Part No. F40BP73860000 Form No. BP7386 Model No.: CF3400 READ AND SA VE THESE INSTRUCTIONS Net Weight: Lbs. CORSAIR ™ 44” or 52” Ceiling F an Owner's Manual CF3400AP Antique P ewter CF3400ORH Oil R ubbed Br onze with Highlights Model Number s 24” - 21.
WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference.
3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
3. Pull the electrical supply wires through the opening on the back side of the hanger bracket for installation of the fan’s hanger ball. 4. T o prevent scratching the fan assembly , secure the upper motor cover onto a blade flange with masking tape.
6. Carefully slide the motor ring up the motor housing and position the ring so that the reverse switch slot in the ring is in the correct position (Figure 5). NOTE: Careful not to scratch ceiling fan assembly while positioning the motor ring in place.
BLADE (Sold Separately) #10-32 x .75" OV AL HEAD SCREW (3 per blade assembly) BLADE MEDALLION MEDALLION BOSS (3 per medallion) Figure 6 2. Assemble the remaining blade per previous instructions. NOTE: T ake care not to scratch fan blades during installation.
Figure 10 Using Y our Ceiling F an IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the controls. 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box or circuit breaker panel.
T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose electrical connections 2.
10 Model No.: CF3400 Part Numbers Key Model No. Model No. N o . Description CF3400AP00 CF3400ORH00 1 Ceiling Plate (1) 763816-AP 763816-ORH 2 Hanger Bracket Assembly (1) 760732 760732 3 Hangerball Assembly (1) 763949 763949 4 Reverse Switch (1) 763898 763898 5 Axillary Capacitor 8.
11 Model No.: CF3400 R epair Par ts 7 11 4 5 8 10 9 3 12 6 1 2 4 0 3 2 1 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be found on a label attached to the top housing.
Part No. F40BP73860000 Printed in China 1 1/09 Form No. BP7386 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W . Florissant • St. Louis, MO 63136 Model No.
READ AND SA VE THESE INSTRUCTIONS Installa tion Instr uction on New CSA Hanging De vice Always properly install the ceiling fan mounting plate to a structural ceiling joist that is capable of reliably supporting at least 50 pounds. INST ALLA TION INSTRUCTIONS 1.
7. Insert the ceiling fan support cable from the fan through the brass nut and reinstall the machine screw. Tighten the machine screw securely (Figure 5).
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson CF3400AP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson CF3400AP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson CF3400AP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson CF3400AP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson CF3400AP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson CF3400AP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson CF3400AP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson CF3400AP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.