Read these instructions bef ore operating the machine MODEL: CDT7 10080220 Operating Instructions 86038220 09/27/07 PRV NO. 98626 UU CARPET EXTRACTOR.
MACHINE DATA LOG/OVERVIEW CADET 86038220 03/16/07 MODEL _____________________________________ __ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRESEN.
TABLE OF CONTENTS CADET 86038220 03/16/07 2 Machine Data Log/Overview. ........................ 1 Table of Contents .......................................... 2 HOW TO USE THIS MANUAL How to use this Manual. ................................ 1-1 SAFETY Important Safety Instructions .
HOW TO USE THIS MANUAL CADET 86038220 03/16/07 This manual contains the f ollowing sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet .
HAZARD INTENSITY LEVEL CADET 86038220 03/16/07 2-2 The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard in tensity identified by signal words - WARNI NG and CAUTION and FOR SAFETY.
GROUNDING INSTRUCTIONS NOTE: In Canad a, th e use o f a tem p orary ad aptor i s no t p ermit ted by the C anad ian El ectri cal Co de PROPER GRO UNDIN G Meta l Scre w A dapto r Grounded Out let Box Fig. A Fig. B Fig. C Tab For Gr oundin g Screw Grounded Outlet Grounding P in A dapto r THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
TECHNICAL SPECIFICATIONS POWER TYPE ELECTRICAL: 115 V, 15 A, 60 HZ ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift –117” (297cm) BRUSH: (1) 15” (38.1 cm.) SOLUTION PUMP: Diaphragm style, internal bypass SOLUTION CAPACITY: 7 gallons (26.
CONTROLS/COMPONENT LOCATIONS 1. Main Handle. Used to pull and maneuver machine. 2. Electrical Cord. 3. Pump Switch. Turns on pump and enables spray. 3 5 4. Brush/Spray sw itch. Turns on brush motor and activates electro-valve to dispense solutio n to floor through jets.
CONTROLS/COMPONENT LOCATIONS 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning t ools. 1 2 3 10 9 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height from storage positio n to variou s carpet heights.
CONTROLS/COMPONENT LOCATIONS 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle. 6 1 2 4 3 5 6 CADET 86038220 03/16/07 3-4.
FILLING OPERATIONS FILLING THE CADET NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solvents, spotter or prespray chemical s in the solutio n tank. Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank before replacing recovery tank.
OPERATIONS STEP 1 Remove electrical co rd an d literature from recovery tank. Fill solution tank (see filling operations, page3-5). Plug cord into grounded ou tlet. STEP 2 Note: Be sure dome is seat ed on recovery tank, and float shut-off is installed correctly.
OPERATIONS Select intermittent or continuous switch setting to turn on brush and start solution spray. The intermittent setting requires the operator to hold the switch in the “on” position with the thumb, and is typically used in small areas where short cleaning passes are made.
CLEANING PROCEDURE Start at wall closest to power outlet. Pull straight back without pushi ng do wn on handle. STEP 1 Release intermittent setting or turn off continuous setting on brush/spray swit ch approximately 1 foot before ending cleaning pass. STEP 2 1ft.
CLEANING PROCEDURE Use right side of machine for cle aning against walls. STEP 5 STEP 6 OFF OFF OFF After cleaning, turn off all controls, return brush to storage position a nd ca refully unplug machine. STEP 7 To speed drying, use a Windblo wer ™ fan.
ACCESSORY TOOL USAGE Turn on Pump and Vacuum Switch. Note: Be sure intermittent/continuous switch is in center (off) position and brush is in storage p osition. Squeeze handle on accessory tool to begin cleaning. STEP 3 STEP 4 STEP 1 Use only one of the following acceptable accessory tools.
MAINTENANCE SERVICE SCHEDULE MAINTENANCE DAILY WEEKLY QUARTERLY Check machine for cord damage * Check recovery dome an d gasket for damage and cleanliness * Check brush – sho uld be clean with no lint or strings attached * Inspect vac shoe for blockage; remove fibers with coat hanger, etc.
MAINTENANCE PERIODIC MAINTENANCE Twice a month, flush a white vinegar sol ution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directe d) through the extractor. This will prev ent build-up of alkaline residue in the system.
MAINTENANCE CADET 86038220 03/16/07 4-3 ! WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEME NT 1. Turn off all switches and unplug machin e. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank bac k to expose the inside of the frame.
MAINTENANCE ! WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. BELT REPLACEMENT 1. Turn off all switches and unplug machin e. 2. Remove recovery tank and brush. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.
MAINTENANCE CADET 86038220 09/27/07 4-5 ! WARNING: ONLY QUALIFIED MAINTENANCE PERS ONNEL ARE TO PERFOR M THE FOLLOWING REPAIRS. SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.
WIRING DIAGRAM 86004480 PRV NO. 41353 86266890 PRV NO. 88655 86268830 PRV NO. 88636 86268450 PRV NO. 88332 CADET 86038220 03/16/07 4-6.
TROUBLESHOOTING CHART PROBLEM CAUSE SOLUTION Is the cord plugged in. Plug in cord. Circuit breaker tripped in building. Reset breaker. Faulty switch. Call for service. No Power, Nothing Runs Faulty power cord or pigtail. Call for service. Vacuum circuit breaker tripped.
MAINTENANCE CADET 86038220 03/16/07 4-8 THIS PAGE INTENTIONALLY LEFT BLANK..
FRAME ASSEMBLY CADET 86038220 03/16/07 5-1 32 28 31 30 B 6 9 33 12 A 19 18 21 34 26 3 4 25 24 14 13 7 15 10 11 22 5 8 20 29 27 16 2 SEE SOLUTION TANK.
FRAME ASSEMBLY CADET 86038220 03/16/07 5- 2 REF PART NO. PART NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 OPEN - - 2 86003620 34341 1 FRAME, CLP FAMILY 3 86004340 39528 1 HOSE ASM, 1.
BRUSH ASSEMBLY CADET 86038220 03/16/07 5-3 31 25 29 30 18 38 39 16 30 34 17 20 37 26 24 11 8 15 3 26 19 6 21 35 28 29 25 17 32 23 14 30 22 4 27 1 16 7 10 12 13 25 40 41 42 43 33 45 36 44 47 25 9 3 2 4.
BRUSH ASSEMBLY CADET 86038220 03/16/07 5-4 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86000730 03110 1 AXLE, ROLLER 2 86227100 04084 1 ADAPTER, BRUSH BRG. 3 86000900 09019 2 BEARING, 1.125ODX.500IDX.375 4 86001100 11045 1 BELT, 180J6 MICRO-V 5 86001140 12514 1 BRUSH, 15L X 3.
PUMP ASSEMBLY CADET 86038220 03/16/07 5-5 PRIOR TO SERIAL NO. 1000166663 3 4 13 10 16 6 5 11 15 19 18 1 20 7 16 21 17 9 2 12 25 26 23 28 24 26 C 20 27 14 8 ( SEE SOLUTION TAN K).
PUMP ASSEMBLY CADET 86038220 03/16/07 5- 6 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86002470 22072 1 COUPLING, 1/4 ANCHOR W/1" HEX 2 86002480 22090 2 CONNECTOR, 1/8FPT X 1/4 .
PUMP ASSEMBLY CADET 86038220 03/16/07 5- 7 29 8 14 27 (SEE SOLUTION 20 C 26 24 26 12 23 2 9 17 21 16 7 20 1 18 19 15 11 5 6 16 10 13 3 TANK) 28 29 28 4 FROM SERIAL NO: 1000166663.
PUMP ASSEMBLY CADET 86038220 03/16/07 5-8 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86032470 22072 1 COUPLING, 1/4 ANCHOR W/1" HEX 2 86002480 22090 2 CONNECTOR, 1/8FPT X 1/4 T.
VACUUM SHOE ASSEMBLY CADET 86038220 03/16/07 5-9 4 7 13 3 10 7 5 6 11 8 2 1 12 11.
VACUUM SHOE ASSEMBLY CADET 86038220 03/16/07 5-10 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86227350 05016 4 ARM, VAC SHOE PARALLEL 2 86234760 27674 1 COVER, ACCESSORY PORT 3 86005810 57245 4 NUT, 1/4-20 HEX NYLOCK SS 4 86006790 70351 2 SCR, 10-32 X 3/8 HHTR W/STAR 5 86275120 70360 4 SCR, 1/4-20 X.
CONTROL PANEL ASSEMBLY CADET 86038220 03/16/07 5-11 12 16 11 4 9 14 5 13 15 19 6 1 18 17 10 7 2 8 3 D 20 21 22 4 23 SEE SOLUTION TAN K.
CONTROL PANEL ASSEMBLY CADET 86038220 03/16/07 5-12 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86001240 14020 1 TERMINAL BLOCK, 115V (3-4-3) 2 86001980 14700 1 BREAKER, 15A 250VAC 5.
SOLUTION TANK ASSEMBLY CADET 86038220 03/16/07 5-13 6 16* 14 18 5* 4 2 8 11* 22 18 15 19* 12 17 23 13B 7 3 29 18 10 1 9 21 20 A B D C 7* 25 24 27* 26* 28* 30* 33 32 34 13A 13 ASM SEE FRAME ASM SEE FRA.
SOLUTION TANK ASSEMBLY CADET 86038220 03/16/07 5-14 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86233140 20041 3 CLAMP, 2.0" WORM GEAR 2 86233150 20042 1 CLAMP, 3/8 HOSE (D-SLOT.
RECOVERY TANK ASSEMBLY CADET 86038220 03/16/07 5-1 5 16 11A 7 1A E 12 9 2 6 17 13 8 4 15 5 10A 12 E 18 14A 3 1B 10B 11B 14B 12.
RECOVERY TANK ASSEMBLY CADET 86038220 03/16/07 5-16 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1A 86002400 20064 1 CLAMP, 2.0" WORM GEAR X .312 10000834 43 1B 86002350 20002 1 CLAMP, 2.0” WORM GEAR 2 86233140 20041 1 CLAMP, 2.0" WORM GEAR 3 86008400 78499 1 CORD, DRAIN HOSE 4 86003110 27816 2 COVER, REC.
SUGGESTED SPARE PARTS CADET 86038220 03/16/07 5-17 PART NO. PRV NO. DESCRIPTION SERIAL # FROM NOTES: 86001140 12514 BRUSH, ASM, 15 IN 86001100 11045 BELT, 180J6 MICRO-V 86000900 09019 BEARING, 1.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Windsor 10080220 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Windsor 10080220 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Windsor 10080220, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Windsor 10080220 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Windsor 10080220, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Windsor 10080220.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Windsor 10080220. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Windsor 10080220 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.