MICROSCOPE COMPONENTS GUIDE Choosing The Ideal UIS2 Optics Components For Y our Equipment 2008-10.
The wide range of Olympus components introduced here allows users in such diverse fields as resear ch, inspection and production to take advantage of the quality , flexibility and outstanding optical performance of the UIS2 Optical System.
CONTENTS 2 EYEPIECES/FILAR MICROMETER EYEPIECE --------------------------------- 33 Widefield eyepieces WHN10x, WHN10 x-H, CROSSWHN10x, WH15 x --------------------- 33 Super widefield eyepieces SWH10x.
light between the objective lens and tube lens, allowing the creation of user -specific or task- specific optical systems. T o establish r eal flexibility with such a system, it is necessary to eliminate the occurrence of coma aberration.
4. Lightening W eight has been r educed to appr oximately 2/3 that of conventional products by using an aluminum objective lens barrel cover . This has the effect of lightening the load on the devices at objective lens up/down, suppressing vibrations by lowering the inertial force at objective lens switching, etc.
5 SYSTEM DIAGRAM 5 6 SHUTTER SHUTTER 5 6 SHUTTER U-AN U-AN360-3 U-AN360IR LG-SF LG-PS2 U-LH100HGAPO U-LH100HG U-LH75XEAPO U-LH100-3 U-LH100L-3 U-LH100IR Super widefield trinocular observation tubes Wi.
6 SYSTEM DIAGRAM MOTORIZED UNIT SYSTEM DIAGRAM BXFM-A SYSTEM DIAGRAM See manual U-D5BDREMC U-D6BDREMC U-D6REMC U-FWO BX-RFAA U-AFA2M-VIS BX-RLAA U-LH100-3 U-LH100L-3 U-FWR Intermediate tubes (Refer to.
7 UIS2/UIS OBJECTIVE LENSES MPL (Plan) FLN-100 BD ■ Objective lens series list ■ Meaning of abbreviations shown on objective lens ■ Objective lens notation ■ Features of objective lens series .
UIS2 OBJECTIVE LENSES 8 Plan Apochr omat MPLAPON series Plan Apochromat objective lenses that correct chromatic aberrations at the highest level. Olympus guarantees* 1 optical performance (wavefront aberration) with a Strehl ratio* 2 of 95% or better.
UIS2 OBJECTIVE LENSES 9 M Plan SemiApochr omat MPLFLN series Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. The lineup consists of 7 objectiv e lenses ranging from 1.25x to 100x, and secures a W.D. of 1mm or longer.
10 UIS2 OBJECTIVE LENSES Long WD M Plan SemiApochr omat (WD: Working Distance) LMPLFLN series Long working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. Suitable with samples having a height difference and in preventing collision, as the working distance is long.
UIS2 OBJECTIVE LENSES 11 Unit: mm M Plan Achr omat MPLN series Plan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5x 0.10 20.0 36 64 50 4.4 98 MPLN 10x 0.25 10.6 18 80 100 2.2 18 MPLN 20x 0.40 1.3 9 111 200 1.1 6.1 MPLN 50x 0.
UIS2 OBJECTIVE LENSES 12 LCD Long WD M Plan SemiApochr omat LCPLFLN-LCD series Perfect objective lens series for observation of LCD panels and other samples through a glass substrate. Aberration correction matched to the glass thickness is accomplished using a correction ring.
13 UIS2 OBJECTIVE LENSES Unit: mm Super Long WD M Plan Achr omat SLMPLN series Plan Achromat objective lenses with high magnification and super long working distance. Three magnifications, 20x, 50x and 100x are available. For 5x or 10x objective lenses, select from the LMPLFLN series.
UIS OBJECTIVE LENSES 14 IR Long WD M Plan Achr omat/IR M Plan Achr omat LMPlan-IR series/MPlan-IR IR objective lenses which compensate for aberrations from visible to near infrared light. Ideal for the observations of semiconductor interiors and the back surface of a chip package as well as CSP bump inspection.
15 UIS2 OBJECTIVE LENSES M Plan SemiApochr omat BD (BD:Brightfield/Darkfield) MPLFLN-BD series Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration.
UIS2 OBJECTIVE LENSES 16 Screw: W26x0.706 Unit: mm MPLFLN 5xBDP 0.15 12.0 36 95.5 50 4.4 59 50 5.3 59 MPLFLN 10xBDP 0.25 6.5 18 83.3 100 2.2 18 100 2.7 18 MPLFLN 20xBDP 0.40 3.0 9 88.5 200 1.1 6.1 200 1.3 6.1 MPLFLN 50xBDP 0.75 1.0 3.6 100.5 500 0.44 1.
UIS2 OBJECTIVE LENSES 17 Long WD M Plan SemiApochr omat BD LMPLFLN-BD series Long working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. Suitable with samples having a height difference and in preventing collision, as the working distance is long.
18 UIS2 OBJECTIVE LENSES M Plan Achr omat BD MPLN-BD series Plan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5xBD 0.10 12.0 36 137 50 4.4 98 MPLN 10xBD 0.25 6.5 18 155 100 2.2 18 MPLN 20xBD 0.40 1.3 9 162 200 1.1 6.
BXFM frame BXFM-F Widely used system that allows use in combination with fiber illumination, motorized revolving nosepiece and telan lens unit. Can easily be integrated into other equipment. Attach to the equipment by rear bolt mounting screw or pillar mounting hole.
MICROSCOPE SYSTEM BXFM 20 BXFM BXFM-F+BXFM-ILH+BXFM-ILHSPU Accommodates the reflected light brightfield/darkfield and fluorescence illuminators. Weight: 3.
MICROSCOPE SYSTEM BXFM 21 ø32 169 (Stroke) 19-49 124 84 208 290 20 40 45 106 187 92.5 Specimen surface BXFM-S combination sample BXFM-F+BXFM-ILHS+TR30-2+U-KMAS+U-LH100L-3 Weight: 5.5kg (exclude objective lens) Unit: mm BXFM-S BXFM-F+BXFM-ILHS Compact focusing unit suitable for building into existing equipment.
MICROSCOPE SYSTEM BXFM 22 U-ST Compact stand Weight: 5kg Unit: mm Weight: 1.8kg 106 73 143 88 ø110 133 ø32 49 133 20 35 ø40 130 503 ø25 Ø32 214~435 622 350 300 180º 90 50.5 30º 250 300 Stands A wide variety of stands are available to suit different applications and purposes.
ILLUMINA TION UNITS 23 Universal r eflected light illuminator BX-URA2 Suitable for observations ranging from brightfield to fluorescence. Six mirror units can be attached to this reflected light illuminator simultaneously. Reflected light illuminator for BF/DF BX-RLA2 ND filters are linked when exchanging between brightfield and darkfield.
ILLUMINA TION UNITS 24 170 (Distance to the light axis) Convex section(2-4) for positioning 3.5 Less than R6 21 82 (Revolving nosepiece relief dimension) 5 5.
LAMP HOUSING & ACCESSORIES 25 Reflected light illuminator for BF U-KMAS Very compact reflected light illuminator with reduced depth. Weight: 1.2kg Unit: mm ø75 88 198 155 21 64 6 21 Unit name Des.
LAMP HOUSING & ACCESSORIES 26 Lamp housings Various different lamp housings are available, for use with different light sources: choose to suit the intended purpose. * If you use the units in your production line, please consult your nearest Olympus representative in your region about the use conditions beforehand.
LAMP HOUSING & ACCESSORIES 27 31.5 (dimensions for installation) Darkfield light excluding tube which is built into the BX-URA2. (42.5) 21 37.5 ø59 ø75 43 Lamp housing accessories For the 100W h.
LAMP HOUSING & ACCESSORIES 28 Unit: mm Unit: mm Weight: 1.6kg Weight: 210g LG-PS2* Light source LG-SF Light guide U-DULHA Double lamp house adapter 8 76 235 251 10 10 126 86 130 ø15 (Light guide mounting position) Groove: Width3, Depth1 10 ø10.1 ø13 ø12 ø25 ø15 30 31 61 25 20 1,000 *The types of model varies by country in use.
OBSERV A TION TUBES 29 Weight: 350g ø60 56 • For attachable video camera adapters, refer to video camera adapters system diagram page (pages 5-6). U-TLU Single port tube with lens U-TLUIR Single port tube with lens for IR Widefield trinocular observation tubes Trinocular observation tubes with widefield of view.
30 OBSERV A TION TUBES 117.223 61.981 139.400 88.000 2.837 70.330 149.081 20 ° 0' 0" 42 ° 0' 0" 95.929 101.929 318.527 328.338 337.718 72.200 Super widefield trinocular observation tubes Trinocular observation tubes with super widefield of view.
Intermediate tubes Various accessories for various observation need. 31 INTERMEDIA TE TUBES & ACCESSORIES 45 42 ø75 ø70 ø138 96 42 Unit: mm Weight: 1.3kg U-ECA Magnification changer 2x Provides 1x and 2x intermediate magnifications. Weight: 1.3kg U-CA Magnification changer Provides 1x, 1.
INTERMEDIA TE TUBES & ACCESSORIES 32 Weight: 1kg U-DP Dual port Use this intermediate tube to divide the light path. Weight: 500g U-DP1xC Dual port 1x Combine with U-DP to obtain a 1x image. Weight: approximately 500g U-EPA2 Eyepoint adjuster Raises eyepoint by 30mm.
EYEPIECES/FILAR MICROMETER EYEPIECE 33 Eyepieces Eyepieces for UIS2 optical system. Filar micr ometer eyepiece U-OSM Used for precise measurement in the field of view. WHN10x Widefield eyepiece WHN10x-H CROSSWHN10x Widefield eyepieces WH15x Widefield eyepiece SWH10x-H MICROSWH10x CROSSSWH10x Super widefield eyepieces (25) 18.
REVOL VING NOSEPIECES U-P4RE Centerable quadruple revolving nosepiece with slider slot for DIC U-P6RE Centerable sextuple revolving nosepiece with slider slot for DIC Weight: 1kg Weight: 1kg 104 (114.4) 38 40 48.2 76.4 ø102.4 116.5 40 47.2 (125.6) 38 87.
REVOL VING NOSEPIECES JAPAN 2A00002 JAPAN U-D6BDRE U-D6BDRE ø102.4 40 48.2 34.8 76.4 104 (111.2) 40 48.2 ø102.4 38 76.4 (114.4) 104 116.5 40 Ø116.5 (125.6) 38 87.6 47.2 U-D6BDRE W26 ✕ 0.706 W20.32 ✕ 0.706 (4) 4 8 ø28.2 +0.2 0 ø30 35 Revolving nosepieces for BF/DF objective lenses Choose from following 3 types.
36 2/3" CCD 1/2" CCD Field of view (F.N.) Projection area Practical field of view (mm) = Projection area (Field Number) Objective lens magnifications 2/3" CCD 1/2" CCD 1/3" CCD U-TV1x-2 1x 11 8 6 U-TV0.63xC 0.63x 17.5 12.7 9.5 U-TV0.
V ideo camera port This port can be attached directly to the trinocular observation tube as well as to the single port tube with lens. VIDEO CAMERA ADAPTERS 37 U-TV1x-2 Video port 1x 22 ø60 28 ø64 V ideo camera mount adapters Allows attachment to video cameras with C, Bayonet, Sony and F mounts.
MOTORIZED UNITS 38 (169) 84 40 45 41 87 (487) 400 64.8 81.5 211.5 86.2 115 80 108 11.8 12 107 Illuminator cable length: 1.800mm Weight: 5.5kg(exclude objective lens) Illuminator cable length: 1.
MOTORIZED UNITS 39 40 50 74.5 115 135 103.5 150 40.5 68.3 25.5 50 46 14 34 U-D5BDREMC Motorized quintuple BD revolving nosepiece with slider slot for DIC U-D6REMC Motorized sextuple revolving nosepiec.
MOTORIZED UNITS 40 Unit: mm 313 108 62.5 45 51 * Consult your Olympus dealer about the motorized focus. Weight: 2.6kg U-AFA2M-VIS Active auto focus unit Featuring an AF laser light source in wavelength 785 nm. The multiple-spots sensor enables the high-speed and stable focusing of specimens with variable height differences.
MOTORIZED UNITS 41 206 310.5 77 133 342.1 334 32.5 56 45 169 2 36 7 92 51 77 54 70 4 75.5 82.3 50 91.5 210 70 100 214 104 33.6 3 BXFMA-F Motorized illumination with power focus A motorized microscope unit for integration with your equipment.
DEEP UL TRA VIOLET OBSER V A TION SYSTEM 42 Deep ultraviolet observation system This module adds a deep ultraviolet (248nm) optical system to a general microscope. An ultra-high resolution observation is executed by using an extremely short wavelength ray.
1. Field Number (F.N.) and Practical Field of View The field number (F.N.) is referred to as the diaphragm size of eyepiece in mm unit which defines the image area of specimen. The diaphragm diameter actually seen through eyepiece is known as the practical field of view (F.
• Total magnification on the video monitor: m (ob) =50 × , M (video camera adapter) is 0.5 × from Figure 1 and monitor magnification is 48.5 × from Figure 3. M (monitor observation) = M (ob) × M ( video camera adapter ) × monitor magnification =50 × 0.
9. Aberrations A difference between an ideal image and an actual image that passes through an optical system is called an “aberration.” 9.1 Requirements for Ideal Image Formation The following three requirements must be satisfied to form an image with no aberration, or an ideal image.
(4) Field curvature An image plane of an object on a plane perpendicular to an optical axis does not always become a plane perpendicular to the optical axis, but it generally becomes a curved plane.
47 OPTICAL TERMINOLOGY 9.4 Strehl ratio When a point light source is observed with an aberration-free optical system and an aberrated optical system , the former concentrates the focal point to a point at the image formation position.
Specifications are subject to change without any obligation on the part of the manufacturer. Illumination devices for microscope have suggested lifetimes.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Olympus 2 0 0 8 - 1 0 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Olympus 2 0 0 8 - 1 0 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Olympus 2 0 0 8 - 1 0, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Olympus 2 0 0 8 - 1 0 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Olympus 2 0 0 8 - 1 0, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Olympus 2 0 0 8 - 1 0.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Olympus 2 0 0 8 - 1 0. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Olympus 2 0 0 8 - 1 0 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.