www.Fisher.com D103048X012 Type 3 024C D iaphragm A ctuator Contents Introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scope of Manual 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . Description 1 . . . . . . . . . .
3024C Actuator Instruction Manual Form 5760 March 2007 2 Figure 2. Schematic of Type 3024C 1Q57489 AIRĆTOĆCLOSE (A TC) AIRĆTOĆOPEN (A TO) an ATC (air-to-close) actuator and an ATO (air-to-open) actuator.
3024C Actuator Instruction Manual Form 5760 March 2007 3 Table 2. Additional Specifications (Action Air-to-Close) Size Spring Set/ Quantity T ravel Spring Range Effective Diaphragm Area (Note 1) Maximum Output Thrust (Maximum Actuator Stem Force) (Note 2) Quantity mm Inch Bar Psig cm 2 Inches 2 N Lb 217/3 0.
3024C Actuator Instruction Manual Form 5760 March 2007 4 Table 3. Additional Specifications (Action Air-to-Open) Size Spring Set/ Quantity T ravel Spring Range Effective Diaphragm Area (Note 1) Maximum Output Thrust (Maximum Actuator Stem Force) (Note 2) Quantity mm Inch Bar Psig cm 2 Inches 2 N Lb 217/3 0.
3024C Actuator Instruction Manual Form 5760 March 2007 5 Table 4. Handwheel Specifications ACTU- AT O R SIZE HAND- WHEEL DIAMETER TURNS PER mm/INCH TRA VEL RIM FORCE (1,2) HAND- WHEEL OUTPUT FORCE SIZE mm In. mm In. N lb N lb 30 and 30E 200 7.87 0.24 6.
3024C Actuator Instruction Manual Form 5760 March 2007 6 Figure 4. Actuator Mounting Components for Assembly with a Valve W8484-1 dimensions. Key numbers referenced in the following steps are shown in figures 8 and 9.
3024C Actuator Instruction Manual Form 5760 March 2007 7 g. Slowly decrease and then increase the diaphragm pressure several times stroking the valve from the lower end to the upper end of the spring range. h. Apply air pressure to the diaphragm until the valve is in the closed position.
3024C Actuator Instruction Manual Form 5760 March 2007 8 W ARNING Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations: D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations to avoid personal injury.
3024C Actuator Instruction Manual Form 5760 March 2007 9 For a Type 3024C Air-to-Close Actuator (figure 8) a. Lift off the upper diaphragm casing (key 16) and casing spacer (key 29) and seal ring (key 30) if fitted (see figure 14). b. Using a strap wrench or soft-jawed vice, hold the actuator stem (key 8) and remove the travel stop nut (key14).
3024C Actuator Instruction Manual Form 5760 March 2007 10 Figure 5. Type 3024C Spring Arrangements SIZE 30 AND 30E 3 SPRINGS SIZE 30 AND 30E 5 SPRINGS SIZE 30 AND 30E 7 SPRINGS SPRING LOCA TOR SPRING .
3024C Actuator Instruction Manual Form 5760 March 2007 11 diaphragm without moving either the upper diaphragm casing or the diaphragm plate so that the diaphragm holes line up with those in the casings. d. Lift off the upper diaphragm casing and remove the springs.
3024C Actuator Instruction Manual Form 5760 March 2007 12 the eight hex cap screws (key 113) that hold the assembly to the yoke. 2. Loosen the lock (key 115) that secures the drive screw assembly (key 103). 3. Remove the retaining ring (key 110) and screw out the drive screw assembly (key 103).
3024C Actuator Instruction Manual Form 5760 March 2007 13 Figure 6. Actuator Dimensions 1Q57491 D E F C AR (ACTUA TOR REMOV AL) D Actuator Dimensions Refer to figures 6 and 7 and table 5 for dimensions.
3024C Actuator Instruction Manual Form 5760 March 2007 14 Figure 7. Actuator Dimensions with Handwheel 1Q57490 REVERSEĆACTING DIRECT ĆACTING H S H S J S J S M M Parts Ordering Each actuator has a serial number stamped on the nameplate (figure 2 and key 34 on figures 8 and 9).
3024C Actuator Instruction Manual Form 5760 March 2007 15 Figure 8. Direct-Acting Actuator (Air-to-Close) 3Q57478.
3024C Actuator Instruction Manual Form 5760 March 2007 16 Figure 9. Reverse-Acting Actuator (Air-to-Open) 3Q57479.
3024C Actuator Instruction Manual Form 5760 March 2007 17 Parts List Note For part numbers not shown, contact your Emerson Process Management sales office.
3024C Actuator Instruction Manual Form 5760 March 2007 18 Figure 10. Side-Mounted Handwheel for Type 3024C Actuators 1Q57480 Figure 11. Adjustable Up Travel Stop for Sizes 30 to 40E 3Q57478.
3024C Actuator Instruction Manual Form 5760 March 2007 19 Figure 12. Adjustable Up Travel Stop for Sizes 45 to 45E 3Q57478 Figure 13. Casing Spacer Detail for ATO Figure 14.
3024C Actuator Instruction Manual Form 5760 March 2007 20 Emerson Process Management Marshalltown, Iowa 50158 USA Cernay 68700 France Sao Paulo 05424 Brazil Singapore 128461 www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson Process Management 3024C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson Process Management 3024C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson Process Management 3024C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson Process Management 3024C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson Process Management 3024C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson Process Management 3024C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson Process Management 3024C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson Process Management 3024C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.