Manuel d'utilisation / d'entretien du produit door opener du fabricant Chamberlain
Aller à la page of 36
This Operator Features the Enhanced Radio Receiver Built on Board O O W W N N E E R R ’ ’ S S M M A A N N U U A A L L G G H H I I N N D D U U S S T T R R I I A A L L D D U U T T Y Y C C O O M M M .
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.
Before beginning your installation check that all components were provided. CARTON INVENTORY OPERA TOR DIMENSIONS 3 14.13" 13.25" 14.00" Hand Chain W heel See N ote #1 See N ote #2 A X .
4 OPERA TOR SPECIFICA TIONS SAFETY DISCONNECT : . . . . . . . . . .Floor level chain hoist with electrical interlock for manual door operation. CLUTCH (Optional): . . . . . . . . . . .Adjustable torque limiter type SAFETY PHOTO EYES (Optional CPS-L): Through beam or retro reflective devices used to provide non-contact safety protection.
5 PREP ARA TION It is imperative that the wall or mounting surface provide adequate support for the operator . This surface must: a. Be rigid to prevent play between operator and door shaft. b. Provide a level base. c. Permit the operator to be fastened securely and with the drive shaft parallel to the door shaft.
6 INST ALL A TION IMPORT ANT NOTE: Before your operator is installed, be sure the door has been properly aligned and is working smoothly . The operator may be wall mounted or mounted on a bracket or shelf. If necessary , refer to the preparation on page 5.
7 MANUAL OPERATION This operator has provisions for manually operating the door in case of emergency or power failure. These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used.
8 ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) PHOTO EYES & SENSING EDGES Sensing devices provided for door industry type operators with an isolated normally open (N.O.) dry contact output are compatible with your operator . This includes pneumatic and electric edges, and through beam and retro reflective photo eyes.
9 ADJUST TORQUE LIMITER CLUTCH (OPTIONAL MODIFICATION) 1. Loosen set screws on clutch nut. 2. Back off clutch nut until there is ver y little tension on the clutch spring. 3. Tighten clutch nut gradually until there is just enough tension to permit the operator to move the door smoothly but to allow the clutch to slip if the door is obstructed.
10 T o reduce the risk of SEVERE INJURY or DEA TH: • ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch.
11 CONTROL ST A TION WIRING AND INST ALL A TION CONTROL WIRING CONNECTIONS 1. Connect control wires to the P1 terminal block located on the logic board as shown. 2. Connect conduit with all control wires through the conduit hole in the electrical box enclosure marked with the label shown below .
12 ST ANDARD POWER & CONTROL CONNECTION DIAGRAMS Open Close Stop Maintenance Alert LED Open/Close Single Button (WH) (RD) Sensing Edge CPS-L & CPS-LN4 T imer Defeat Switch R1 R2 R3 Radio Contr.
U1 POWER TIMER DEFEA T MAS 4 MRT 1 RADIO MID 2 TIMER TIMER ENABLE TT S FSTS E2 RELA Y A RELA Y B D1 DIAG C2 B2 PROG 3 24V AC 24V AC TIMER DEFEA T CMN MAS EYES EDGE OPEN CLOSE STOP CMN SBC 11 10 9 14 1.
U1 POWER TIMER DEFEA T MAS 4 MRT 1 RADIO MID 2 TIMER TIMER ENABLE TT S FSTS E2 RELA Y A RELA Y B D1 DIAG C2 B2 PROG 3 24V AC 24V AC TIMER DEFEA T CMN MAS EYES EDGE OPEN CLOSE STOP CMN SBC 11 10 9 14 1.
15 LOGIC BOARD U1 POWER TIMER DEFEA T MAS 4 MRT 1 RADIO MID 2 TIMER TIMER ENABLE TT S FSTS E2 RELA Y A RELA Y B D1 DIAG C2 B2 PROG 3 24V AC 24V AC TIMER DEFEA T CMN MAS EYES EDGE OPEN CLOSE STOP CMN S.
16 PROGRAMMING DETERMINE AND SET WIRING TYPE Read the descriptions of the different wiring types to determine which setting will be correct for each application. SET THE SELECTOR DIAL TO THE DESIRED WIRING MODE: NOTE: For failsafe wiring you must also set failsafe switch to F AILSAFE.
17 PROGRAMMING FAILSAFE WIRING TYPES TYPE TS Momentary contact to open, close, and stop with open override and Timer T o Close. Every device that causes door to open, including a reversing device, activates the Timer T o Close. Auxiliary controls can be connected to open input to activate the Timer T o Close.
18 PROGRAMMING SINGLE BUTTON CONTROL (SBC) REMOTE This function programs a remote as a wireless single button control. In B2 mode, operation is OPEN / STOP / CLOSE / REVERSE / STOP . In C2 mode, operation is OPEN / STOP/ Constant pressure to CLOSE / STOP on release.
19 OPEN CLOSE STOP Open Close Stop U1 POWER TIMER DEFEA T MAS 4 MRT 1 RADIO MID 2 TIMER TIMER ENABLE TT S FSTS E2 RELA Y A RELA Y B D1 DIAG C2 B2 PROG 3 24V AC 24V AC TIMER DEFEA T CMN MAS EYES EDGE O.
20 PROGRAMMING MAINTENANCE ALERT SYSTEM (MAS) Feature: An internal cycle counter will activate a flashing LED on the 3-button control station when the preset number of cycles or months has elapsed (whichever occurs first). Setting this feature is optional.
21 Operation w ill v ary depending on w iring type SELECTOR DIAL Operation w ill v ary depending on w iring type SELECTOR DIAL PROGRAMMING OPEN MID STOP Feature: The mid stop feature is to open the door to a preset point prior to the fully open position.
22 TIMER TO CLOSE Program Timer to Close by Example (Method 2): T o Program: 1. Close the door . 2. T urn the selector dial to PROGRAM. 3. Press and hold TIMER button for 5 seconds until TIMER LED flashes. 4. Press the OPEN button and wait for the door to reach full open or mid stop position.
23 MAXIMUM RUN TIMER (MRT) Feature: The operator can learn the time it takes to open or close the door plus an additional 10 seconds. Benefit: If the operator does not meet its open or close limit within the set time it will stop, limiting damage to the door and operator .
24 RESETTING FACTORY DEFAULTS - CLEARING MEMORY T o reset most of the user installed settings back to factor y defaults: 1. T urn the selector dial to DIAGNOSTIC. 2. Press and hold the STOP button for 5 seconds. The MAS LED will flash momentarily when the factory defaults have been restored.
25 DIAGNOSTIC CHART The logic board has several LEDs to assist in the installation and troubleshooting of the operator . The following chart should assist in verifying the operator is functioning properly . T urn the selector dial to DIAGNOSTIC to keep the door from moving while troubleshooting.
26 TROUBLESHOOTING GUIDE THE OPERA TOR WILL NOT RESPOND TO ANY COMMANDS POWER LED IS NOT ON STOP BUTTON LED IS NOT ON THE DOOR WILL MOVE ABOUT A FOOT THEN STOP . AFTER STOPPING, ONL Y CONST ANT PRESSURE COMMANDS WILL MOVE THE DOOR THE DOOR WILL MOVE MOST OF THE WA Y TOWARDS A LIMIT THEN STOP .
27 TROUBLESHOOTING ERROR CODES Logic 3.0 operators incorporate a self diagnostic feature built into the MAS LED. In addition to indicating when routing maintenance is due, the MAS LED can be used to troubleshoot some problems with the operator .
28 TROUBLESHOOTING RADIO FUNCTIONALITY The error codes will display at the radio LED. NOTE: Radio receiver is compatible with 315MHz remotes ERROR CODE SYMPTOM DISPLA Y POSSIBLE PROBLEM CORRECTION R1 No response from the remote Quick Flash Unlearned remote - T r y re-learning the A user tries to use a remote, remote (page 18).
29 This page intentionally left blank..
30 ELECTRICAL BOX 6 9 8 1 4 7 5 2 11 10 3 K1 K2 (K72-10047-1) (K72-12515-1) (K72-10047).
31 ELECTRICAL BOX LOGIC (VER 3.0) For replacement of electrical box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements.
32 MODEL GH 1 3 4 K5 (K75-12 8 29) (K75-12 8 30) (K75-12 8 31) (K75-12 8 32) (K75-12 8 33) K1 (K75-125 8 4) (K75-125 8 5) (K75-125 8 6) 2 5 K4 (K75-30737) 6 17 1 8 19 20 7 K3 (K72-127 8 9) 13 13 8 9 1.
33 REP AIR PARTS KITS - MODEL GH SERVICE KITS ITEM P ART # DESCRIPTION K1 K75-12584 Brake kit - 115 Volt models K75-12585 Brake kit - 230-460 Volt models K75-12586 Brake kit - 575 Volt models Complete.
34 OPERA TOR NOTES.
35 OPERA TOR NOTES.
CONTROL CONNECTION DIAGRAM IMPORTANT NOTES: 1. The 3-Button Control Station provided must be connected for operation. 2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Chamberlain door opener c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Chamberlain door opener - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Chamberlain door opener, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Chamberlain door opener va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Chamberlain door opener, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Chamberlain door opener.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Chamberlain door opener. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Chamberlain door opener ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.