Manuel d'utilisation / d'entretien du produit 2467, 2468 du fabricant CFM Corporation
Aller à la page of 28
INST ALLER / CONSUMER SAFETY INFORMA TION 30002008 7/04 Rev . 3 PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROP- ERTY DAMAGE, PERSONAL IN- JUR Y OR LOSS OF LIFE.
2 2 Dutchwest Natural Vent Gas Heater 30002008 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation.
3 Dutchwest Natural Vent Gas Heater 30002008 The Dutchwest Natural V ent Room Heater , Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Alti- tudes.
4 4 Dutchwest Natural Vent Gas Heater 30002008 C L V alve Inlet C L V alve Inlet 17" (419mm) 23" (584mm) 28 ³⁄₈ " (721mm) 4 ³⁄₈ " (1 1 1mm) 6 ³⁄₄ " (172mm) 12 ¹⁄₂ " (318mm) 24 ¹⁄₂ " (622mm) See Page 5 for Flue Collar Centerline Dimensions.
5 Dutchwest Natural Vent Gas Heater 30002008 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the sheet metal rear skirt.
6 6 Dutchwest Natural Vent Gas Heater 30002008 Venting Requirements and Options The Dutchwest must be properly connected to a listed 4” (100mm) Type B venting system or to an approved Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney systems is required.
7 Dutchwest Natural Vent Gas Heater 30002008 Passing Through a Combustible Wall or Ceiling An approved pass-through device is always required when a vent passes through a combustible wall or ceiling. Check with the maker of the vent system for the correct listed devices that are available.
8 8 Dutchwest Natural Vent Gas Heater 30002008 Outer Shroud Slot Inner Shroud Slot ST194 Fig. 11 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws. Left Air Duct Fan Inner Shroud ST720 Fig. 10 Attach snapstat wire assembly to inside of inner shroud with clamp screws.
9 Dutchwest Natural Vent Gas Heater 30002008 Snapstat Left Air Duct ST671 Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection.
10 10 Dutchwest Natural Vent Gas Heater 30002008 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Dutchwest may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on Page 23.
11 Dutchwest Natural Vent Gas Heater 30002008 Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a CFM Specialty Home Products Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model.
12 12 Dutchwest Natural Vent Gas Heater 30002008 Install the Stove Front Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 23) The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body .
13 Dutchwest Natural Vent Gas Heater 30002008 Operation Your First Fire Read these instructions carefully and familiarize yourself with the burner controls.
14 14 Dutchwest Natural Vent Gas Heater 30002008 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.
15 Dutchwest Natural Vent Gas Heater 30002008 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
16 16 Dutchwest Natural Vent Gas Heater 30002008 Conversion Precautions Conversion must be completed only by qualified personnel. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance.
17 Dutchwest Natural Vent Gas Heater 30002008 Pilot Hood Pilot Bracket CO105a Fig. 31 Remove pilot hood. Index T ab Snap Ring Allen Wrench CO106a Fig. 32 Remove pilot orifice. • Remove pilot orifice with allen wrench. (Fig. 32) • Install the conversion orifice.
18 18 Dutchwest Natural Vent Gas Heater 30002008 Conversion to LP Input (BTU/h) Air Shutter Kit # Front Part # Rear Part # Minimum Maximum Setting 000-5022 #69 / .
19 Dutchwest Natural Vent Gas Heater 30002008 Maintenance Y our Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician.
20 20 Dutchwest Natural Vent Gas Heater 30002008 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced.
21 Dutchwest Natural Vent Gas Heater 30002008 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF- 2, 200 ° C WIRE OR ITS EQUIV ALENT .
22 22 Dutchwest Natural Vent Gas Heater 30002008 Dutchwest Natural V ent Gas Heater Models 2467, 2468 Ref. Description Part Number 1. SDV30 Log Set Assembly 20003458 1a. Rear Log 20003459 1b. Right Log 20003460 1c. Left Log 20003461 2. Small Lava Rock Package 57897 3.
23 Dutchwest Natural Vent Gas Heater 30002008 Dutchwest Natural V ent Gas Heater (continued) Models 2467, 2468 Ref. Description Part Number 6. Door , DW Gas 30001929 7. Leg, DW Gas 30001930 8. End, Rt - DW Gas 30001927 9. End, Lt - DW Gas 30001926 10.
24 24 Dutchwest Natural Vent Gas Heater 30002008 Decorative Rings 4” brass or black rings are available to add a decorative touch to the exposed stove pipe.
25 Dutchwest Natural Vent Gas Heater 30002008.
26 26 Dutchwest Natural Vent Gas Heater 30002008 BASIC WARRANTY CFM Specialty Home Products Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace.
27 Dutchwest Natural Vent Gas Heater 30002008 GARANTIE DE BASE La société CFM Specialty Products (ci-après la « Société ») garantit votre nouveau poêle/foyer au gaz Dutchwest contre tous défa.
© CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www .vermontcastings.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté CFM Corporation 2467, 2468 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du CFM Corporation 2467, 2468 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation CFM Corporation 2467, 2468, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le CFM Corporation 2467, 2468 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le CFM Corporation 2467, 2468, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du CFM Corporation 2467, 2468.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le CFM Corporation 2467, 2468. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei CFM Corporation 2467, 2468 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.