators 4.14.2 OC192 SR/STM64 IO 1310 Port-Level Indicators Y ou can find the status of the OC192 SR/STM64 IO 1310 card ports b y using the LCD screen on the ONS 15454 fan -tray assembly .
4-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.15 4.15.1 OC192 IR/STM64 SH 1550 Card-Level Indicators Figure 4-14 OC192 IR/STM64 SH 155 0 F aceplat e and Block Diagr am Note Y ou must use a 3 to 15 dB fiber attenuator (5 dB recommended) when working with the OC192 IR/STM64 SH 1550 card in a loopback.
4-33 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.16 4.15.2 OC192 IR/STM64 SH 1550 Port-Level Indicators 4.15.2 OC192 IR/STM64 SH 1550 Port-Level Indicators Y ou can find the status of the O C192 IR/STM64 SH 1550 card por ts by using the LCD scr een on the ONS 15454 fan -tray assembly .
4-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.16 4.16 OC192 LR/STM64 LH 1550 Card War ni ng The laser is on when th e optical card is boote d.
4-35 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.16 4.16 OC192 LR/STM64 LH 1550 Card Figur e 4-16 Enlarg ed Se ction of the OC192 LR/S TM64 LH 1550 (15454-OC192LR1550) Faceplat e Figure 4-17 shows the OC192 LR/STM6 4 LH 1550 (154 54-OC192-LR2) faceplate and a block diagram of the card.
4-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.16 4.16 OC192 LR/STM64 LH 1550 Card Figure 4-17 OC192 LR/STM64 LH 1550 (15454- OC192-LR2) F a ceplate and Bloc k Diagram Figure 4-18 show s an enlar ged vie w of the faceplate w arning on 15454- OC192LR1550.
4-37 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.16 4.16 OC192 LR/STM64 LH 1550 Card Figur e 4-18 Enlarg ed Section of the OC192 LR/S TM64 LH 1550 (15454-OC192-LR2)F a.
4-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.17 4.16.1 OC192 LR/STM64 LH 1550 Card-Level Indicators The card port features a 1550-nm laser and contains a transmit and re ceiv e c onnector (labeled) on the card faceplate.
4-39 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.17 4.17 OC192 LR/STM64 LH ITU 15xx.xx Card Sixteen distinct OC-192 /STM-64 ITU 100 GHz D W DM cards comprise the ONS 15454 DW DM channel plan. Each OC192 LR/STM64 LH IT U 15xx.
4-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.17 4.17.1 OC192 LR/STM64 LH ITU 15xx.xx Card-Level Indicators Figur e 4-20 OC192 LR/STM64 LH ITU 15xx.xx Bloc k Diagram Note Y ou must use a 20-dB fiber attenuato r (15 to 25 dB) when working with the OC192 LR/STM64 LH 15xx.
4-41 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.18 4.17.2 OC192 LR/STM64 LH ITU 15xx.xx Port -Level Indicators 4.17.2 OC192 LR/STM64 LH ITU 15xx.xx Port-Level Indicators Y ou can find the status of the O C192 LR/STM64 LH ITU 15xx.
4-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.18 4.18.1 Slot Co mpatibility by Cross-Connect Card Figur e 4-21 15454_MRC-12 Card F aceplate and Block Diagr am 4.
4-43 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.18 4.18.2 Ports and Line Rates The maximum bandwidth of t he 15454_MRC-12 card is determin ed by the cross-con nect card, as sho wn in T able 4-19 .
4-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.18 4.18.2 Ports and Line R ates – If Port 10 is used as an OC-3, Po rts 9, 11, and 12 can be used as an OC-3 or OC-12. – Any port can be used as an OC-12 or OC-3, as long as all of the abov e rules are follo wed.
4-45 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.18 4.18.3 15454_MRC-12 Card-Level Indicators 4.18.3 15454_MRC-12 Card-Level Indicators T able 4-21 describes the three card-le v el LEDs on the 15454_MRC-12 card.
4-46 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.19 4.18.4 15454_MRC-12 Port-Level Indicators 4.18.4 15454_MRC-12 Port-Level Indicators Each port has an Rx indicator . The LED flashes green if the port is r eceiving a signal, and it flashes red if the port is not receiving a signal.
4-47 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.19 4.19 OC192SR1/STM64IO Shor t Reach and OC192/ST M64 Any Reach Cards LR-2 XFP module. The XFP SR, IR, and LR interf aces each pro vide one bidirectional OC192/STM64 interface compliant with the recommendations d efine d by ITU-T G.
4-48 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.19 4.19 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Cards Figure 4-22 OC192SR1/STM64IO Short Reac h and OC1.
4-49 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.20 4.19.1 OC192SR1/STM64IO Short Reach and OC192/STM64 Any Reach Card-Level Indicators 4.
4-50 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.20 4.20.2 SFP Description 4.20.2 SFP Description SFPs are integrat ed fiber optic transcei v ers that provid e high-speed serial links from a port or slot to the network.
4-51 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.20 4.20.3 XFP Description Figur e 4-24 Act uator/But to n SFP Figur e 4-25 Bail Clasp SFP SFP dimensions are: • Height 0.03 in. (8.5 mm) • W idth 0.53 in . (13.4 mm) • Depth 2.
4-52 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 4 Optical Cards 4.20 4.20.4 PPM Provisioning Figur e 4-26 Bail Cl asp XFP (Unlatched) Figur e 4-27 Bail Clasp XFP (Latched) XFP dimensions are: • Height 0.33 in. (8.5 mm) • W idth 0.72 in.
CH A P T E R 5-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 5 Ethernet Cards Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
5-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.1 5.1.1 Ethernet Cards Note Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly . The cards are then installed into slots di splaying the same sy m bols.
5-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.2 5.1.2 Card Compatibility 5.1.2 Card Compatibility T able 5-2 lists the CTC softw are compatibility for each Ethernet card . Note "Y es" indicates that this card is fu lly or partially supported by the indicated so ftware release.
5-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.2 5.2 E100T-12 Card autoconfigure to operate at either half or fu ll duplex and determine whether to enable o r disable flo w control. Y ou can also configu re Ethernet ports manually .
5-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.2 5.2.1 Slot Compatibility 5.2.1 Slot Compatibility Y o u can install the E100T -12 card in Slots 1 to 6 and 12 to 1 7. Multiple E-Series Eth ernet cards installed in an ONS 15454 c an act independ ently or as a single Ethernet switch.
5-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.3 5.3 E100T-G Card 5.3 E100T-G Card Note For hardware specifications, see the “ A.7.2 E100T -G Card Specifi cations” secti on on page A-44 . The ONS 15454 uses E100T -G cards for Et hernet (10 Mbps) and F ast Ethernet (100 Mbps).
5-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.3 5.3.1 Slot Compatibility Each E100T -G card supports standards-based, wi re-speed, Layer 2 Ethernet swi tching between i ts Ethernet interfaces. The IEEE 802.1Q tag logically isolates traf fic (t ypically subscribers).
5-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.4 5.3.4 Cr oss-Connect Compatibility 5.3.4 Cross-Connect Compatibility The E100T -G card is compat ible with the XC VT , XC10G and XC-VXC- 10G cards. 5.4 E1000-2 Card Note For hardware specifications, see the “ A.
5-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.4 5.4 E1000-2 Card Figure 5-3 E1 0 00 -2 F aceplate and Bloc k Diagram The E1000-2 Giga bit Ethernet card pro vides hi.
5-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.4 5.4.1 Slot Compatibility 5.4.1 Slot Compatibility Y ou can install the E1000-2 card in Slots 1 to 6 and 12 to 17. The E1000 -2 is compatible with the XCVT card but not the XC10G or and XC-VXC-10G cards.
5-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.5 5.5 E1000-2-G Card 5.5 E1000-2-G Card Note For hardware specifications, see the “ A.7.4 E1000-2-G Card Specif ications” section on page A-45 . The ONS 15454 uses E1000-2-G cards for Gig abit Ethe rnet (1000 Mbps).
5-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.5 5.5 E1000-2-G Card Figur e 5-4 E1 0 00 -2-G F ace plate and Bloc k Diagram The E1000-2-G Gigab it Ethernet card pro.
5-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.5 5.5.1 E1000- 2-G Card-Level Indicators Y ou can create lo gical SONE T ports by provisioning STS c hannels to th e packet switch enti ty within the ONS 15454. Logical por ts can be created with a bandwid th granularity of STS-1.
5-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.6 5.6 G1000-4 Card 5.6 G1000-4 Card The G1000-4 card requires the XC10G card. Th e ONS 15454 uses G10 00-4 cards for Giga bit Ethernet (1000 Mbps). The G1000-4 card provides four ports of IEEE-co mpliant, 1000-Mbps interf aces.
5-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.6 5.6.1 STS-24c Restriction switches (such as 1+1 automatic protectio n switching [APS], path pr otection, or bidirection al line switch ring [BLSR]).
5-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.7 5.6.4 Slot Compatibility 5.6.4 Slot Compatibility The G1000-4 card requires Cisco O NS 15454 Release 3.
5-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.7 5.7.1 STS-24c Restriction Figur e 5-6 G1K-4 F aceplate and Bloc k Diagram The G1K-4 Gigabit Ethernet card pro vides.
5-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.7 5.7.2 G1K-4 Compatibility If STS-24c circuits are not bei ng dropped on the card, the full 48 STSs b andwidth can be used with no restrictions (for example, using either a single STS-48c or 4 STS-12c circuits).
5-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.8 5.8 ML100T-12 Card 5.8 ML100T-12 Card Note For hardware specifications, see the “ A.7.8 ML100T -12 Card Specificatio ns” section on page A-46 . The ML100T -12 card provides 12 ports of IEEE 802 .
5-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.8 5.8.1 ML100T-12 Card-Level Indicators Figur e 5-7 ML1 0 0T -12 F aceplate and Bloc k Diagram The card features tw o virtual packet over SONET (POS) ports with a maximum combined bandwi dth of STS-48.
5-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.9 5.8.2 ML100T-12 Port-Level Indicators 5.8.2 ML100T-12 Port-Level Indicators The ML100T -12 card provides a pair of LEDs for each Fast Ethernet port: an amber LED for acti vity (A CT) and a green LED for LINK.
5-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.9 5.9 ML100X-8 Card Figure 5-8 sho ws the card faceplate and block diagram. Figur e 5-8 ML1 0 0X-8 F aceplate and Bloc k Diagram The card features tw o virtual packet over SONET (POS) ports with a maximum combined bandwi dth of STS-48.
5-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.10 5.9.1 ML100 X-8 Card-Level Indicators 5.9.1 ML100X-8 Card-Level Indicators The ML100X-8 card supports tw o card-le vel LED in dicators. T able 5-17 describes the card-level indicators.
5-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.10 5.10 ML1000-2 Card SFP modules are of fered as separate orderable products for maximum customer fle xibility . For details, see the “5.13 Ethernet Card GBICs and SFPs” section on page 5-31 .
5-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.11 5.10.1 M L1000-2 Card-Level Indicators 5.10.1 ML1000-2 Card-Level Indicators The ML1000-2 card faceplate has t wo card -le vel LED indicators, descri bed in T able 5-19 .
5-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.11 5.11 CE-100T-8 Card The CE-100T8 card also supports the link capacity adjustment scheme (LCAS), which all ows hit less dynamic adjustment of SONET link band width. The CE-100T -8 card’ s LCAS is hardware-based, b ut the CE-100T -8 also supports SW -LCAS.
5-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.11 5.11.1 CE-100T-8 Card-Level Indicators switching, and classification. The Et hernet frames are then passed to th e Ethermap where Ethernet traff ic is terminated and is encapsul ated using HDLC or GFP framing on a per port b asis.
5-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.12 5.11.3 Cross- Connect and Slot Compatibility 5.11.3 Cross-Connect and Slot Compatibility The CE-100T -8 card is compatible in Slot s 1 to 6 or 12 to 17 with the XC10G, XC-VXC-10G, or XCVT cards.
5-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.12 5.12 CE-1000-4 Card The CE-1000-4 card pro vides multiple management options th rough Cisco T ransport Controller (CTC), Cisco T ransport Manager (CTM), T ransaction Langu age 1 (TL1), and Simple Netw ork Management Protocol (SNMP).
5-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.12 5.12.1 CE- 1000-4 Card-Level Indicators Figur e 5-1 1 CE-1 0 00-4 F aceplate and Block Diagram 5.12.1 CE-1000-4 Card-Level Indicators The CE-1000-4 card f aceplate has two card-l e vel LED indicator s, described in T able 5-23 .
5-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.13 5.12.2 CE-1000-4 Port-Level Indicators 5.12.2 CE-1000-4 Port-Level Indicators The CE-1000-4 card provides a pair of LEDs for ea ch Gigabit Ethernet port: an amber LED for acti vity (A CT) and a green LED for link stat us (LINK).
5-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.13 5.13.2 GBIC Description 5.13.2 GBIC Description GBICs are inte grated fib er optic transcei vers that pro vide high-speed serial links from a port or slot to the network.
5-33 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.13 5.13.3 G-1K-4 DWDM and CWDM GBICs • Depth 2.56 in. (6.5 cm) GBIC temperature ranges are: • COM—commercial op.
5-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.13 5.13.3 G-1K-4 D WDM and CWDM GBICs The ONS 15454-supported D WDM GBICs reach up to 100 to 120 km ov er single-mode f iber and support 32 different wav elengths in the red and bl ue bands.
5-35 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.13 5.13.4 SFP Description Figur e 5-14 G-Ser ies with CWDM/D WDM GBICs in Cabl e Networ k 5.13.4 SFP Description SFPs are integrated f iber -optic transcei v ers that provide high-speed serial li nks fro m a port or slot to the network.
5-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 5 Ethernet Cards 5.13 5.13.4 SFP Description Figur e 5-16 Act uator/But to n SFP Figur e 5-1 7 Bail Clasp SFP 63066 63067.
CH A P T E R 6-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 6 Storage Access Networking Cards Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
6-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Acce ss Networking Cards 6.1 6.1 FC_MR-4 Card Overview – Dual rate (1G/2G): MM (550 m) and SM (10 km) – Single rate ( 1G): SX (550 m) and LX (10 km) • SONET/SDH support – Four 1.
6-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Access Networ king Cards 6.1 6.1.1 FC_MR-4 Card-Level Indicators Figur e 6-1 FC_MR-4 F aceplate and Bloc k Diagram 6.1.1 FC_MR-4 Card-Level Indicators T able 6-1 describes the two card-le vel LEDs on the FC_MR-4 card.
6-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Acce ss Networking Cards 6.2 6.1.2 FC_MR-4 Port-Level Indicator s 6.1.2 FC_MR-4 Port-Level Indicators Each FC_MR-4 port has a correspond ing A CT/LNK LE D.
6-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Access Networ king Cards 6.2 6.2.2 Enhanced Card Mode – STS-1-Xv where X is 37 to 48 – STS-3c-Xv where X is 12 to 16 – VC4-Xv where X is 12 to 16 6.2.2 Enhanced Card Mode The features av ailable in enhanced ca rd mode are giv en in this section.
6-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Acce ss Networking Cards 6.2 6.2.3 Link Integrity • Negotiati on mechanism to identify wheth er a far -end FC-o ver -SONET ca.
6-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Access Networ king Cards 6.3 6.2.4 Link Recovery • Data port disabled if SO NET/SDH transport is errored 6.
6-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 6 Storage Acce ss Networking Cards 6.4 6.4 FC_MR-4 Card GBICs The FC_MR-4 payloads can be tran sported o ver the follo wing circuit types: • STS • STSn • STS-V Note V irtual T rib utary (VT) an d VT -V circuits are not supported.
CH A P T E R 7-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 7 Card Protection This chapter e xplains the Cisco ONS 1 5454 card protection conf iguration s. T o provision card protectio n, refer to the Cisco ONS 15454 Pr ocedur e Guide . Chapter topics include: • 7.
7-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.1 7.1.1 1:1 Protection 7.1.1 1:1 Protection In 1:1 protection, a working card is paired wi th a protect card of the same type. If the working card fails, the traf fic from the w orking card switches to the prot ect card.
7-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.1 7.1.2 1:N Protection Figur e 7 -2 Example: ONS 15454 Cards in a 1:N Pr ot ection Configur ation (SMB EIA) T able 7-1 prov ides the supported 1:N conf ig urations b y electrical card, as we ll as the card types that can be used for wo rking and protection cards.
7-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.1 7.1.2 1:N Protection 7.1.2.1 Revertive Switching 1:N protection supports re verti ve switching. Re verti v e switching sends the electr ical interfaces (traff i c) back to the original working card after th e card co mes back onli ne.
7-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.2 7.2 Electrical Ca rd Protection and the Backplane 7.2 Electrical Card Protection and the Backplane Protection schemes for electrical cards depend on th e EIA type used on the ONS 15454 backpl ane.
7-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.2 7.2 Ele ctrical Card Protection an d the Backplane 1:1 LD, W orking A 2, 4 2, 4 2, 4, 6 2, 4, 6 2, 4, 6 2, 4, 6 B .
7-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.2 7.2 Electrical Ca rd Protection and the Backplane Figure 7-3 sho ws unprotected low-density electri cal card schemes by EIA type.
7-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.2 7.2 Ele ctrical Card Protection an d the Backplane Figure 7-4 sho ws unprotected high-density el ectrical card schemes b y EIA type.
7-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.2 7.2 Electrical Ca rd Protection and the Backplane Figure 7-5 sho ws 1:1 low-density card p rotection b y EIA type.
7-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.2 7.2 Ele ctrical Card Protection an d the Backplane Figure 7-6 sho ws 1:N protection for lo w-density electrical cards. Figur e 7 -6 1:N Pr ot ection Schemes for Lo w-Density El ectr ical Car ds with EIA T ypes Note EC-1 cards do not support 1:N pr otection.
7-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.2 7.2.1 Standard BNC Protection Figure 7-7 sho ws 1:1 high-density card p rotection by EIA type. Figur e 7 -7 1:1 Pr ot ection Schem es for High -Density Electr ical Cards with UBIC o r MiniBNC EIA Ty p e s 7.
7-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.2 7.2.3 MiniBNC Prot ection 7.2.3 MiniBNC Protection When used with the MiniBNC EIA, the ONS 15454 su pports unprot.
7-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.3 7.3 OC-N Card Protection 7.3 OC-N Card Protection The ONS 15454 pro vides two optical card p rotection methods, 1+1 protection and optimized 1+1 protection. This section covers the general concept of optical card prot ection.
7-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.4 7.4 Unprotected Cards installed side by sid e in the node. A working card mu st be paired with a protect card of the same typ e and number of ports.
7-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protection 7.5 7.5 External Switching Command s A Force switch has a higher priority than a Manu al switch. Lockouts, which pr ev ent traf f ic from switching to the pro tect port under an y circumstance, can only be appli ed to protect cards (in 1+1 confi gurations).
7-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 7 Card Protecti on 7.5 7.5 Ex ternal Switching Commands.
CH A P T E R 8-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 8 Cisco Transport Controller Operation This chapter describes Cisco T ransport Contro ller (CTC), the softw are interface for the Cisco ONS 15454. F or CTC set up and login in formation, refer to the Cisco ONS 1 5454 Pr ocedure Guide .
8-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.1 8.1.1 CTC Softwar e Installed on the TCC2/TCC2P Card Figur e 8-1 CTC Sof t wa re V ersions, .
8-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.2 8.1.2 CTC Software In stalled on the PC or UNIX Workstation 8.
8-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.3 8.3 PC a nd UNIX Work station Requirements 8.3 PC and UNIX Workstation Requirements T o use CTC for the ONS 15454, your computer must ha ve a web bro wser with the correct Jav a Runtime En vironment (JRE) installed.
8-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.3 8.3 PC a nd UNIX Workstation Requirements T able 8-2 Computer Requirements for CTC Area Requ.
8-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.4 8.4 ONS 15454 Connection 8.4 ONS 15454 Connection Y ou can connect to the ONS 15454 in multiple wa ys.
8-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.5 8.5 CTC Window 8.5 CTC Window The CTC windo w appears after you log into an ONS 15 454 ( Figure 8-3 ). The windo w in cludes a menu bar , a toolbar , and a top and bottom pane.
8-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.5 8.5.1 Node View Figur e 8-3 Node V iew (Def ault Login V iew) 8.5.1 Node View Node vie w , shown i n Figure 8-3 , is t he first vie w that appears after you log into an ONS 15454.
8-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.5 8.5.1 Node View The port color in both card and node vie w indicates the port service state. T able 8-6 lists the port colors and their service states.
8-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.5 8.5.1 Node View Figur e 8-4 T er minal Loopback Indicat or Figur e 8-5 Facility Loopbac k Indicat or 8.
8-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.5 8.5.2 Network View 8.5.2 Network View Network vi ew allo ws you to vie w and manage ONS 15454s that hav e DCC connections t o the node that you logged into and an y login node groups you h av e selected ( Figure 8-6 ).
8-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.5 8.5.2 Network View Figur e 8-6 Networ k in CTC Networ k V iew Note Nodes with DCC connections to the login node do not appear if you check ed the Disable Network Discov ery check box in the Login dialog box.
8-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.5 8.5.2 Network View 8.5.2.2 CTC Node Colors The color of a node i n network vie w , sho wn in Ta b l e 8 - 9 , indica tes the node al arm status.
8-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.5 8.5.3 Card View Note Link consolidation is onl y av ailable on non-deta iled maps. Non-detailed maps display nodes in icon form instead of detailed form, mean ing the nodes appear as rectan gles with ports on the sides.
8-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.5 8.5.3 Card View Figur e 8-7 CTC Card V iew Sho wing a DS1 Card Note CTC provides a card view for all ONS 15454 car ds e xcept the TCC2, TCC2P , XCVT , XC10G, and XC-VXC-10G cards.
8-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.5 8.5.4 Pr int or Export CTC Data Note For TXP , MXP , and D WDM card information, refer to the Cisco ONS 15454 D W DM Refer ence Manua l.
8-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisco Transport Con troller Oper ation 8.6 8.6 TCC2/TCC2P Card Reset Whether you choose to print or e xport data, you can choose f rom the follo wing options: • Entire frame—Prints or e xports the entire CTC windo w including the g raphical vie w of the card, node, or netwo rk.
8-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 8 Cisc o Transport Controller Ope ration 8.8 8.8 Software Revert Note T o av oid a node IP and secure IP endi ng up in the same domain after restorin g a database, ensure that the node IP stored in the database differs in domain fr om that of the node in repeater mode.
CH A P T E R 9-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 9 Security This chapter pro vides informatio n about Cisco ONS 15454 users and security . T o provision secu rity , refer to the Cisco ONS 15454 Pr ocedur e Guide . Chapter topics include: • 9.
9-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.2 9.2.1 User Privileges by CTC Action 9.2.1 User Privileges by CTC Action T able 9-1 shows the actions that each user pri vilege le vel can perform in node vie w .
9-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.2 9.2.1 User Privileges by CTC Action Security Users: Cr eate/Delete/Clear Security Intrusion Alarm — ——X Users: Edit .
9-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.2 9.2.1 User Privileges by CTC Action In v entory — Delete — — X X R e s e t — XXX Maintenance Database Backup — X.
9-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.2 9.2.1 User Privileges by CTC Action T able 9-2 sho ws the actions that each u ser privil ege le ve l can perform in network v iew . 1. The X symbol indicates that th e us er can perform the actions.
9-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.2 9.2.2 Security Policies 9.2.2 Security Policies Users with Superuser security privileges can prov ision securit y policies on the ONS 15454. These security polici es include idle user timeou ts, pa ssword changes, passwor d aging, and user locko ut parameters.
9-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.3 9.3 Audit Trail Note The superuser cannot modify the pri vile ge le vel of an activ e user . The CTC displays a warning message when the superuser attempts to mod ify the pri vileg e le vel of an acti ve user .
9-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.4 9.3.2 Audit Trail Capacities • Status—Status of the user action (Read, I nitial, Successful, T imeout, Failed) • T ime—T ime of ch ange • Message T ype—Whether the ev ent is Success/F ailure type • Message Details—Description of the change 9.
9-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.4 9.4.2 Shared Secrets 9.4.2 Shared Secrets A shared secret is a text string that serves as a password between: • A RADIUS.
9-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 9 Security 9.4 9.4.2 Shared Secrets.
CH A P T E R 10-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 10 Timing This chapter pro vides informatio n about Cisco ONS 15454 SONET timing . T o provision timing, r efer to the Cisco ONS 15454 Pr ocedur e Guide . Chapter topics include: • 10.
10-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 10 Timin g 10.2 10.2 Network Timi ng Caution Mixed ti ming allo ws you to select both e xternal and line ti ming sources. Ho we ver , Cisco does not recommend its use because it can create timing loo ps.
10-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 10 Timing 10.3 10.3 Synchronization Status Messaging Figur e 1 0-1 ONS 15454 Timing Example 10.3 Synchronization Status Messaging Synchronization st atus messaging (SSM) i s a SONET protocol that communicates informat ion about the quality of the timing sou rce.
10-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 10 Timin g 10.3 10.3 Synchronization Status Messaging ST2 3 Stratum 2 ST3 4 Stratum 3 SMC 5 SONET mini mum clock ST4 6 Stratum 4 DUS 7 D.
CH A P T E R 11-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 11 Circuits and Tunnels Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
11-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.1 11.1 Overview • 11.20 Recon figured Circuits, page 11-43 • 11.21 VLAN Management, page 11 -44 • 11.22 Server T rails, page 11-44 11.1 Overview Y ou can create circuits across and within ONS 15454 nodes and assign dif ferent attributes to circuits.
11-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.2 11.2 Circuit Propertie s the Cisco ONS 15 454 D WDM Inst allation and Op eration s Guide) . VCA T circuits are VT1.5- n v, STS-1- n v , STS-3c- n v , and STS-12c- n v , where n is the number of members.
11-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.2 11.2.1 Concatenat ed STS Time Slot Assignments Figur e 1 1 -1 ONS 15454 Circuit Window in Netw or k View 11.
11-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.2 11.2.1 Concatenate d STS Time Slot Assignments 40 Y e s Y e s Y e s N oN oN oN oN oN o 43 Y es Y e s No No.
11-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.2 11.2.2 Circuit Status 11.2.2 Circuit Status The circuit statuses that appear in the Circuit windo w Status column are generated b y CTC based on conditions alon g the circuit path.
11-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.2 11.2.3 Circuit States 11.2.3 Circuit States The circuit service state is an aggregate of the cross-conn ect states within the circuit.
11-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.2 11.2.3 Circuit States • If all cross-connects in a circuit are in an Out-of-Service (OOS) service state, .
11-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.2 11.2.4 Circuit Protection Types T o find the remain ing port soak time, choose the Ma in tenance > AINS Soak tabs in card view and click the Retrie ve b utton.
11-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.2 11.2.5 Circuit Info rmation in the Edit Circuit Window 11.2.5 Circuit Information in the Edit Circuit Window Y o u can edit a selected circuit using the Edit bu tton on the Circuits window .
11-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.2 11.2.5 Circuit Info rmation in the Edit Circuit Window By default, th e working pat h is indicated b y a green, bidirectional arro w , and the protect path is indicated by a purple, bidirectio nal arro w .
11-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.3 11.3 Cross-Connect Card Bandwidth Figur e 1 1 -2 BLSR Circui t Displa yed on the Detailed Cir cuit Map 11.
11-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.3 11.3 Cross-Connect Card Ban dwidth For e xample, if you create a VT1.5 circuit from an STS-1 on a drop card, tw o VT matrix STS ports are used, as shown in Figure 11-3 .
11-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.3 11.3 Cross-Connect Card Bandwidth Figur e 1 1 -4 T wo VT1 .5 Cir cuits in a BLSR Note Circuits with DS1-14 and DS1N-14 circuit sources or destinatio ns use one STS port on the VT matrix.
11-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.4 11.4 Portless Transmux Cross-connect card resour ces ca n be viewed on the Maintenance > Cross-Connect > Re source Usage tab . This tab sho ws: • STS-1 Matrix—The percent of STS matrix resources that are used.
11-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.5 11.5 DCC T unnels T able 11-7 lists the portless tran smux for XCVT trunk ports and for XC10G or XC- VXC-10G any-slo t ports.
11-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.5 11.5.1 Trad itional DCC Tunnels 11.5.1 Traditional DCC Tunnels In traditional DCC tunnels, yo u can use the three LDCCs and the SDCC (when no t used for ONS 15454 DCC terminations).
11-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.6 11.5.2 IP-Encapsulated Tunnels • A SDCC that i s terminat ed cannot be use d as a DCC tunnel endpoint. • A SDCC that is used as an DCC tu nnel endpoint cannot be terminated.
11-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.8 11.8 Monitor Circuits 11.8 Monitor Circuits Monitor circuits are secondar y ci rcuits that monitor traf fic on primary bi directional circuits. Figur e 11-6 sho ws an example of a m onitor circuit.
11-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.9 11.9.1 Open-Ended Path Protection Circuits Figur e 1 1 -7 Editing P ath Pr otec tion Selectors 11.
11-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.10 11.10 BLSR Protection Chan nel Access Circuits Figur e 1 1 -8 P ath Pr otection Go-and-Retur n Routing 11.
11-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.11 11.11 BLSR STS and VT Squelch Tables 11.11 BLSR STS and VT Squelch Tables ONS 15454 nodes display STS and VT squelch tables depending on the type of circuits created.
11-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.12 11.12 Section and Path Trace When using a VT circuit on a VT tunnel (VTT), the V TT allows multiple VT circui ts to be passed through on a sing le STS without consumi ng VT matrix resource s on the cross-conn ect card.
11-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.13 11.13 Path Signal Label, C2 Byte If the string recei ved at a ci rcuit drop port does not mat ch the string the port e x pects to receiv e, an alarm is raised.
11-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.13 11.13 Path Signal Label, C2 Byte (LLC)/Subnetwork Access Protocol (SN AP) header f ields on an Ethernet netw ork; it allo ws a singl e interface to transp ort multiple payload types simultaneou sly .
11-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.14 11.14 Au tomatic Circuit Routing 11.14 Automatic Circuit Routing If you select automatic r outing during circui t creation, CTC routes the circuit b y di viding th e entire circuit route into segments based on p rotection domai ns.
11-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.14 11.14.1 Bandwidth Allocation and Routing • Circuit routing does no t use links that are do wn. If you w ant all links t o be considered for routing, do not create circuits when a link is down.
11-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.15 11.15 Manual Circuit Routing Se veral rules apply to secondary sources and destinations: • CTC does not allo w a secondary de stination for uni directional circuit s because you can alway s specify additional d estinations after you create th e circuit.
11-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.15 11.15 Manual Circuit Routing Figur e 1 1 -1 0 Alter nate P aths for V i rt ual P ath Prot ection Segments • For multi card EtherSwitch circuits, the Ful ly Path Protected option is ignor ed.
11-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.15 11.15 Manual Circuit Routing Figur e 1 1 -12 Ethernet Shar ed P ac k et Ring Routing • Multicard EtherSwitch ci rcuits can ha ve v irtual path prot ection se gments if the source o r destination is not in the pat h protection domai n.
11-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.15 11.15 Manual Circuit Routing Double UPSR 2 — — 2 Double UPSR — 2 2 — Tw o w a y 1 1 — — Ethe.
11-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.16 11.16 Constraint-Bas ed Circuit Routing Although virtual path protectio n segments are possib le in VT tunnels, VT tunnels are still considered unprotected.
11-33 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.17 11.17 Virtual Concatenated Circuits 11.17 Virtual Concatenated Circuits V irtual concatenated (VCA T) ci.
11-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.17 11.17.2 VCAT Member Routing Figur e 1 1 -14 V CA T Common Fiber Routing CE-Series cards also support split f iber routing, which allows t he indiv idual members to be routed on different f ibers or each member to ha ve dif ferent routing constraints.
11-35 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.17 11.17.3 Link Capac ity Adjustment 11.17.3 Link Capacity Adjustment The CE-100T -8 card supports the link capacity adjustment scheme (LCAS), which is a signaling protocol that allows dynamic bandwi dth adjustm ent of VCA T circuits.
11-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.17 11.17.4 VCAT Circuit Size Use the Memb ers tab in the Ed it Circuit w indow to add or delete m embers from a VCA T circuit. The capability to add or delete members depen ds on the card and whether the VCA T circuit is LCAS, SW -LCAS, or non-LCAS.
11-37 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.18 11.18 Bridge and Roll 11.18 Bridge and Roll The CTC Bridge and Roll wizard reroutes liv e traf f ic without interrupti ng service.
11-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.18 11.18.1 Rolls Window Figure 1 1 -16 Rolls Window The Rolls windo w informatio n includes: • Roll From Circuit— The circuit that has connectio ns that will no long er be used when the r oll process is complete.
11-39 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.18 11.18.2 Roll Status • Roll From Circuit—The circuit that has connections that will no longer be used when the process is complete. • Roll From Path — The old path that is being rerouted.
11-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.18 11.18.3 Single and Dual Rolls Note Y ou can only reroute ci rcuits in the DISCO VERED st atus. Y ou cannot reroute circuits that are in the R OLL_PENDING status.
11-41 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.18 11.18.3 Single and Dual Rolls Figure 1 1 -19 Single Roll from One Cir cuit to Another Circuit (Destination Changes) Figure 11-2 0 shows one ci rcuit rolling on to another circuit at the source.
11-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.19 11.18.4 Tw o Circuit Bridge and Roll Figur e 1 1 -22 Dual Roll to Rer oute t o a Dif f er ent Node Note I.
11-43 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tun nels 11.20 11.20 Reconfigured Circuits • Circuits types must be a compatible. F or example, you can combine an STS circuit wi th a V AP circuit to create a longer V AP circuit, but you cannot combin e a VT circuit wit h an STS circuit.
11-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 11 Circuits and Tunnels 11.21 11.21 VLAN Management 11.21 VLAN Management In Software Release 4.6 and later , VLANs are populated within topologies to limit broadcasts to each topology rath er than to the entire networ k.
CH A P T E R 12-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 12 SONET Topologies and Upgrades Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
12-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.2 12.2 Bidirectional Line Switched Rings 12.2 Bidirectional Line Switched Rings The ONS 15454 can s.
12-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.2 12.2.1 Two-Fiber BLSRs Figur e 12-1 Four -Node, T wo-Fiber BLSR The SONET K1, K2, an d K3 bytes carry the informatio n that gov erns BLSR prot ection switches.
12-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.2 12.2.1 Two-Fiber BLSRs Figur e 12-2 Four -Node, T w o-Fiber BLSR T raf fic P atter n Sample Figure 12-3 sh ows ho w traff ic is rer outed follo w ing a line break between No de 0 and Node 3.
12-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.2 12.2.2 Four-Fiber BLSRs Figur e 12-3 Four -Node, T wo-Fiber BLSR T r af fic P at ter n Following Line Br eak 12.2.2 Four-Fiber BLSRs Four -f iber BLSRs double the bandwid th of two-f iber BLSRs.
12-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.2 12.2.2 Four-Fiber BLSRs Figur e 12-4 Four -Node, Four -Fiber BLSR Four -f iber BLSRs pro vide span and ring swit ching: • Span switching ( Figure 12-5 on page 12-7 ) occurs when a working span fails.
12-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.2 12.2.2 Four-Fiber BLSRs Figur e 12-5 Four -Fiber BLSR Span Sw itch • Ring switching ( Figu re 12-6 ) occurs when a span switch cannot recover traf fic, such as when both the wor king and prot ect f ibers f ail on the s ame span.
12-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.2 12.2.3 BLSR Bandwidth Figur e 12-6 Four -Fibe r BLSR Ring S witch 12.2.3 BLSR Bandwidth BLSR nodes can terminate traf fic comi ng from either si de of the ring .
12-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.2 12.2.4 BL SR Applicatio n Example Figure 12-7 sho ws an example of BLSR bandwidth reuse.
12-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.2 12.2.4 BLSR Application Example • The ONS 15454 OC-3 card supports a to tal of four OC-3 ports so that two additio nal OC-3 spans can be added at little cost.
12-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.2 12.2.4 BL SR Applicatio n Example Figure 12-9 Shelf Assembly Lay out for Node 0 in Figure 12-8 Figure 12-1 0 shows the shelf assembly layout for the remain ing sites in the ring.
12-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.2 12.2.5 BL SR Fiber Co nnections 12.2.5 BLSR Fiber Connections Plan your f iber connectio ns and use the same p lan fo r all BLSR nodes.
12-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.3 12.3 Dual-Ring Interconnec t Figure 12-12 Conne cting Fiber to a F our -No de, Four -Fiber BLSR 12.
12-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.3 12.3.1 BLSR D RI • Both a service selector and a path selector • Both a line switch and a pa.
12-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.3 12.3.1 BLSR DRI Figure 12-13 ONS 15454 T raditio nal BLSR Dual-Ring Inter con nect (Same-Si de Routing) Figure 12-1 4 shows ONS 15454 nodes in a traditional BLSR -DRI topolog y with opposi te-side routing.
12-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.3 12.3.1 BLSR D RI Figure 12-14 ONS 15454 T raditio nal BLSR Dual-Ring Inter conne ct (Opposite- Side Routing) Figure 12-1 5 shows ONS 15 454s in an inte grated BLSR-DRI topology .
12-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.3 12.3.1 BLSR DRI Figur e 12-15 ONS 15454 Int egrat ed BLSR Dual-Ring Int erconnect Figure 12-1 6 shows an e xample of an integrat ed BLSR DRI on the Edit Circuits wind ow .
12-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.4 12.4 Comparison of the Prote ction Schemes Figur e 12-16 Int egrat ed BLSR DR I on the Edit Circ uits Windo w 12.4 Comparison of the Protection Schemes T able 12-4 sho ws a comparison of the different protection schemes using OC-48 as an example.
12-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.5 12.5 Linear ADM Configurations 12.5 Linear ADM Configurations Y ou can configure ONS 1545 4s as a line of add/drop multiple xe rs (ADMs) by conf iguring one set of OC-N cards as the working path and a seco nd set as the protect path.
12-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.6 12.6 Path -Protected M esh Networks Figur e 12-18 P ath-Prot e cted Mesh Networ k PPMN also allo ws spans with dif ferent SONET speeds to be mixed together in “vi rtual rings.
12-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.7 12.7 Four-Shelf Node Configura tions Figur e 12-19 PPMN Vir tual Ring 12.
12-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.8 12.8 OC-N Speed Upgrad es Figur e 12-20 Four -Shelf Node Configuration 12.8 OC-N Speed Upgrades A span is the optical f iber connection b etween two ONS 15454 nodes.
12-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.8 12.8 OC-N Speed Upg rades • OC-48 to OC192SR1/STM64IO Sh ort Reach or OC192/STM64 An y Reach T able 12-5 lists permit ted upgrades for Slots 5, 6, 12, and 13 (high-speed slo ts).
12-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.8 12.8.1 Span Upgrade Wizard Note Replacing cards that are the same speed are not co nsidered span upgrades. For e xample replacing a four-port OC-3 wit h an eight-port OC-3 card or replacing a single-p ort OC-12 with a four-port OC-1 2 card.
12-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.9 12.9 In-Service Topolo gy Upgrades Procedures for manual span upgrad es can be found in the “Upgrade Card s and Spans” chapt er in the Cisco ONS 15454 Pr ocedur e Guide .
12-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.9 12.9.1 Unprotected Point-to -Point or Linea r ADM to Path Protection 12.
12-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Topologi es and Upgrades 12.9 12.9.3 Path Protection to Two-Fiber B LSR 12.9.3 Path Protection to Two-Fiber BLSR CTC provides a to pology con version wizard to co n vert a path protection to a tw o-f iber BLSR.
12-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 12 SONET Top ologies and Upgrades 12.9 12.9.5 Add or Remov e a Node from a Topo logy.
CH A P T E R 13-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 13 Management Network Connectivity This chapter pr ovides an o vervi ew of ONS 15454 data communicat ions network (DCN ) connecti vity .
13-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2 IP Addressing Scenarios • IP subnetting can cr eate multiple logical ONS 1 5454 networks within a single Class A, B, or C IP network. If you do not subnet, you will only be able to use one netw ork from your Class A, B, or C network.
13-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.1 IP Scena rio 1: CTC and ONS 15454s on Same Subnet 13.2.1 IP Scenario 1: CTC and ONS 15454s on Same Subnet IP Scenario 1 sho ws a basic ONS 15454 LAN co nfigu ration ( Figure 13-1 ).
13-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.3 IP Scenario 3: Usin g Proxy ARP to Enable an ONS 15454 Gateway Figur e 13-2 IP Scenar io 2 : CTC and ONS 15454 Nodes Connect ed to a Rout er 13.
13-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.3 IP Scenario 3: Using Pro xy ARP to Enable an ONS 15454 Gateway IP Scenario 3 is similar to IP Scenario 1, b u t only one ONS 15454 (1) co nnects to the LAN ( Figure 13-3 ).
13-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.4 IP Scenario 4: Default Gateway on a CTC Computer In Figure 13-4 , Node 1 announces to Node 2 an d 3 that it can reach the CTC host. Similarly , Node 3 announces that it can reach the ONS 1 52xx.
13-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs Figure 13-5 IP Scenar io 4: Default Gat ewa y on a CTC Computer 13.
13-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.5 IP Scenario 5: Us ing Static Routes to Connect to LANs Figur e 13-6 IP Scenar io 5: Stat.
13-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.5 IP Scenario 5: Using Static Routes to Connect to LANs Figur e 13-7 IP Scenario 5: Static Ro ute With Mu ltiple LAN Destinations CTC Workstation IP Address 192.
13-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.6 IP Scenario 6: Using OSPF 13.2.6 IP Scenario 6: Using OSPF Open Shortest Path F irst (OSPF) is a link state Intern et routing protocol.
13-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.6 IP Scenario 6: Using OSPF Figur e 13-8 IP Scenario 6: OSPF Enabled CTC Workstation IP Address 192.168.1.100 Subnet Mask 255.255.255.0 Default Gateway = 192.
13-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.7 IP Scenario 7: Pr ovisioning the ONS 15454 SOCKS Proxy Server Figur e 13-9 IP Scenar io 6: OSPF Not Enabled 13.
13-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server The ONS 15454 gate way setting performs the follo wing task s: • Isolates DCC IP traff ic from Ethernet (craft port) traff ic and accepts packets based on filtering rules.
13-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.7 IP Scenario 7: Pr ovisioning the ONS 15454 SOCKS Proxy Server Note If you launch CTC ag.
13-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server Figur e 13-1 1 IP Scenario.
13-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.7 IP Scenario 7: Pr ovisioning the ONS 15454 SOCKS Proxy Server Figur e 13-12 IP Scenar io 7: ONS 15454 SOCKS Pr o xy Server with GNE and ENEs on Diff erent Subnets 71674 Remote CTC 10.
13-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.7 IP Scenario 7: Provisioning the ONS 15454 SOCKS Proxy Server Figur e 13-13 IP Scenario .
13-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.8 IP Scenario 8: Dual GNEs on a Subnet If you implement the SOCKS pr oxy server , note th at all DCC-conn ected ONS 15454s on the same Ethernet segment must hav e the same gate way set ting.
13-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.8 IP Scen ario 8: Dual GNEs on a Subne t Figur e 13-14 IP Scenar io 8: Du al GNEs on the Same Subnet Figure 13-1 5 shows a netw ork with dual GNEs o n dif ferent subnets.
13-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.2 13.2.9 IP Scenario 9: IP A ddressing with Secure Mode Enabled Figur e 13-15 IP Scenar io 8: Du al GNEs on Diff er ent Subnets 13.
13-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.2 13.2.9 IP Scenario 9: IP Addressing with Secure Mode Enabled Figure 13-16 on page 13-21 sho ws an examp le of ONS 15454s on the same subn et with secure mode enabled.
13-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.3 13.3 Provisionable Patchcords Figur e 13-17 IP Scenar io 9: ONS 15454 GNE and EN Es on Dif f er ent Subnets with Secur e Mode Enabled 13.
13-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.3 13.3 Provisionable Patchcords T able 13-5 lists the support ed card combinations for client and trun k ports in a pr ovisionab le patchcord.
13-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.4 13.4 Routing Table Optical ports ha ve the fo llo wing requirements when used in a provision a.
13-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.5 13.5 External Firewalls Entry 1 sho ws the follo wing: • Destination (0.0.0.0) is th e default route ent ry . All un defined destination n etwork or host entr ies on this routing table are mapped to the def ault route entry .
13-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.5 13.5 Ex ternal Firewa lls The follo wing A CL example sho ws a f irew all configuration when the SOCKS proxy server gate way setting is not enabled.
13-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.6 13.6 Open GNE access-list 100 remark *** allows CTC communication with ONS 15454 GNE (port 57790) *** access-list 100 remark access-list 100 permit tcp host 192.
13-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.6 13.6 Ope n GNE T o set up proxy and f ire wall subnets in CTC, use the Pr ovisioni ng > Network > Proxy and Fire walls subtabs.
13-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7 T CP/IP and OSI Networking Figure 13-1 9 Foreign Node Connection to an ENE Ethernet P ort 13.7 TCP/IP and OSI Networking ONS 15454 DCN commu nication is based on the TCP/IP protocol suite.
13-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.1 Point-to-Point Protoc ol 13.7.1 Point-to-Point Protocol PPP is a data link (Layer 2) encapsula tion protocol that transports data grams o ver point-to-point links.
13-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.2 Link Access Protocol on the D Channel 13.7.2 Link Access Protocol on the D Channel LAP-D is a data link pro tocol used in the OSI prot ocol stack.
13-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.3 OSI C onnecti onless Network Service CLNP uses network service access point s (NSAPs) to identify network de vices. The CLNP source and destination addresses are NSAPs.
13-33 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.3 OSI Connectionless N etwork Service Figure 13-2 0 shows the ISO-DCC NSAP address wi th the default v alues deli vered with the ONS 15454. The System ID is automatically p opulated with the node MA C address.
13-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.4 OSI Routing Figur e 13-21 OSI Main Setup This address is also the Rout er 1 primary manual ar ea address, which is vie wed and edited o n the Provisio ning > OSI > Routers subtab .
13-35 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.4 OSI Routing In OSI network ing, discov ery is based on announcements. An ES uses the ES-IS protocol end system hello (ESH) message to announc e its presence to IS s and ESs connected to the same netw ork.
13-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.4 OSI Routing • Intermediate System Le vel 1/Le vel 2—The ONS 15454 performs IS function s. It communicates with IS and ES nodes t hat reside within its OSI ar ea.
13-37 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.5 TARP 13.7.5 TARP T ARP is used when TL1 target id entif iers (TIDs) must be translated to NSAP addresses.
13-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.5 TARP 13.7.5.1 TARP Processing A T ARP data cache (TDC) is created a t each NE to facilitate T ARP processing. In CTC, the TDC is displayed an d managed on t he node view Maintenance > OSI > TDC subt ab .
13-39 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.5 TARP 13.7.5.2 TARP Loop Detection Buffer The T ARP loop detection b uf fer (LDB) can be enable d to pre vent dup licate T ARP PDUs from entering the TDC.
13-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.6 TCP/IP and OSI Mediation Figur e 13-23 Manual T ARP Adjacencies 13.7.5.4 Manual TID to NSAP Provisioning TIDs can be manually linked to NSAPs and added to the TDC.
13-41 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.7 OSI Virtual Routers Figure 13-24 T–TD Protocol Flow • FT–TD—Performs an FTP con version between FT AM and FTP .
13-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.7 OSI Virtual Routers Figure 13-26 Provisioning OSI Routers Each router has an editable manu al area addr ess and a unique NSAP System ID that is set to the n ode MA C address + n .
13-43 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.8 IP-over-CLNS Tunnels Each OSI virtual rout er has a primary manual area address. Y ou can also create two additional manual area addresses.
13-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.8 IP-over-CLNS Tunnels Figur e 13-27 IP -o ver -CLNS T u nnel Flow 13.7.8.1 Provisioning IP-over-CLNS Tunnels IP-ov er -CLNS tunnels must be carefully planned to pre vent nodes from losing visibility or connecti vity .
13-45 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.8 IP-over-CLNS Tunnels If you are pro visioning an IP-ov er -CLNS tunnel on a Cisco router , always fo llow p rocedures pro vided in the Cisco IOS documentati on for the router you are pro visioning.
13-46 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.8 IP-over-CLNS Tunnels Figur e 13-28 IP -o ver -CLNS T unnel Scenar io 1: ONS NE to Other V e nder GNE 13.7.8.3 IP-over-CLNS Tunnel Scenario 2: ONS Node to Router Figure 13-2 9 shows an IP-o ver -CLNS tunnel from an ONS node to a router .
13-47 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.8 IP-over-CLNS Tunnels clns routing interface ctunnel 102 ip address 10.10.30.3 0 255.255.255.0 ctunnel destination 39.8 40F .80.1111.0000.1111.
13-48 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.8 IP-over-CLNS Tunnels ONS NE 1 IP-ov er -CLNS tunnel pro visioning: • Destination: Router 2 IP address • Mask: 255.255.255. 255 for host route (CTC 1 o nly), or 255.
13-49 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.9 O SI/IP Networking Scenario s Figur e 13-30 IP -ov er -CLNS T unn el Scenar io 3: ONS Node to Rout er Acr oss an OSI DCN 13.
13-50 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.9 OSI/IP Networking Scenarios • All ONS 15454 NEs participating in an OSI netw ork run OSI o ver PPP between t hemselves.
13-51 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.9 O SI/IP Networking Scenario s Figur e 13-32 OSI/IP Scenar io 2: IP O SS, IP DCN, ONS GNE, OSI DCC, and Other V endor ENE The ONS 15454 GNE routes TL1 traff ic to the correct NE by resolving the TL1 TID to either an IP or NSAP address.
13-52 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.9 OSI/IP Networking Scenarios OSS-initiated soft ware do wnloads cons ist of two part s: the OSS to destinat ion NE TL1 do wnload request and the f ile transfer .
13-53 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.9 O SI/IP Networking Scenario s Figur e 13-33 OSI/IP Scenar io 3: IP OSS , IP DCN, Other .
13-54 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.9 OSI/IP Networking Scenarios Figur e 13-34 OSI/IP Scenar io 3 with OSI/IP -ov er -CLNS T unnel Endpoint at the GNE 13.
13-55 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.9 O SI/IP Networking Scenario s Figur e 13-35 OSI/IP Scenar io 4: Multiple ONS DCC Ar eas 13.
13-56 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.9 OSI/IP Networking Scenarios Figur e 13-36 OSI/IP Scenar io 5: GNE Witho ut an OSI DCC Connection 13.
13-57 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.9 O SI/IP Networking Scenario s Figure 13-37 OSI/IP Scenar io 6: IP OSS, OSI DCN, ONS GNE, OSI DCC, and Other V endor ENE 13.
13-58 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.9 OSI/IP Networking Scenarios Figur e 13-38 OSI/IP Scenar io 7: OSI OSS , OSI DCN, O ther V ender GNE, OSI DCC, and ONS NEs In European netwo rks: • CTC and CTM are used for managem ent only .
13-59 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.9 O SI/IP Networking Scenario s • TL1 management is not required. • FTP file tr ansfer is not required. • TL1 and FT AM to FTP mediation is not required.
13-60 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.9 OSI/IP Networking Scenarios Figur e 13-39 OSI/IP Scenar io 8: OSI OSS , OSI DCN, ONS GNE, OSI DCC, and Other V ender NEs 1 The ONS NEs are ma naged by CTC/CTM only (TL1 /FTP is not used).
13-61 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Management N etwork Connectivity 13.7 13.7.10 Provisioning OSI in CTC 13.7.10 Provisioning OSI in CTC T able 13-18 sho ws the OSI actions that are performed from th e node view Pro visioning tab .
13-62 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 13 Ma nagement Network Connectivity 13.7 13.7.10 Provisioning OSI in CTC.
CH A P T E R 14-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 14 Alarm Monitoring and Management This chapter describe s Cisco T ransport Control ler (CTC) alarm managem ent. T o troubleshoot specific alarms, refer to the Cisco ONS 15454 T r oubleshooting Guide .
14-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.3 14.3 Alarm Information The ONS 15454 has a one- butto n update for some commonly vie wed alarm coun ts.
14-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.3 14.3 Alarm Information Note When an entity is put in the OOS,MT admini strati ve state, the ONS 15454 suppresses all standing alarms on that entity .
14-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.3 14.3.1 Viewing Alarms W ith Each Node’s Time Zo ne 14.3.1 Viewing Alarms With Each Node’s Time Zone By default, alarms and condi tions are displayed w ith the ti me stamp of the CTC workst ation where you are vie wing them.
14-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.3 14.3.4 Viewin g Alarm-Affected Circuits 14.3.4 Viewing Alarm-Affected Circuits A user can vie w which ONS 15454 circuits are af fected by a sp ecific alarm b y positioning th e cursor ov er the alarm in the Alarm wind ow and ri ght-clicking.
14-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.3 14.3.6 Controlling the Conditions Display 14.3.6 Controlling the Conditions Display Y ou can control the display of the conditions on the Cond itions windo w .
14-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.3 14.3.7 Viewing History 14.3.6.3 Filtering Conditions The condition display can be f iltered to prev ent display of condi tions (including alarms) with certain se verities or that occurred between certain dates.
14-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.3 14.3.7 Viewing History If you check the History win do w Alarms check box, you display th e node history of alarms. If you check the Even ts check box, you display th e node hist ory of Not Alarmed and tr ansient e vents (conditions).
14-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.4 14.3.8 Alarm Hi story and Log Buffer Cap acities on the card in the History > Card windo w , or a histor y of alarms, conditions, a nd transients that ha ve occurred during yo ur login session in t he History > Session wind ow .
14-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.5 14.5.1 Creatin g and Modifying Alarm Profiles CTC can store up to ten acti ve alarm profil es at any time to apply to the node. Custom p rofil es can take eight of these acti v e profi le positions.
14-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.5 14.5.2 Alarm Profile Buttons Note Up to 10 prof iles, including th e two reserv ed prof il es (Inherited and Default) can b e stored in CTC.
14-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.5 14.5.3 Alarm Profil e Editing 14.5.3 Alarm Profile Editing T able 14-8 lists and describ es the fi ve prof ile-editing options a vail able when you right-cl ick an alarm item in the profile column.
14-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.6 14.5.6 Applying Alarm Profiles 14.5.6 Applying Alarm Profiles In CTC node vie w , the Alarm Beha vior windo w displays alarm prof iles for the node.
14-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.7 14.6.2 Alarms Suppres sed by User Comman d While the facility is in the OO S,MT state, any ala.
14-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring an d Management 14.7 14.7.2 External Controls • Raised When—Open means that the normal co ndition is to not ha .
14-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 14 Alarm Monitoring a nd Management 14.7 14.7.2 External Controls.
CH A P T E R 15-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 15 Performance Monitoring Performance monitoring (PM) parameters ar e used by ser vice providers to ga ther , store, set thr esholds for , and report performance data fo r early detection of problems.
15-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.1 15.1 Threshold Performance Monitoring During the accumulation cycle, if the current v a lue of a PM parameter reaches or exceeds its correspondi ng threshol d value, a threshold cross ing alert (TCA) is generated by the node and disp layed by C TC .
15-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.2 15.2 Intermedia te Path Performance Monitoring Note Due to limitations of memory and the number of TCAs generated by dif ferent platforms, you can manually add/m odify the follo wing tw o properties to the platform proper ty fil e (CTC.
15-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.3 15.3 Pointer Justific ation Count Perfor mance Monitoring Note Far -end IPPM is not support ed by all OC-N cards. It is supported by O C3-4 and EC-1 cards. Ho we ver , SONET path PMs can be monitored b y logging into the f ar-end no de directly .
15-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.4 15.4 Performance Monitoring Para meter Definitions T able 15-3 P erfor mance Monitor ing P arameters Par.
15-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.4 15.4 Performance Monitoring Pa rameter Definitions CV -S Section Coding V iolation (CV -S) is a count of bit interlea ved parity (BIP) errors detected at the section layer (that is, usin g the B1 byte in the incoming SONET signal) .
15-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.4 15.4 Performance Monitoring Para meter Definitions ES-S Section Errored Seconds (ES-S) is a count of the nu mber of seconds when at least one section-laye r BIP error was detected or an SEF or loss of signal (LOS) defect w as present.
15-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.4 15.4 Performance Monitoring Pa rameter Definitions LOSS-L Line Loss of Signal (LOSS-L) is a count of one-second interv als containing o ne or more LOS defects.
15-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.4 15.4 Performance Monitoring Para meter Definitions PJCS-PDET -P Pointer Justif ication Count Se conds, STS Path Detect (NPJCS-PDET -P) is a count of the one-second interv als contai ning one or more PPJC-PDET or NPJC-PDET .
15-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.4 15.4 Performance Monitoring Pa rameter Definitions PSD-S In a four -fiber BLSR, Protection Switching Duration-Span (PSD-S) i s a count of the seconds that the protecti on line was used to carry service.
15-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.4 15.4 Performance Monitoring Para meter Definitions SESR-PM Path Monitoring Sev erely Errored Seconds Ratio (SESR-PM) indicat es the se verely errored seconds ratio reco rded in the O TN path during the PM time interv al.
15-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5 Performance Monitor ing for Electrica l Cards 15.5 Performance Monitoring for Electrical Cards The .
15-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.1 EC1-12 Card Performan ce Monitoring Parameters Note The XX in Figure 15-2 represents all PMs listed in T able 15-4 with the giv en pref ix and/or suf f ix.
15-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.2 DS1_E1_56 Card Performanc e Monitoring Parameters Note If the CV -L(NE and FE) falls in the range 51-61 for EC1,th en, the user might see discrep ancy in the SES and the U AS-L v alues.
15-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.2 DS1_E1_56 Card Performance Monitoring Parame ters Figur e 15-5 PM Read P oints on the DS1/E1 -56 Card Tx/Rx LIU Ultramapper ASIC Stingra y ASIC DS-1 P ath Side E-1 P ath Side This group of PMs are receiv ed from the f ar end.
15-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.3 DS1-14 and DS1N-14 Card Perfor mance Moni toring Parame ters T able 15-5 lists the PM parameters for the DS1/E1- 56 card.
15-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.3 DS1-14 and DS1N-14 Card Performance Monitoring Parame ters Figur e 15-7 PM Read P oints on the DS1 -14 and DS1N-14 Cards T able 15-6 describes the PM parameters fo r the DS1-14 and DS1N-1 4 cards.
15-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.4 DS3-12 and DS3N-12 Card Perfor mance Moni toring Parame ters 15.
15-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.5 DS3-12E and DS3N-12E Card Performance Monitoring Parame ters Figur e 15-9 PM Read P oints on the DS3-12 and DS3N-12 Car ds The PM parameters for the DS3-12 and DS3N-12 cards are describ ed in Ta b l e 1 5 - 7 .
15-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.5 DS3-12E and DS3N-12E Card Performanc e Monitoring Para meters Figure 15-1 0 Monitored Signal T y pes for the DS3-12E and DS3N-12E Car ds Note The XX in Figure 15-10 represents all PMs listed in T able 15-8 with the g iv en pref ix and/or suf f ix.
15-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.6 DS3i-N-12 Card Performance Monitoring Parame ters 15.5.6 DS3i-N-12 Card Performance Monitoring Parameters Figure 15-1 2 shows the signal types that sup port near -end and far -end PMs.
15-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.6 DS3i-N-1 2 Card Performa nce Monitoring Parameters Figur e 15-13 PM Read P oints on the DS3i-N-12 Cards T able 15-9 describes the PM paramete rs for the DS3i-N-12 card.
15-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.7 DS3XM-6 Card Performance Monitoring Parameters 15.5.7 DS3XM-6 Card Performance Monitoring Parameters Figure 15-1 4 shows the signal types that sup port near -end and far -end PMs.
15-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.7 DS3XM-6 Card Performance Mo nitoring Parameters Figur e 15-15 PM Read P oints on the DS3XM-6 Card T able 15-10 lists the PM parameters for the DS3XM-6 card s.
15-25 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.8 DS3XM-12 Card Performance Monitoring Paramete rs 15.5.8 DS3XM-12 Card Performance Monitoring Parameters Figure 15-1 6 shows the signal types that sup port near -end and far -end PMs.
15-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.8 DS3XM-12 Ca rd Performance Monitor ing Parameters Figur e 15-17 PM Read P oints on the DS3XM-12 Card T able 15-11 lists the PM parameters for the DS3XM-12 cards.
15-27 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.5 15.5.9 DS3-EC1-48 Card Performance Monitoring Parameters 15.5.9 DS3-EC1-48 Card Performance Monitoring Parameters Figure 15-1 8 shows the signal types that su pport near -end and far -end PMs.
15-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.5 15.5.9 DS3-EC1-4 8 Ca rd Perfor mance Monitoring Parameters Figur e 15-19 PM Read Points on the DS3/EC1 -48 Card T able 15-12 lists the PM parameters for the D S3/EC1-48 cards.
15-29 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6 Performanc e Monitoring for Ethernet Card s Note If the CV -L(NE and FE) falls in the range 51-61 for DS3,th en, the user might see discrep ancy in the SES and the U AS-L v alues.
15-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.6 15.6.1 E-Series Ethe rnet Card Performanc e Monitoring Paramete rs etherStatsUndersizePkts The total number of pack ets recei ve d that were less than 64 octets long (excludi ng framing bits, b ut includin g FCS octets) and were otherwise well formed.
15-31 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6.1 E-Series Ethe rnet Card Performance Monitoring Paramete rs 15.
15-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.6 15.6.2 G-Series Ethern et Card Performanc e Monitoring Parame ters 15.
15-33 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6.2 G-Series Ethernet Card Performan ce Monitoring Parameters Note Do not use the HDLC errors counte.
15-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.6 15.6.3 M L-Series E thernet Card Performanc e Monitoring Parameters 15.6.2.3 G-Series Ethernet History Window The Ethernet History windo w lists pa st Ethernet statistics for the pre v ious time interval s.
15-35 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6.3 ML-Series Ethernet Card Performance Monitoring Parameters 15.6.3.2 ML-Series POS Ports Window In the ML-Series POS Ports window , the parameters dis played depend on the framing mo de employed by the ML-Series card.
15-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.6 15.6.3 M L-Series E thernet Card Performanc e Monitoring Parameters mediaIndStatsRxShort Pkts Number of receiv ed packets that are too small.
15-37 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters 15.
15-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.6 15.6.4 CE-Series Etherne t Card Performanc e Monitoring Paramete rs ifOutMulticastPkts 2 Nu mber of multicast pack ets transmitted. ifOutBroadca stPkts 2 Number of broadcast pack ets transmitt ed.
15-39 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters etherStatsOversizePkts The total number of packet s recei v ed that were longer than 1518 octets (excludi ng framing bits, b u t including FC S octets) and were otherwise well formed.
15-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.6 15.6.4 CE-Series Etherne t Card Performanc e Monitoring Paramete rs 15.
15-41 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.6 15.6.4 CE-Series Ethernet Card Performance Monitoring Parameters 15.
15-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.7 15.7 Performance Monitori ng for Optical Cards 15.7 Performance Monitoring for Optical Cards This section lists PM parameters for ONS 15454 opti cal cards, including the OC-3, OC-12, OC-48, and OC-192 cards.
15-43 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.7 15.7 Performa nce Monitoring for Optical Cards T able 15-22 and Ta b l e 1 5 - 2 3 list the PM parameters for OC-3 cards. T able 15-24 lists the PM parameters for OC -12, OC-48, and OC-192 cards.
15-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.8 15.8 Performance Mon itoring for Optical Multirate Cards Note If the C V -L(NE and FE) falls in a s pecific range, th en, the user mig ht see discre pancy in the SES and the U AS-L v alues.
15-45 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.9 15.9 Performance Monitoring for Storag e Access Networking Cards Figure 15-22 PM Read P oints for the MRC-12 Card T able 15-26 lists the PM paramete rs for MRC-12 card.
15-46 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.9 15.9.1 FC_MR-4 Statistics Window CTC provid es FC_MR-4 performance information, in cluding line-le vel paramet ers, port bandwidth consumption, an d historical statisti cs.
15-47 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Mo nitoring 15.9 15.9.2 FC_MR-4 Utilization Window 15.9.2 FC_MR-4 Utilization Window The Utilization wi ndow sh ow s the percentage of Tx and Rx line ban dwidth used by the ports during consecuti ve time se gments.
15-48 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 15 Performance Monitoring 15.9 15.9.3 FC_MR-4 Histor y Window Note Line utilization numbers e xpress th e av erage of ingress and egress traf fic as a percentage of capacity .
CH A P T E R 16-1 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 16 SNMP This chapter e xplains Simple Netw ork Management Protocol (SNMP) as im plemented by the Cisco ONS 15454. For SNMP setup in form ation, refer to the Cisco ONS 15454 Pr ocedur e Guide .
16-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.2 16.2 Basic SNMP Components Note It is recommended that t he SNMP Manager timeout v alu e be set to 60 seconds. Under certain condi tions, if this v alue is lo wer than the recommended time, th e TCC card can reset.
16-3 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.2 16.2 Basic SNMP Components Figur e 16-2 Example of the Pr imary SNMP Components An agent (such as SNMP) residing on each ma.
16-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.3 16.3 SNMP External Interface Re quirement 16.3 SNMP External Interface Requirement Since all SNMP requests come from a thir.
16-5 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.6 16.6 SNMP M anagemen t Informatio n Bases 16.6 SNMP Management Information Bases Section 16.6.1 lists IETF -standard MIBs that ar e implemented in the ONS 15 454 and sho ws their compilation order .
16-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.6 16.6.2 Proprietary ONS 15454 MIBs 16.6.2 Proprietary ONS 15454 MIBs Each ONS 15454 is shippe d with a software CD containi ng applicable proprietary MIBs. Ta b l e 1 6 - 3 lists the proprietary MIBs for the ONS 15454.
16-7 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.6 16.6.3 Generic Thresh old and Perf ormance Mo nitoring MI Bs 16.6.3 Generic Threshold and Performance Monitoring MIBs In Release 7.
16-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7 SNMP Trap Content The cerentGen ericPmStatsCurre ntT able v alidates the current PM v alue usi ng the cerentGen ericPm.
16-9 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.1 Generic and IETF Traps • Object IDs that uniquely identify each e v ent with information about the generating enti.
16-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.2 Variable Trap B indings 16.7.2 Variable Trap Bindings Each SNMP tr ap contains va riable bindin gs that ar e used to create the MIB tables. ONS 15454 traps and v ariable bindings are li sted in Ta b l e 1 6 - 8 .
16-11 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.2 Variable Trap Binding s B (cont.) (4) cerent454AlarmState The alarm sev erity and service-affecting status. Se veritie s are Minor , Major , and Critical. Service-affecting statuses are Service-Affecting and Non-Service Af fecting.
16-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.2 Variable Trap B indings D1 (cont.) (5) alarmRisingThr eshold When the current samp led val ue is greater than or equal to this threshold, and the v alue at the last sampling interv al was less than this threshold, a single e vent i s generated.
16-13 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.2 Variable Trap Binding s D2 (cont.) (7) cerent454AlarmState The alarm sev erity and service-affecting status. Se veritie s are Minor , Major , and Critical. Service-affecting statuses are Service-Affecting and Non-Service Af fecting.
16-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.2 Variable Trap B indings E (cont.) (9) cerent4 54AlarmAdditionalInfo Add itional information for th e alarm object. In the current version o f the MIB, this object contains p rovisioned d escriptio n for alar ms that are extern al to the NE.
16-15 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.7 16.7.2 Variable Trap Binding s F (cont.) (10) ceren t454ThresholdLocation Indicates wh ether the e vent occurred at the near or f ar end. (11) ceren t454ThresholdPeriod Indicates the sampling interv al period.
16-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.8 16.8 SNMP Community Names 16.8 SNMP Community Names Community names are used to group SNMP trap dest inations. All ONS 1545 4 trap destinations can be provisioned as part of SNMP communities in Cisc o T ransport Controller (CT C).
16-17 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.1 64-Bit RMON Monito ring over D CC Certain statistics measured on the ML card are mapped to standard MIB if one e xists else mapped to a non standard MIB v ariable.
16-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.2 HC-RMON-MIB Support 16.10.1.2 Row Creation in cMediaIn dependentHistoryControlTable SNMP row creation and deletion for the cMediaInde pend entHistoryCont rolT able follows th e same processes as for the MediaIndependen tT able; only the v ariables dif fer .
16-19 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.4 History Control RMON Group 16.10.3.2 Get Requests and GetNext Requests Get reques ts and getNext reques ts for th.
16-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.5 Ethernet History RMON Group T o create a SetRequest PDU for the historyControl T able, the following valu es are .
16-21 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.6 Alarm RMON Group 16.10.6.1 Alarm Table The NMS uses the alarmT able to determine and pro vision network perfo rmance alarmable thresholds.
16-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.6 Alarm RMON Group 16.10.6.3 Get Requests and GetNext Requests These PDUs are not restricted. 16.10.6.4 Row Deletion in alarmTable T o delete a row from the table, t he SetRequest PDU sh ould contain an alarmStatu s value of 4 (in valid).
16-23 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.7 Event RMON Group 16.10.7 Event RMON Group The Event grou p controls e vent generati on and notif ica tion.
16-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Chapter 16 SNMP 16.10 16.10.7 Event RMON Group.
A-1 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 APPENDIX A Hardware Specifications Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
A-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.1 A.1.3 Cisco Transport Controller • Regenerator mode • Hubbed rings • Multihubbed rin gs • Point-to-point • Linear • Linear with optical add/dr op multiple xing (O ADM) A.
A-3 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.1 A.1.8 EIA Interface • Backplane access: Alarm pin fields A.
A-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.2 A.1.13 Dimensions • Operating humidity: 5 to 95 percent, non condensing A.1.13 Dimensions The ONS 15454 shelf assembly has the foll owing dimen sions: • Height: 18.
A-5 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.2 A.2 SFP, XFP, and GBIC Specifications 15454-SFP-GE+-LX=/ 15454E-SFP-GE+-LX= FC (1 and 2 Gbps), FICON, GE, HDTV –9.5 to –3 –20 to –3 (1 FC, 1GE, and 2 FC) ONS-SE-200-MM= ESCON –20.
A-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.3 A.3 General Card Specifications A.3 General Card Specifications This section pro vides po wer specificat ions and temperature ranges for all ONS 1545 4 cards.
A-7 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.3 A.3.1 Po wer Electrical Cards EC1-12 36.60 0.76 124.88 DS1-14 12.60 0.26 43.0 DS1N-14 12.60 0.26 43.0 DS1/E1-56 36.00 0.75 12 2.84 DS3-12 38.20 0.79 130.34 DS3/EC1-48 45 0.
A-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.3 A.3.2 Temperatur e A.3.2 Temperature Ta b l e A - 3 provides temperature ranges and p roduct names for ONS 15454 cards. Note The I-T emp symbol is displayed on the f aceplate of an I-T emp compliant card.
A-9 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.3 A.3.2 Tempe rature Electrical EC1-12 15454-EC1-12 15454-EC1-12-T DS1-14 15454-DS1-14 15454-DS1-14-T DS1N.
A-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.4 A.4 Common Control Card Specifications A.4 Common Control Card Specifications This section provides specifications for t he TCC2, TCC2P , XCVT , XC10G, XC-VXC-10G, an d AIC-I cards.
A-11 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.4 A.4.2 T CC2P Card Specifications – Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate) –.
A-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.4 A.4.3 XCVT Card Specifications – Underv oltage: Major alarm – Overv oltage: Major alarm • En viron.
A-13 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.4 A.4.5 XC-VXC - 10G Card Specificat ions A.4.5 XC-VXC-10G Card Specifications The XC-VXC-10G card has th.
A-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.4 A.4.7 AEP Specifications – Dual tone multifrequenc y (DTMF) signaling • User data ch annel (UDC) – Bit rate: 64 kbps, bidirectional – ITU-T G.
A-15 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.5 A.5 Electrical Ca rd Specifications – Number of outputs: 16 – Switched by opto MOS – T riggered b.
A-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.5 A.5.2 DS1-14 and DS1N-14 Card Specifications – T e rmination: Unbala nced coaxial cable – Input impe.
A-17 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.5 A.5.3 DS1/ E1-56 Card Specifications – T e rmination: W ire-wrap, AMP Champ – Input impedan ce: 100 ohms – Cable loss: M ax 655 feet ABAM #22 A W G – AIS: TR-TSY -000191 compliant – Po wer le vel: 12.
A-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.5 A.5.4 DS3/EC 1-48 Card Specifications – Bit rate: 1.544 Mbps ± 3 2 ppm (DS-1); 2.
A-19 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.5 A.5.5 DS3-12 and DS3N-12 Card Specifications – Bit rate: 44.
A-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.5 A.5.6 DS3i-N-12 Card Specifications • Output – Bit rate: 44.
A-21 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.5 A.5.7 DS3-12E and DS3N-12E Card Specifications – T e rmination: Unbala nced coaxial cable – Input impedan ce: 75 ohms +/– 5 percent – Cable loss: Maximum 137 m (450 ft ): 734A, RG59, 728A Maximum 24 m (79 ft): RG179 – AIS: ITU-T G.
A-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.5 A.5.7 DS3-12E a nd DS3N-12E Card Specificatio ns – Frame format: DS-3 ANSI T1.
A-23 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.5 A. 5.8 DS3X M-12 Ca rd Speci fications A.5.8 DS3XM-12 Card Specifications The DS3XM-12 card has the fol lowing specifications: • Input – Bit rate: 44.
A-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.5 A.5.9 DS3X M-6 Card Specifications A.5.9 DS3XM-6 Card Specifications The DS3XM-6 card has the follo wing specif ications: • Input – Bit rate: 44.736 Mb ps +/–20 ppm – Frame format: DS-3 ANSI T1.
A-25 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.5.10 FILL ER Card Specificat ions A.5.10 FILLER Card Specifications The FILLER cards hav e the follo .
A-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.2 OC3 IR/STM1SH 1310- 8 Card Specifications – Extinction Ratio: 8 .
A-27 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.3 OC12 IR/STM 4 SH 1310 Card Specifications – Dispersion tolerance: 96 ps/nm • Receiv er – Ma.
A-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.4 OC12 LR/STM4 LH 1310 Card Specifications – Minimum recei ver le vel: –28 dBm at BER 1 * 10 e x.
A-29 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.5 OC12 LR/S TM4 LH 1550 Card Specifications – Link loss budget : 25 dB – Receiv er input w av elength range: 12 80 to 1335 nm – Jitter tolerance: T elcordia GR-253/ITU-T G.
A-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.6 OC12 IR/STM4 SH 1310-4 Specifications • En vironmental – Operating temperature: C-T emp (15454.
A-31 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.7 OC48 IR 1310 Card Specifications • Operating humidity – 5 to 95 percent, non condensing • Dimensions – Height: 12.650 in. (321.3 mm) – W idth: 0.
A-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.8 OC48 LR 1550 Card Specifications – Height: 12.650 in. (321.3 mm) – W idth: 0.716 in . (18.2 mm) – Depth: 9.000 in. (2 28.6 mm) – W eight not including clam shell: 1.
A-33 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.9 OC48 IR/STM16 SH AS 1310 Card Specifications A.6.9 OC48 IR/STM16 SH AS 1310 Card Specifications The OC48 IR/STM16 SH AS 1310 card has the fo llo wing specif ications: • Line – Bit rate : 2.
A-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.11 OC48 ELR/STM 16 EH 100 GHz Card Specifications – Bit rate : 2.49 Gbp s – Code: Scrambled NRZ – Fiber: 1550-nm singl e-mode – Loopback modes: T erminal and facility – Connectors: SC – Compliance: T elcordia GR-253-CORE, ITU-T G.
A-35 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.12 OC48 EL R 200 GHz Card Specificat ions – Connectors: SC – Compliance: T elcordia GR-253-CORE, ITU-T G.
A-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.13 OC192 SR/STM 64 IO 1310 Card Specifications – Center wa veleng th accuracy: +/ – 0.
A-37 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.14 OC192 IR/STM64 SH 1550 Card Specifications – Maximum recei ver l ev el: –1 dBm at BER 1 * 10.
A-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.15 OC192 LR/S TM64 LH 1550 Card Specifications – T ransmitter: Cooled EA (Europea n accreditation).
A-39 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications – Minimum transmitter outpu t power: +7 dBm .
A-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.16 OC192 LR/STM64 LH ITU 15xx.xx Card Specifications In deployments with out a DCU: +/– 1200 ps/nm , with OSNR of 23 dB (0.
A-41 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.17 15454_M RC-12 Card Sp ecifications – 1538.98 +/– 0.040 n m, OC192 LR/STM64 LH ITU 1538. 98 – 1539.77 +/– 0.040 n m, OC192 LR/STM64 LH ITU 1539.
A-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.6 A.6.18 OC192SR1/STM64I O Short Reach Card Specifications – Receiv er: PIN PD – Receiv er input w av .
A-43 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.6 A.6.19 OC192/STM64 Any Reach Card Spec ifications – Operating humidity: 5 to 95 percent, non condensing • Dimensions – Height: 12.650 in. (321.3 mm) – W idth: 0.
A-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.7 A.7 Ethernet Card Specifications A.7 Ethernet Card Specifications This section includes sp ecifi cations for the E100T -12, E100T -G, E1000-2, E1000-2-G, CE-1000-4, CE-100T -8, G1K-4, ML100T -12, ML1000-2, and ML100X-8 cards.
A-45 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.7 A.7.4 E100 0-2-G Card Specifications – Operating humidity: 5 to 95 percent, non condensing • Dimensions – Height: 12.650 in. (321.3 mm) – W idth: 0.
A-46 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.7 A.7.7 G1K-4 Card Specifications – Operating humidity: 0 to 95 percent, non condensing • Dimensions – Height: 12.650 in. (321.3 mm) – W idth: 0.913 in .
A-47 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix A Hardware Sp ecifications A.8 A.7.10 ML100X -8 Card Specifications – Operating humidity: 5 to 95 percent, non condensing • Dimensions – Height: 12.650 in. (321.3 mm) – W idth: 0.
A-48 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix A Hardw are Specifications A.8 A.8.1 FC _MR-4 Card Specifications – Auto-detection • T ransmitter – Maximum transmitter output po.
B-1 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 APPENDIX B Administrative and Service States This appendix describes admini strati ve and ser vice states for Cisco ONS 15454 cards, ports, and cross-connects. For circuit st ate information, refer to Chapter 11, “Circuits and T unnels.
B-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix B Administrative and Service States B.2 B.2 Administrative States B.2 Administrative States Administrati ve states ar e used to manage service st ates. Administrati ve states consist of a PST and an SST .
B-3 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3 Se rvice State Transitions B.3 Service State Transitions This section describes the tr ansition from one se rvice state to the ne xt for cards, ports, and cross-connects.
B-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.1 Card Service Sta te Transitions OOS-A U,AINS & SWDL Restart completed. IS-NR Remov e the car d. OOS-A U,AINS & UEQ OOS-A U,AINS & UEQ Insert a v alid card.
B-5 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.2 Port and Cro ss-Connect Service State Tra nsitions B.3.2 Port and Cross-Connect Service State Transitions Ta b l e B - 5 lists the port and cross-connect service st ate transitions.
B-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.2 Port and Cr oss-Connect Service State Transitions T able B-5 ONS 1545 4 P or t and Cross- .
B-7 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.2 Port and Cro ss-Connect Service State Tra nsitions OOS-A U,AINS & FL T & OOG Alarm/condition is cleared.
B-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.2 Port and Cr oss-Connect Service State Transitions OOS-A UMA,FL T & LPBK & MT & OOG Release the loopback. OOS-A UMA,FL T & MT & OOG Alarm/condition is cleared.
B-9 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.2 Port and Cro ss-Connect Service State Tra nsitions OOS-MA,DSBLD Put the port or cross-connect in the IS administrati ve state. IS-NR Put the port or cr oss-connect in the IS,AINS administrative state.
B-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix B Administrative and Service States B.3 B.3.2 Port and Cr oss-Connect Service State Transitions.
C-1 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 APPENDIX C Network Element Defaults Note The terms "Unidirection al Path Swit ched Ring" and "U PSR" may appear in Cisco liter ature. These terms do not refer to using Cisco ONS 15 xxx products in a unidirectio nal path switched ring conf iguration.
C-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2 Card Default Settings settings e xcept those relating to protecti on (1+1 bidirectional switching, 1.
C-3 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.2 Threshold Defaults • Port—(FC_MR-4 cards only) Port line-le vel conf iguration, distance ext ension, and enhanced FC/FICON ISL settings.
C-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card Threshold defaults are def ined for near end and/or far end, at 15-minu te and one-day interv als.
C-5 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS1.pmthresholds.line.nearend.1day .CV 133400 (BPV count) 0 - 133315200 DS1.pmthresholds.line.nearend.1day .ES 648 (seconds) 0 - 86400 DS1.
C-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS1.pmthresholds.sts.f arend.15min.CV 15 (B3 count) 0 - 2160000 DS1.pmthresholds.sts.farend.1 5 min.ES 12 (seconds) 0 - 900 DS1.pmthresholds.
C-7 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.2 DS1/E1-56 Card Default Settings Ta b l e C - 2 lists the DS1/E1-56 card d efault setting s. T able C-2 DS1/E1 -56 Card Def ault Set tings Default Name Default V alue Default Domain DS1-E1-56.
C-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS1-E1-56.DS1-POR T .pmthresholds.ds1network .farend.15min.SESNE 10 ( seconds) 0 - 900 DS1-E1-56.DS1-POR T .pmthresholds.ds1network .
C-9 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS1-E1-56.DS1-POR T .pmthresholds.path.farend .1day .CV 132960 (BIP count) 0 - 27561600 DS1-E1-56.DS1-POR T .pmthresholds.path.farend .
C-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS1-E1-56.DS1-POR T .pmthresholds.sts.faren d.1day .SES 7 (seconds) 0 - 86400 DS1-E1-56.DS1-POR T .pmthresholds.sts.faren d.1day .U AS 10 (seconds) 0 - 86400 DS1-E1-56.
C-11 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS1-E1-56.E1-POR T .config.SaBit SA Bit 4 S A Bit 4, SA Bit 5, SA Bit 6, SA Bit 7, SA Bit 8 DS1-E1-56.E1-POR T .conf ig.SDBER 1E-7 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 DS1-E1-56.
C-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS1-E1-56.E1-POR T .pmthresholds.sts.farend.1day .ES 100 (seconds) 0 - 86400 DS1-E1-56.E1-POR T .pmthresholds.sts.farend.1day .FC 40 (count) 0 - 6912 DS1-E1-56.
C-13 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.3 DS-3 Card Default Settings Ta b l e C - 3 lists the DS-3 card def ault settings. T able C-3 DS-3 Card Def ault Settings Default Name Default Value Default Domain DS3.
C-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.4 DS3/EC1-48 Card Default Settings Ta b l e C - 4 lists the DS3/EC1-48 card defa ult settings. DS3.pmthresholds.sts.nearend. 1day .
C-15 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS3-EC1-48.DS3-POR T .pmthresholds.cpbitpath.nearend.15min.SA S 2 (seconds) 0 - 900 DS3-EC1-48.DS3-POR T .pmthresholds.cpbitpath.
C-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS3-EC1-48.DS3-POR T .pmthresholds.sts.farend.15min.SES 3 (seconds) 0 - 900 DS3-EC1-48.DS3-POR T .pmthresholds.sts.farend.15mi n.U AS 10 (seconds) 0 - 900 DS3-EC1-48.
C-17 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS3-EC1-48.EC1-POR T .pmthresholds.line.farend.1day .SES 4 (seconds) 0 - 86400 DS3-EC1-48.EC1-POR T .pmthresholds.line.farend.1 day .
C-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.5 DS3E Card Default Settings Ta b l e C - 5 lists the DS3E card defau lt settings. DS3-EC1-48.EC1-POR T .pmthresholds.sts1.nearend.
C-19 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS3E.pmthresholds.cpbitp ath.farend.1 day .CV 3820 (BIP count) 0 - 27561600 DS3E.pmthresholds.cpbitp ath.farend .1day .ES 250 (seconds) 0 - 86400 DS3E.
C-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.6 DS3I Card Default Settings Ta b l e C - 6 lists the DS3I card defa ult settings. DS3E.pmthresholds.pbitp ath.nearend.1day .
C-21 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS3I.pmthresholds.cpbitpath.f arend.15min.ESCP 25 (seconds) 0 - 900 DS3I.pmthresholds.cpbitp ath.farend.15min.SASCP 2 (seconds) 0 - 900 DS3I.
C-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.7 DS3XM-6 Card Default Settings Ta b l e C - 7 lists the DS3XM-6 card defaul t settings. DS3I.pmthresholds.pbit path.nearend.
C-23 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS3XM.pmthresholds.cpbitpat h.fare nd.1 5min.ES 25 (seconds) 0 - 900 DS3XM.pmthresholds.cpbitpat h.fa rend.15min .SAS 2 (seconds) 0 - 900 DS3XM.
C-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS3XM.pmthresholds.line.nearend.1day .CV 3865 (BPV count) 0 - 3715200 DS3XM.pmthresholds.line.nearend.1day .ES 250 (seconds) 0 - 86400 DS3XM.
C-25 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.8 DS3XM-12 Card Default Settings Ta b l e C - 8 lists the DS3XM-12 card def ault settings. DS3XM.pmthresholds.vt.f arend.15min.
C-26 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS3XM12.pmthresholds.cpbi tpath.farend.15 min.SAS 2 (seconds) 0 - 900 DS3XM12.pmthresholds.cpbi tpath.farend.15 min.SES 4 (seconds) 0 - 900 DS3XM12.
C-27 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card DS3XM12.pmthresholds.ds1p ath.far end.15min.ES 65 (seconds) 0 - 900 DS3XM12.pmthresholds.ds1p ath.far end.15min.ESA 25 (seconds) 0 - 900 DS3XM12.
C-28 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card DS3XM12.pmthresholds.li ne.nearen d.1d ay .SES 40 (seconds) 0 - 86400 DS3XM12.pmthresholds.pb itpath.nearend.15min.AISS 10 (seconds) 0 - 900 DS3XM12.
C-29 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.9 EC1-12 Card Default Settings Ta b l e C - 9 lists the EC1-12 card def ault settings. DS3XM12.pmthresholds.vt .farend.15min.
C-30 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card EC1.pmthresholds.line.f arend.1day .UAS 10 (seconds) 0 - 86400 EC1.pmthresholds.line.nearend.15mi n.CV 1312 (B2 count) 0 - 137700 EC1.
C-31 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.10 FC_MR-4 Card Default Settings Ta b l e C - 1 0 lists the FC_MR-4 card def ault settings. EC1.pmthresholds.sts1.near end.
C-32 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.11 Ethernet Card Default Settings Ta b l e C - 1 1 lists the G1000 (G1K-4), ML1000, ML10 0T , ML-100X-8, and CE-100T -8 card default settings.
C-33 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.12 OC-3 Card Default Settings Ta b l e C - 1 2 lists the OC-3 (OC3 IR 4/STM1 SH 1310) card default settings. T able C-12 OC-3 Card Def ault Set tings Default Name Default V alue Default Domain OC3.
C-34 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC3.pmthresholds.lin e.nearend.1day .SES 4 (seconds) 0 - 86400 OC3.pmthresholds.lin e.nearend.1day .UAS 10 (seconds) 0 - 8640 0 OC3.
C-35 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.13 OC3-8 Card Default Settings Ta b l e C - 1 3 lists the eight-port OC3- 8 (OC3 IR/STM1 SH 1310 -8) card default setti ngs.
C-36 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC3-8.conf ig.line.AlsReco veryPuls eI nterv al 100 (seconds) 60 - 300 OC3-8.conf ig.line.PJStsMon# 0 (STS #) 0 - 3 OC3-8.config.line.
C-37 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC3-8.pmthresholds.line.f arend.15min.ES 87 (seconds) 0 - 900 OC3-8.pmth resholds.line.farend.15 min.FC 10 (count) 0 - 72 OC3-8.pmthresholds.
C-38 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC3-8.pmthresholds.sts1.near end.15 min.PJCD IFF 60 (count) 0 - 14400000 OC3-8.pmthresholds.sts1.near end.15 min.PJCS-PDET 100 (seconds) 0 - 900 OC3-8.
C-39 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.14 OC-12 Card Default Settings Ta b l e C - 1 4 lists the OC-12 (OC12 IR/STM4 SH 131 0, OC12 LR/STM4 LH 1310, and OC12 LR/STM4 LH 1550) card defaul t settings.
C-40 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC12.pmthresholds.line.nearen d.15min.CV 5315 (B2 count) 0 - 552600 OC12.pmthresholds.line.nearen d.15min.ES 87 (seconds) 0 - 900 OC12.
C-41 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC12.pmthresholds.sts1.nearen d.15min.SES 3 (seconds) 0 - 900 OC12.pmthresholds.sts1.nearen d. 15min.U AS 10 (seconds) 0 - 900 OC12.
C-42 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.15 OC12-4 Card Default Settings Ta b l e C - 1 5 lists the four -port OC12-4 (OC12 IR/STM4 SH 1310-4) card defa ult settings.
C-43 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC12-4.conf ig.line.SDBER 1E-7 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 OC12-4.conf ig.line.Send<FF>DoNotUse F A LSE F ALSE when SendDoNotUse TR UE; F ALSE, TR UE when SendDoNotUse FA L S E OC12-4.
C-44 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC12-4.pmthresholds .section.nearend.15min.CV 10000 (B1 count) 0 - 553500 OC12-4.pmthresholds.secti on.nearend.15min.ES 500 (seconds) 0 - 900 OC12-4.
C-45 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC12-4.pmthresholds. sts12c.nearend.15min.NPJC-PGEN 60 (count) 0 - 7200000 OC12-4.pmthresholds. sts12c.nearend.15min.PJCDIFF 60 (count) 0 - 14400000 OC12-4.
C-46 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.16 OC-48 Card Default Settings Ta b l e C - 1 6 lists the OC-48 (OC48 IR 1310, OC48 LR 1550, OC48 IR/STM16 SH AS 1310, OC48 LR/STM16 LH AS 1550, OC48 ELR /STM16 EH 100 GHz, and OC48 ELR 20 0 GHz) card default settings.
C-47 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC48.pmthresholds.line.f arend.15min.FC 10 (count) 0 - 72 OC48.pmthresholds.line.f arend.15min.SES 1 (seconds) 0 - 900 OC48.pmthresholds.
C-48 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC48.pmthresholds.section .nearend.15min.SEFS 500 (seconds) 0 - 900 OC48.pmthresholds.section .nearend.15min.SES 500 (seconds) 0 - 900 OC48.
C-49 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC48.pmthresholds.sts12c- 48c.nearend .15min.PJCS-PDET 100 (seconds) 0 - 900 OC48.pmthresholds.sts12c- 48c.nearend .15min.PJCS-PGEN 100 (seconds) 0 - 900 OC48.
C-50 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.17 OC-192 Card Default Settings Ta b l e C - 1 7 lists the OC-192 (OC192 SR/STM64 IO 1310, OC19 2 LR/STM64 LH ITU 15xx.xx, OC192 IR/STM64 SH 1550, and OC192 LR/STM6 4 LH 1550) card defaul t settings.
C-51 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC192.physicalthresh olds .alarm.OPR-HIGH 200 (%) OPR-LOW , OPR-LO W + 1.0, OPR-LO W + 2.0 .. 255.0 OC192.physicalthresh olds.alarm.
C-52 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC192.pmthresholds.line.nearend.15mi n.PSC-R 1 (count) 0 - 600 OC192.pmthresholds.line.nearend.15mi n.PSC-S 1 (count) 0 - 600 OC192.
C-53 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC192.pmthresholds.sts1.nearend.15min.PJCS- PDET 100 (seconds) 0 - 900 OC192.pmthresholds.sts1.nearend.15min.PJCS- PGEN 100 (seconds) 0 - 900 OC192.
C-54 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC192.pmthresholds.sts12c-192c.nearend. 1day .PJCS-PDET 9600 (seconds) 0 - 691200000 OC192.pmthresholds.sts12c-192c.nearend. 1day .
C-55 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card C.2.3.18 OC192-XFP Default Settings Ta b l e C - 1 8 lists the OC192-XFP def ault settings. T able C-1 8 OC192-XFP Def ault Set tings Default Name Default V alue Default Domain OC192-XFP .
C-56 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC192-XFP .physicalthresholds.warning.15min.OP T -HIGH 120 (%) OPT -LO W , OPT -LO W + 1.0, OPT -LO W + 2.0 .. 255.0 OC192-XFP .physicalthresholds.
C-57 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC192-XFP .pmthresholds.line.nearend.1d ay .FC 40 (count) 0 - 6912 OC192-XFP .pmthresholds.line.nearend.1d ay .PSC 5 (count) 0 - 57600 OC192-XFP .
C-58 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card OC192-XFP .pmthresholds.sts1.nearend.15min.PJCS-PGEN 100 (seconds) 0 - 7200000 OC192-XFP .pmthresholds.sts1.nearend.15min.PPJC-PDET 60 (count) 0 - 7200000 OC192-XFP .
C-59 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card OC192-XFP .pmthresholds.sts12c-192c.nearend.15mi n.PPJC-PGEN 60 (count) 0 - 7200000 OC192-XFP .pmthresholds.sts12c-192c.nearend.15min.
C-60 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card C.2.3.19 MRC-12 Card Default Settings Ta b l e C - 1 9 lists the MRC -12 card default settings. OC192-XFP .pmthresholds.sts3c-9c.nearend.
C-61 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.config.oc12.line.Sy ncMsgIn TR UE F ALSE, TR UE MRC-12.conf ig.oc12.sts.IPPMEnabled F ALSE TRUE, F ALSE MRC-12.conf ig.oc3.
C-62 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card MRC-12.conf ig.oc48.line. State IS,AINS IS, OOS,DSBLD, OOS,MT , IS,AINS MRC-12.config.oc48.line.Sy ncMsgIn TR UE F A LSE, TR UE MRC-12.
C-63 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.physicalthreshold s.oc3.warning.15mi n.LBC-HIGH 200 (%) LBC-LO W , LBC-LOW + 1.0, LBC-LO W + 2.0 .. 255.0 MRC-12.physicalthresholds.
C-64 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card MRC-12.physic althresholds.oc48 .warning.1day .OPR-H IGH 200 (%) OPR-LO W , OPR-LO W + 1.0, OPR-LO W + 2.0 .. 255.0 MRC-12.physic althresholds .
C-65 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.pmthresholds.oc12.secti on.nearend.15min .SES 500 (seconds) 0 - 900 MRC-12.pmthresholds.oc12.secti on.nearend.1day .CV 100000 (B1 count) 0 - 53136000 MRC-12.
C-66 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card MRC-12.pmthresholds.oc12.sts1.nearend . 1day .PPJC-PGEN 5760 (count) 0 - 691200000 MRC-12.pmthresholds.oc12.sts1.neare nd.1day .SES 7 (seconds) 0 - 86400 MRC-12.
C-67 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.pmthresholds.oc12.sts12 c.nearend.1day .U AS 10 (seconds) 0 - 86400 MRC-12.pmthresholds.oc12.sts3c-9c.f arend.15min.CV 25 (B3 count) 0 - 2160000 MRC-12.
C-68 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card MRC-12.pmthresholds.oc3.line.f arend.15min.ES 87 (seconds) 0 - 900 MRC-12.pmthresholds.oc3.line.f arend.15min.FC 10 (count) 0 - 72 MRC-12.
C-69 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.pmthresholds.oc3.sts1.f arend.1day .CV 125 (B3 count) 0 - 207360000 MRC-12.pmthresholds.oc3.sts1.f arend.1day .ES 100 (seconds) 0 - 86400 MRC-12.
C-70 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card MRC-12.pmthresholds.oc3.sts3c .farend.1day .FC 40 (count) 0 - 6912 MRC-12.pmthresholds.oc3.sts3c .farend.1day .SES 7 (seconds) 0 - 86400 MRC-12.
C-71 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.pmthresholds.oc48.lin e.farend.1day .U AS 10 (s econds) 0 - 86400 MRC-12.pmthresholds.oc48.lin e.nearend.15min.CV 21260 (B2 count) 0 - 2212200 MRC-12.
C-72 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.2 C.2.3 Defaults by Card MRC-12.pmthresholds.oc48.sts1.f arend.15min.ES 12 (seconds) 0 - 900 MRC-12.pmthresholds.oc48.sts1.f arend.15min.FC 10 (count) 0 - 72 MRC-12.
C-73 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.2 C.2.3 D efaults by Card MRC-12.pmthresholds.oc48.sts12c-48c.f arend.15min.SES 3 (seconds) 0 - 900 MRC-12.pmthresholds.oc48.sts12 c-48c.farend.15min.U AS 10 (seconds) 0 - 900 MRC-12.
C-74 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.3 C.3 Node Default Settings C.3 Node Default Settings T able C-20 on page C-76 lists the no de-lev el defa ult settings for the Cisco ONS 15454.
C-75 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.3 C.3 Node Default Settings • General s ettings— Set general n ode manage ment defaults, including w.
C-76 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.3 C.3 Node Default Settings • BITS T iming settings—Set th e AIS threshold, Admin SSM, coding, f acility type, framin g, state, and line b uild-out (LBO) set tings for b uilding inte grated timing supply 1 (BITS-1) and BITS2 timing.
C-77 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.3 C.3 Node Default Settings NODE.general.T imeZone (GMT -08:00 ) Pacif ic T ime (US & Canada), Ti j u a n a (For applicable ti me zones, see T able C-21 on page C-83 .
C-78 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.3 C.3 Node Default Settings NODE.osi.tarp.LDB TRUE F ALSE, TR UE NODE.osi.tarp.LDBEntry 5 (min) 1 - 10 NODE.osi.tarp.LDBFlush 5 (min) 0 - 1440 NODE.osi.tarp.
C-79 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.3 C.3 Node Default Settings NODE.security .dataComm.DefaultT CCEthernetIP 10.0.0.1 IP Address NODE.security .dataComm.Defa ultTCCEthernetIPNetmask 24 (bits) 8, 9, 10 .
C-80 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.3 C.3 Node Default Settings NODE.security .lanAccess .LAN Access (May disconnect CTC from node) Front & Backplane No LAN Access, Front Only , Backplane Only , Front & Backplane NODE.
C-81 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.3 C.3 Node Default Settings NODE.security .passwordAging.superuser .W arningPeriod 5 (d ays) 2 - 20 NODE.security .passwordChange.CannotCha ngeNe wPassw ord F ALSE TR UE, F ALSE NODE.
C-82 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.3 C.3 Node Default Settings NODE.timing.bits-1.F raming ESF ESF , D4 when FacilityT ype DS1; N/A when Faci lityT ype 64kHz+8kHz NODE.timing.bits-1.F ramingOut ESF ESF , D4 when FacilityT ypeOut DS1; N/A when FacilityT ypeOut 6MHz NODE.
C-83 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.3 C.3.1 Time Zones C.3.1 Time Zones Ta b l e C - 2 1 lists the time zones that appl y for node time zone defaul ts.
C-84 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.3 C.3.1 Time Zones GMT -05:00 (GMT -05:00) Bogota, Lima, Quito GMT -05:00 (GMT -05:00) Eastern T ime (US .
C-85 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 Appendix C Network Element De faults C.3 C.3.1 Time Zones GMT+03:30 (GMT+03:30) T ehran GMT+04:00 (GMT+04:00) Ab u Dhabi, Mauritius, Muscat GMT.
C-86 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 Appendix C Network Eleme nt Defaults C.4 C.4 CTC Default Settings C.4 CTC Default Settings T ab le C-22 on page C-86 lists the CTC-le ve l default setti ngs for the Cisco ONS 15454.
IN-1 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 INDEX Numerics 1+1 optical port prot ection creating linear ADMs 12-19 description 7-13 1:1 electrical card prot ection description 7-2 electri.
Index IN-2 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 modify 14-10 save 14-11 alarms change defaul t severities see alarm p rofiles profiles se e alarm profiles traps se e SNMP alarm suppresse.
Index IN-3 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 bandwidth capacity 12-8 DRI 12-14 fiber connections 12-12 four-fiber 12-5 increasing the traffic speed 12-24 maximum node number 12-2 pro.
Index IN-4 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 see also STS see also VCA T circuits see also VT1.5 signals attributes 11-2 automatic routing 11-26 autorange 11-2 constraint-based routin.
Index IN-5 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 D database see also T CC2 ca rd see also T CC2P ca rd description 8-17 MAC address 1-13 revert 8-18 data cards see Ethernet cards data co.
Index IN-6 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 EIA requirement 1-14 factory defaults C- 4 port status 3-9 slot compatibili ty 3-7 specifications A-16 DS3/EC1-48 card see also UBI C-V EI.
Index IN-7 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 factory defaults C-25 ported mode 3-27 portless mode 3-27, 7-4, 11-15 port status 3-31 slot compatibili ty 3-27, 3-29 specifications A-23.
Index IN-8 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 cross-connect cards 3-5 description 3-4 EIA compatibility 1-15, 1-16 EIA requirement 1-14 factory defaults C- 29 performance monitoring 15.
Index IN-9 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 remote monitoring (RMON) 16-16 Ethernet cards see also CE-1000-4 card see also CE-100T-8 card see also E1 000-2 card see also E1 000-2-G .
Index IN-10 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 F facility data link 15-18 factory defaults see network element defaults fan-tray air filter se e air filter fan-tray assembly descriptio.
Index IN-11 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 gateway on routing table 13-24 Proxy ARP-enabled 13-2, 13-4 returning MAC address 13-4 gateway n etwork e lement see GN E gateway se tti.
Index IN-12 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 software and hardware matrix 1-73 IOS parameter 15-7 IP dual IP addresses using secure mode 13-20 environments 13-1 networking 13-1 to 13.
Index IN-13 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 link consol idation description 8-13 icons 8-14 link cont rol protocol 13-30 link-state packet 13-35 LOFC parameter 15-7 login node grou.
Index IN-14 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 N NE defaults see netw ork element defaults Netscape 8-3 network conversions 12-25 network element defaults description C-1 card default .
Index IN-15 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 port status 4-15 slot compatibili ty 4-14 specifications A-29 topologies 4-14 OC192/STM64 Any Reach card see OC192-X FP card OC192 IR/ST.
Index IN-16 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 factory defaults C-46 LEDs 4-27 port status 4-27 slot compatibili ty 4-26 specifications A-34 topologies 4-26 OC48 ELR 200 GHz cards See .
Index IN-17 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 OPT-MAX parameter 15-8 OPT-MIN parameter 15-8 optocoupler isol ation 1-56 OPT parameter 15-8 OPWR-AVG parameter 15-8 OPWR-MAX para meter.
Index IN-18 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 monitoring 2-31 specifications A-3 supply 1-63 PPJC-Pdet parameter 15-4 PPJC-PDET-P parameter 15-8 PPJC-Pgen parameter 15-4 PPJC-PGEN-P p.
Index IN-19 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 TCC2P port description 2-12 roll automatic 11-38 dual 11-40 manual 11-38 one cross-connection 11-40 path 11-38 protected circuits 11-42 .
Index IN-20 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 four-node config uration 12-21 mounting 1-5 simple network management protocol see SNMP SMB EIA balun re quirement 1-38 card protection d.
Index IN-21 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 32-bit 13-25 access to nodes 13-8 destination host or network 13-24 superuser assign superuser privil eges to provisioning users 9-6 cha.
Index IN-22 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 system timing 2-12 temperat ure ranges A-8 TCP/IP and OSI mediation 13-40 DCN communication 13-29 TCC2P access 2-12 TDM 11-12 Telcordia a.
Index IN-23 Cisco ONS 15454 Reference Manua l, R7.0 78-17191-01 See also UBIC-H cables UBIC-V cables connector pi ns 1-39, 1-51, 1-52 description 1-39 UBIC-V EIA card protection de scription 7-12 conn.
Index IN-24 Cisco ONS 15454 Reference Manual, R7.0 78-17191-01 X XC10G card bandwid th 11-12 card-level LEDs 2-21 description 2-18 functionality 2-19 hardware compatibility 1-75 power requirements A-6.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Cisco Systems 15454 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Cisco Systems 15454 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Cisco Systems 15454, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Cisco Systems 15454 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Cisco Systems 15454, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Cisco Systems 15454.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Cisco Systems 15454. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Cisco Systems 15454 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.