Installation and Operating Instructions for Gas Log Heaters Models: UVHK23MP , UVHK29MN, UVHK31MP , UVHK36MN Mod els wi th “N” af ter th e m ode l n umb er use na tur al gas ; m ode ls wit h “ P” aft er the mo del nu mbe r u se pro pan e ( LP) ga s.
2 20008056 Important Information .................................................................................................................. 3 Important Safeguards ................................................................................
3 20008056 Important Information W ARNING: Any change to this heater or its con- trols can be dangerous. In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber .
4 20008056 The National Fuel Gas Code, ANSI Z223.1/NFP A 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.
5 20008056 W ARNING This appliance is for installation in a solid-fuel burning masonry , fireplace with a working flue, a U.L.-127 listed manufactured solid-fuel burn- ing fireplace, in any Majestic ventless firebox, or in any listed ventless firebox enclosure certified to I.
6 20008056 W ARNING: Refer to the above table to ensure that your log set is certified to be used in the CFM Corporation V ent-Free firebox you have purchased.
7 20008056 Provisions for Adequate Combustion and V entilation Air W ARNING: This heater shall not be installed in a confined space or unusually tight construc- tion unless provisions are provided for adequate combustion and ventilation air . T oday’s homes are built more energy efficient than ever .
8 20008056 L W D T104 flue damper 10/27/03 djt Flue Damper Closed for Unvented Operation and Maximum Heat Output Flue Damper Locked Open to a Minimum V enting Area of 34 sq. in. (for areas where unvented products are not permitted) NOTE: For round flue opening minimum flue diameter (D) - 7”.
9 20008056 Installation Unpacking Open the carton and remove the logs and the chassis. Remove each of the logs by gripping at either end of the log while avoid- ing any undue pressure. Please note that the logs have been marked for positive identification.
10 20008056 42" 16" T105 Minimum clearance to walls & ceiling 10/27/03 djt Fig. 4A Minimum clearance to wall and ceiling. 10" 8" 6" 1 ¹⁄₈ " 10" Min. 15" Min. 19" Min. 23" Min. 27" Min.
1 1 20008056 Gas Connection Check Gas T ype. Use only the gas type indicated on the heater ’s rating plate. If the gas type indicated on the plate is not your type of gas supply , DO NOT INST ALL. Contact your dealer for the proper model. W ARNING DANGER OF PROPERTY DAMAGE, BODIL Y INJUR Y OR DEA TH.
12 20008056 NOTE: T o determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the gas system.
13 20008056 For Y our Safety , Read Before Lighting W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
14 20008056 Flame Check A periodic visual check of the flames should be made. The pilot flame should always be present when the appliance is in opera - tion.
15 20008056 Positioning Logs The logs must be positioned ONL Y as illustrated in Figures 12, 13 and 14 • Position the front log so that the large notch in the underside of the right end of the log fits securely and rests on the sheet metal control cover as shown in Figure 15.
16 20008056 Charred Oak Logset Fig. 13 Charred oak logset positions. W ARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically ap - proved with this heater , may result in property damage or personal injury .
17 20008056 T100 log notch on valve cover 10/15/03 djt V alve Cover T100 Fig. 15 Position log so notch fits securely and rests on valve cover . T101 secure front log 10/15/03 djt Front Log End Bar Should Fit in V -Shaped Depression in the Bark T101 Fig.
18 20008056 Servicing Repair and replacement work should only be done by a quali- fied service technician. Always shut off the gas supply and make sure the appliance is cool before beginning any service operation. Always check for gas leaks after servicing.
19 20008056 LIMITED 2/20 YEAR W ARRANTY For Majestic Fireplaces V ent-Free Gas Appliances CFM Corporation (Company) extends the warranties speci- fied in paragraphs A and B below with respect to its .
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté CFM UVHK23MP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du CFM UVHK23MP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation CFM UVHK23MP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le CFM UVHK23MP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le CFM UVHK23MP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du CFM UVHK23MP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le CFM UVHK23MP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei CFM UVHK23MP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.