SVM209-A April, 201 1 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation .
Power MIG® 215XT SAFETY i i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
SAFETY ii ii Power MIG® 215XT FUMES AND GASES can be dangerous. 5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases away from the breathing zone.
Power MIG® 215XT SAFETY iii iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations.
SAFETY iv iv Power MIG® 215XT PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
SAFETY Power MIG® 215XT Electromagnetic Compatibility (EMC) Confor mance P roducts displaying the CE mark are in conformity with European Community Council Directive of 1 5 Dec 2004 on the appro ximation of the laws of the Member Stat es relating to electromagnetic compatibilit y , 2004/1 08/EC .
SAFETY Power MIG® 215XT Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surr ounding ar ea ma y ext end bey ond the boundar ies of the premises.
- MASTER T ABLE OF CONTENTS FOR ALL SECTIONS - I I Power MIG® 215XT Page Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i-vi Installation . .
T ABLE OF CONTENTS - INST ALLA TION SECTION A-1 A-1 Power MIG® 215XT Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1 T echnical Specifications .
INST ALLA TION A-2 A-2 Power MIG® 215XT 75°C Copper Wire 75°C Copper Wire Input Ampere in Conduit in Conduit Input V oltage/ Fuse or Breaker Rating On A WG (IEC) Sizes A WG (IEC) Sizes Frequency (Hz) Size (Super Lag) Nameplate (For lengths (For lengths up to 100 ft.
INST ALLA TION A-3 A-3 Power MIG® 215XT Read entire installation section before starting installation. SAFETY PRECAUTIONS INPUT POWER, GROUNDING AND CONNECTION DIAGRAMS 1.
INST ALLA TION A-4 A-4 Power MIG® 215XT 3. The 208/230 volt 50/60 Hz model Power MIG® is shipped with a 7 ft.(2.1m). input cable and plug con- nected to the welder . 4. Using the instructions in Figure A.2, have a qualified electrician connect a receptacle (Customer Supplied) or cable to the input power lines and the system ground per the U.
INST ALLA TION A-5 A-5 Power MIG® 215XT GUN AND CABLE INST ALLA TION The Magnum 250L gun and cable provided with the POWER MIG® 215XT is factory installed with a liner for .035-.045" (0.9-1.2 mm) electrode and an .035" (0.9 mm) contact tip.
NOTES A-6 A-6 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
T ABLE OF CONTENTS - OPERA TION SECTION B-1 B-1 Power MIG® 215XT Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 Safety Precautions .
OPERA TION B-2 B-2 Power MIG® 215XT Read entire Operation section before operating the POWER MIG® 215XT . ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet cloth- ing. Insulate yourself from work and ground.
OPERA TION B-3 B-3 Power MIG® 215XT PRODUCT DESCRIPTION The Power MIG® 215XT is a complete semiautomatic DC voltage arc welding machine built to meet NEMA specifications. It combines a tapped transformer volt- age power source with a constant speed wire feeder to form a reliable robust performance welding system.
OPERA TION B-4 B-4 Power MIG® 215XT WIRE DRIVE ROLL The drive rolls installed with the POWER MIG® 215XT have two grooves one for .035(0.9mm) wire and the other for .045(1.2mm) wire. Drive roll size is indicated by the stenciling on the exposed side of the drive roll.
OPERA TION B-5 B-5 Power MIG® 215XT T O ST ART THE WELDER T urn the “Power Switch” switch to “ON”. With the desired voltage and wire speed selected, operate the gun trigger for welder output and to energize the wire feed motor .
OPERA TION B-6 B-6 Power MIG® 215XT 3. Press the trigger to feed the wire electrode through the gun and cable. For solid wire cut the electrode within approximately 3/8" (10 mm) of the end of the contact tip [3/4" (20 mm) for Outershield ® ].
OPERA TION B-7 B-7 Power MIG® 215XT INPUT LINE VOL T AGE V ARIA TIONS High Line V oltage — Higher than rated input voltage will result in output voltages higher than normal for a given tap setting. If your input line is high, you may want to select a lower voltage tap than given on the recommended procedure chart.
NOTES B-8 B-8 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
T ABLE OF CONTENTS - ACCESSORIES SECTION C-1 C-1 Power MIG® 215XT Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1 Drive Roll Kits .
ACCESSORIES C-2 C-2 Power MIG® 215XT DRIVE ROLL KITS Refer to T able C.1 for various drive roll kits that are available for the POWER MIG® 215XT . The item in Bold is supplied standard with the POWER MIG® 215XT .
ACCESSORIES C-3 C-3 Power MIG® 215XT MAGNUM 250LX PUSH-PULL GUN AND PUSH PULL ADAPTER For heavier duty aluminum applications when use of large 16 pound aluminum spools of wire are desired the follow- ing push pull gun and adapter kit are available.
ACCESSORIES C-4 C-4 Power MIG® 215XT MAKING A WELD WITH THE SPOOL GUN ADAPTER KIT AND SPOOL GUN INST ALLED In either toggle switch position, closing either gun trigger will cause the electrode of both guns to be electrically “HOT”. Be sure unused gun is posi- tioned so electrode or tip will not contact metal case or other metal common to work.
T ABLE OF CONTENTS - MAINTENANCE SECTION D-1 D-1 Power MIG® 215XT Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D-1 Safety Precautions .
MAINTENANCE D-2 D-2 Power MIG® 215XT • Be sure the nozzle insulator is fully screwed onto the gun tube and does not block the gas holes in the diffuser . • Slip the appropriate gas nozzle onto the nozzle insulator . Either a standard .50" (12.
7. Screw the gas diffuser onto the end of the gun tube and securely tighten. Be sure the gas diffuser is cor- rect for the liner being used. (See table and diffuser stencil.) 8. Tighten the set screw in the side of the gas diffuser against the cable liner using a 5/64" (2.
MAINTENANCE D-4 D-4 Power MIG® 215XT GUN HANDLE DISASSEMBL Y The internal parts of the gun handle may be inspected or serviced if necessary . The gun handle consists of two halves that are held together with a collar on each end.
MAINTENANCE D-5 D-5 Power MIG® 215XT 1. Case Front Assembly 2. Rear Panel Assembly 3. Center Assembly 4. Wire Drive Assembly 5. Base & Power Component Assembly 6.
NOTES D-6 D-6 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
T ABLE OF CONTENTS-THEOR Y OF OPERA TION SECTION E-1 E-1 Power MIG® 215XT Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E-1 Input Power Circuit .
THEOR Y OF OPERA TION E-2 E-2 Power MIG® 215XT INPUT LINE VOL T AGE, MAIN TRANSFORMER, VOL T AGE SELECT OR SWITCH AND BAFFLE MOUNTED DIODE BRIDGE T h e s i n g l e p h a s e i n p u t p o w e r i s c o n n e c te d t o t h e Power MIG® 215XT through a line switch located on the front panel.
THEOR Y OF OPERA TION E-3 E-3 Power MIG® 215XT OUTPUT RECTIFICA TION, CONT ACTOR AND CONTROL BOARD The AC voltage developed on the secondary winding is applied, through the selector switch and output contactor , to the output rectifier bridge.
THEOR Y OF OPERA TION E-4 E-4 Power MIG® 215XT CONTROL BOARD, GUN TRIGGER AND WIRE DRIVE MOT OR When the control board receives an activation command from the trigger circuit the control board supplies 12VDC which activates the gas solenoid and output contactor .
THEOR Y OF OPERA TION E-5 E-5 Power MIG® 215XT P R O T E C T I V E D E V I C E S A N D C I R C U I T S THERMAL AND OVERLOAD PROTECTION Th e Pow er MIG ® 215 XT has two bui lt- in pro tec tiv e th erm os tat s tha t res po nd to ex ce ssi ve te mpe ra tur es.
NOTES E-6 E-6 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master .
T ABLE OF CONTENTS - TROUBLESHOOTING AND REP AIR F-1 F-1 Power MIG® 215XT T roubleshooting and Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .F-1 How to Use T roubleshooting Guide .
TROUBLESHOOTING AND REP AIR F-2 F-2 Power MIG® 215XT This T roubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below . Step 1. LOCA TE PROBLEM (SYMPTOM). Look under the column labeled “PROBLEM (SYMPTOMS)”.
TROUBLESHOOTING AND REP AIR F-3 F-3 Power MIG® 215XT Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections. T o avoid prob- lems when troubleshooting and replacing PC boards, please use the following procedure: 1.
OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
OUTPUT PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not und.
FUNCTION PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not u.
WIRE FEEDING PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do n.
WELDING PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not un.
WELDING PROBLEMS Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AREAS OF MISADJUSTMENT(S) RECOMMENDED COURSE OF ACTION If for any reason you do not un.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
X8 X7 X6 X5 X4 X3 X2 FIGURE F .1 – OUTPUT SELECTOR SWITCH TERMINALS MAIN TRANSFORMER TEST (continued) TROUBLESHOOTING AND REP AIR F-12 F-12 Power MIG® 215XT W ARNING PROCEDURE THE ON/OFF POWER SWITCH will be “hot” during these tests. NOTE: Secondary voltages will vary proportionately with the primary input voltage.
X1 FIGURE F .2 – LEAD X1 X9 X10 FIGURE F .3 – LEAD X9 & X10 MAIN TRANSFORMER TEST (continued) TROUBLESHOOTING AND REP AIR F-13 F-13 Power MIG® 215XT Return to Section TOC Return to Section TO.
T ABLE F .1 – TEST POINTS MAIN TRANSFORMER TEST (continued) 12. If ALL the voltages tested are incorrect or miss- ing, test for correct nameplate input voltage between the H1 lead at the ON/OFF POWER SWITCH to H2 or H3 at the reconnect panel. V oltage tested will vary depending on input voltage connection.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Black Tach J11 J11 Black Arm White Arm Blue Tach Red Tach FIGURE F .4 – PLUG J4 WIRE DRIVE MOTOR AND T ACHOMETER FEEDBACK TEST (continued) PROCEDURE NOTE: POLARITY MUST BE OBSERVED FOR THESE TESTS. T est for correct wire drive motor armature voltage.
5. Make the following voltage tests: a. Turn the machine OFF between each test. b. Carefully insert the meter probes into the lead side of plug J4. See Figure F .
TEST FOR FEEDBACK VOL T AGE T O CONTROL BOARD 1. Disconnect the main AC input power to the machine. 2. Locate plug J4 and the tach leads. See Figure F .5. 3. Connect main input power to the machine. 4. Make the following voltage tests: a. Turn the machine OFF between each test.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Front - + Negative Lead FIGURE F .6 – RECTIFIER TEST POINTS OUTPUT BRIDGE RECTIFIER TEST (continued) PROCEDURE 1. Remove input power to the Power MIG® 215XT machine. 2. Using the 3/8” nutdriver , remove the left case side. 3. Locate and disconnect the negative lead from the output rectifier bridge assembly .
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
107A 106C 106B Output Contactor FIGURE F .7 – CONT ACTOR TERMINALS AND LEADS CONT ACTOR TEST (continued) TROUBLESHOOTING AND REP AIR F-22 F-22 Power MIG® 215XT PROCEDURE 1. Remove the input power to the Power MIG® 215XT machine. 2. Using the 5/16” Nutdriver , remove the tool tray .
This is a typical DC output voltage waveform generated from a properly operating machine. Note that each vertical division represents 10 volts and that each horizontal division rep- resents 5 milliseconds in time. The machine was loaded with a resistance grid bank.
This is a typical DC output voltage waveform generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division rep- resents 1.0 milliseconds in time. No te : Scope probes connected at machine output terminals: (+) probe to electrode, (-) probe to work.
This is NOT a typical DC output volt- age waveform. One output diode is not functioning. Note the increased ripple content. One diode was discon- nected to simulate an open or non- functioning output diode. Each vertical division represents 20 volts and each horizontal division represents 5 mil- liseconds in time.
This is NOT a typical DC output volt- age waveform. The output capacitors are not functioning. Note the lack of “filtering” in the output waveform. The output capacitor bank was disconnect- ed. Each vertical division represents 20 volts and each horizontal division represents 5 milliseconds in time.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
DEPRESS L O C K I N G T A B O N MOUNTING PIN FIGURE F .8 – CONTROL BOARD MOUNTING PINS CONTROL BOARD REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Remove power to the machine. 2. Using a 5/16” nutdriver , remove the three screws securing the tool tray .
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Wire Drive FIGURE F .9 – WIRE DRIVE LOCA TION WIRE DRIVE MOTOR REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Remove power to the machine. 2. Lift cover to gain access to the wire drive. See Figure F .9. 3. Using a pair of pliers, disconnect the gas hose from the bottom of the wire drive.
Gas Hose 9/16" Bolt 5/16" Sheet Metal Screws FIGURE F .10 – WIRE DRIVE HOSE & LEAD LOCA TION 5/16" Monuting Screws FIGURE F .1 1 – MOUNTING SCREW LOCA TIONS WIRE DRIVE MOTOR REM.
WIRE DRIVE MOTOR REMOV AL AND REPLACEMENT PROCEDURE (continued) 1. Place the new wire drive assembly into its prop- er position. 2. Connect plug J4. 3. Maneuver assembly back into its original posi- tion. 4. Replace all mounting screws previously removed.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
OUTPUT DIODE BRIDGE RECTIFIER FIGURE F .12 – OUTPUT DIODE BRIDGE RECTIFIER LOCA TION OUTPUT DIODE BRIDGE RECTIFIER REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Using a 3/8” nutdriver , remove the left side of the case wraparound cover .
5/16" Mounting Bracket Mounting Bolts 1/2" Rectifier Mounting Bolts Mounting Bracket FIGURE F .13 – OUTPUT DIODE BRIDGE RECTIFIER MOUNTING BRACKET OUTPUT DIODE BRIDGE RECTIFIER REMOV AL AN.
NOTES F-36 F-36 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Maste.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
LOWER RIGHT CASE WRAP AROUND COVER CAP ACIT OR BANK ASSEMBL Y FIGURE F .14 – CAP ACITOR BANK LOCA TION OUTPUT CAP ACITORS REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Using a 3/8” nutdriver , remove the lower right side case wraparound cover .
} { 3/8" Nuts & Lock washers (3 places) Lead Mounting Bolts FIGURE F .15 – MOUNTING SCREW / BOL T LOCA TIONS OUTPUT CAP ACITORS REMOV AL AND REPLACEMENT PROCEDURE (continued) TROUBLESHOOTIN.
NOTES F-40 F-40 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Maste.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
Main T ransformer 1/2" Mounting Bolts FIGURE F .16 – MAIN TRANSFORMER LOCA TION MAIN TRANSFORMER REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Using a 3/8” nutdriver , remove both sides of the case wraparound cover . 2. Using a 5/16” nutdriver , remove the tool tray .
X10 X9 104B 104C H1B FIGURE F .17 – LEADS X9, X10, 104B, 104C, & H1B MAIN TRANSFORMER REMOV AL AND REPLACEMENT PROCEDURE (continued) 15. Carefully maneuver the main transformer out the left side of the machine. NOTE: T wo people may be needed to maneuver the main transformer out of the machine.
X8 X7 X6 X5 X4 X3 X2 FIGURE F .18 – LEADS SWITCH LEADS Front - + 121 1 18 FIGURE F .19 – LEAD 121 & 1 18 MAIN TRANSFORMER REMOV AL AND REPLACEMENT PROCEDURE (continued) TROUBLESHOOTING AND REP.
5/16" Nut REAR ACCESS P ANEL FIGURE F .20 – REAR ACCESS P ANEL 230V 208V 4 L1 L2 Lead 1 18 FIGURE F .21 – REAR ACCESS P ANEL (CLOSE-UP) MAIN TRANSFORMER REMOV AL AND REPLACEMENT PROCEDURE (co.
NOTES F-46 F-46 Power MIG® 215XT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Maste.
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
REAR 5/16" Bolts } } Fan Mounting Band 1 1/32" Mounting Nuts Fan Blade Fan Motor FIGURE F .22 – F AN MOUNTING BOL TS F AN BLADE / MOT OR REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Using a 3/8” nutdriver , remove the lower right side of the case wraparound cover .
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty .
107A 106C 106B Output Contactor FIGURE F .23 – OUTPUT CONT ACTOR LEADS OUTPUT CONT ACTOR REMOV AL AND REPLACEMENT PROCEDURE (continued) PROCEDURE 1. Using a 5/16” nutdriver , remove the three screws securing the tool tray . 2. Locate the output contactor .
7/16" Mounting Bolts FIGURE F .24 – OUTPUT CONT ACTOR MOUNTING BOL TS OUTPUT CONT ACTOR REMOV AL AND REPLACEMENT PROCEDURE (continued) TROUBLESHOOTING AND REP AIR F-51 F-51 Power MIG® 215XT Re.
TROUBLESHOOTING AND REP AIR F-52 F-52 Power MIG® 215XT RETEST AFTER REP AIR INPUT IDLE AMPS AND W A TTS OPEN CIRCUIT VOL T AGE WIRE SPEED RANGE Input V olts/Herts 230/60 Maximum Idle Amps 2.0 Maximum Idle Watts 150 35 - 40 VDC 50 - 700 IPM (1.27 - 17.
T ABLE OF CONTENTS - DIAGRAM SECTION G-1 G-1 Power MIG® 215XT Electrical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G-1 Wiring Diagram (L12184-1) .
ElEcTrical DiaGramS G-2 pOWEr miG® 215XT WiriNG DiaGram - cOmplETE machiNE - l12184-1 POW ER MIG 2 15X T (208/ 220/ 230 V) FOR COD E 1 1521 J1 C AVIT YN U M BE RING SE QUENCE (COMPONENT S IDE OF P .C. B OARD) J2 NOTES: N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS.
ElEcTrical DiaGramS G-3 pOWEr miG® 215XT SchEma Tic - cOmplETE machiNE - l12308-1 pG1 J1 , J1 4 CAVITY NUM BERI NG SEQ UE N CE ( COMPONENT S IDE OF P.
ElEcTrical DiaGramS G-4 pOWEr miG® 215XT SchEma Tic - cOmplETE machiNE - l12308-1 pG2 J1 , J1 4 CAVITY NUM BERI NG SEQ UE N CE ( COMPONENT S IDE OF P.
ElEcTrical DiaGramS G-5 pOWEr miG® 215XT SchEma Tic - cONTrOl bD - G4414 pG1 G-5 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
ElEcTrical DiaGramS G-6 pOWEr miG® 215XT SchEma Tic - cONTrOl bD - G4414 pG2 G-6 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
ElEcTrical DiaGramS G-7 pOWEr miG® 215XT SchEma Tic - cONTrOl bD - G4414 pG3 G-7 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lincoln Electric 11521 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lincoln Electric 11521 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lincoln Electric 11521, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lincoln Electric 11521 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lincoln Electric 11521, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lincoln Electric 11521.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lincoln Electric 11521. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lincoln Electric 11521 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.