Operation/Reference Guide Custom Panel I nterfaces NXP-CPI16 NetLinx Custom Panel Interface Last Rev ised: 1/13/ 2009.
AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with .
Table of Contents i NXP-CPI16 NetLinx Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ..........................
.
Produc t Info rma tion 1 NXP-CPI16 NetLinx Custom Panel Interfa ce Product Information The AMX NXP-CPI16 is a NetLinx panel device that allows sys tem integrators to connect switches, indicators, and rotary encoders to a NetLinx control system.
2 NXP-CPI16 NetLinx Custom Panel Interfa c e Specifications The table below lists the NXP-CPI1 6 specifications. NXP-CPI16 Specifications Power Requirement 12 VDC (300 m A ma x.
3 NXP-CPI16 NetLinx Custom Panel Interfa ce Input and Output Conne ctors T o install the NXP-CPI16, connect r ibbon cables or a PC b oard to one or more of the h eaders. The table belo w shows the pinouts for the two 20-pin headers. Quadrature Connectors The table below lists th e connector pinouts for the quadrature connector .
4 NXP-CPI16 NetLinx Custom Panel Interfa c e Quad ratur e Input s By default, the quadrature inputs e xpect the phase relationship, shown in FIG. 2, for a clockwise rotation of the encoder to generate a positiv e level change. If the phase relationship does not match the e xample, a clockwise rotation will generate a negati ve lev e l change.
Progra mming 5 NXP-CPI16 NetLinx Custom Panel Interfa ce Programming There are two modes of Channel A ssign ments: Discrete Outp ut and Def au lt Mode.
Send_Commands Use the Send_Commands listed in the table belo w to program the NXP-CPI16. Send_Commands BMODE Configures either set of 8 outp uts as an 8-segment bar- graph display .
7 NXP-CPI16 NetLinx Custom Panel Interfa ce Send_Commands (Cont.) LV L _ S Z Sets the size (data type) of the value that will be used by the NXP-CPI16 when receiving and sending LEVEL messages. The default is byte (8-bits), which yields a rang e of 0 - 2 55 for the level value.
8 NXP-CPI16 NetLinx Custom Panel Interfa c e The NXP-CPI16 uses input channels to rep ort user input on the contacts or switches attached to the input terminals. Output channels are used to turn on the lamp or LED display de vice s to indicate the b utton status to the user .
9 NXP-CPI16 NetLinx Custom Panel Interfa ce Each of the two 20-pin connectors is assign ed a group of 8 input and output channels. The table belo w sho ws the relation of input and output channels in the ST A TUS modes. The NXP-CPI16 may be configured to default to ST A TUS- ON mode using the follo wing method.
10 NXP-CPI16 NetLinx Custom Panel Interfa c e.
System Worksheets 11 NXP-CPI16 NetLinx Custom Panel Interfa ce System Worksheets Header 1 Header 2 Dealer ID Date Dealer PO Number Job SO Number Description Serial Number Rev Number Device Number CH1 .
CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 Out In Out In Out In Out In Out In Out In Out In Out In 9 10 11 12 Ground Po w e r Ground Ground 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20.
.
1/09 © 2009 AM X. All right s reserved . AMX and the AMX logo ar e registered trademarks of AMX. A MX reserves t he right to alter spec ific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AMX NetLinx Custom Panel Interface NXP-CPI16 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AMX NetLinx Custom Panel Interface NXP-CPI16 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AMX NetLinx Custom Panel Interface NXP-CPI16, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AMX NetLinx Custom Panel Interface NXP-CPI16 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AMX NetLinx Custom Panel Interface NXP-CPI16, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AMX NetLinx Custom Panel Interface NXP-CPI16.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AMX NetLinx Custom Panel Interface NXP-CPI16. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AMX NetLinx Custom Panel Interface NXP-CPI16 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.